• 제목/요약/키워드: Building Layer

검색결과 807건 처리시간 0.023초

LIDAR 자료를 이용한 수치지도 건물레이어 갱신 (Building Layer Update of Digital Map using LIDAR Data)

  • 김성삼;구신회;김원석;유환희
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.411-417
    • /
    • 2006
  • As NGIS project has been implemented in 1995 and effectiveness of spatial information increased, Digital maps serve several purpose in administrative, living, and industrial fields. But, Digital maps have many differences with real world information and difficulties in application of managing urban facilities due to high update cost and long generation period. In this study, We suggest methodology to update a building layer of digital map in urban area as regenerating a building layer by detection of changed buildings in the existing digital map anf extraction using LIDAR data and Aerial images, more easier to acquire data and available to guarantee accuracy. Experimental results are expected to applied for constructing 3D urban model in a broad expensive urban area.

  • PDF

BACnet/ZigBee 프로토콜 기반의 조명제어시스템 (BACnet/ZigBee-based Lighting Control System)

  • 전유진;박태진;박동규;홍승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.117-119
    • /
    • 2006
  • BACnet(Building Automation and Control networks) is a standard data communication protocol designed specifically for building automation and control systems. BACnet provides five options for datalink layer protocols and these five datalink layer options can be applied with various transmission media. Recently wireless technology prevails in automation area. ZigBee is a standard protocol based on IEEE 802.15.4 for low-speed wireless communication network. In this study, we propose a BACnet/ZigBee model that uses ZigBee wireless technology in a BACnet communication network system as a wireless datalink layer protocol. We also applied this model to a lighting control system to evaluate the feasibility of proposed technology. The technology proposed in this paper can extend the application of BACnet not only for building automation but also for home automation by taking the advantages of ZigBee wireless communication technology in BACnet communication network systems.

  • PDF

Updates to the wind tunnel method for determining design loads in ASCE 49-21

  • Gregory A. Kopp
    • Wind and Structures
    • /
    • 제37권2호
    • /
    • pp.163-178
    • /
    • 2023
  • The paper reviews and discusses the substantive changes to the ASCE 49-21 Standard, Wind Tunnel Testing for Buildings and Other Structures. The most significant changes are the requirements for wind field simulations that utilize (i) partial turbulence simulations, (ii) partial model simulations for the flow around building Appurtenances, along with requirements for determining wind loads on products that are used at multiple sites in various configurations. These modifications tend to have the effect of easing the precise scaling requirements for flow simulations because it is not generally possible to construct accurate models for small elements placed, for example, on large buildings at the scales typically available in boundary layer wind tunnels. Additional discussion is provided on changes to the Standard with respect to measurement accuracy and data acquisition parameters, such as duration of tests, which are also related to scaling requirements. Finally, research needs with respect to aerodynamic mechanisms are proposed, with the goal of improving the understanding of the role of turbulence on separated-reattaching flows on building surfaces in order to continue to improve the wind tunnel method for determining design wind loads.

공동주택 층간 이음부 균열 보수공법에 대한 하자분쟁 분석 (An Analysis of Defect Dispute about Inter-Layer Crack Repair Method on Apartment Houses)

  • 이태형;정용기;최병주;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.146-147
    • /
    • 2017
  • Recently, as the living standards of residents in apartment houses continued to improve, the dispute of post management have also increased. one of the Issue, Concrete Cracks comprised high percentage of dispute. Especially, between criteria the cost of repairing defect and the judgement of defect isn't clear, they are a lot of dispute in this regard. Even though lots of the criteria about Inter-layer crack is existed by judging defects, In a court, they are judging their own criteria about Inter-layer crack. The purpose of this study is to compare and analyze Defect Judement Standard both MOLIT and Court, and to provide the Improvement for Defect Judgement and Repair Method of Inter-layer concrete crack.

  • PDF

멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구 (A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance quality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구 (A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance duality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

기밀성 차단제를 이용한 탄산화 억제대책 (Effect of a protective Layer on the Level of Carbonation Resistance of Concrete)

  • 김경훈;어량량;허영선;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.27-28
    • /
    • 2013
  • This study investigates the effect of a protective layer on the level of carbonation resistance of concrete. For the protective layer, a PE film, bubble sheets, double layered bubble sheets and styroform were placed in a mold before placing the concrete. In addition, PE film was retrofitted by attaching on the surface of the substrate concrete with a glue. Results showed that the carbonation depths of the control concrete were 4.6 mm and 5.2 mm at one week and two weeks exposure in an accelerated carbonation chamber, whereas the concrete with all types of protective layer except PE flim did not allow the ingress of carbon dioxide during the same period.

  • PDF

비경화성 점착 방수제와 보강메쉬를 이용한 지하 외방수 공법에 관한 연구 (A Study on the Outside Waterproof Method of Ground using Wire-mesh and Non-hardening Viscosity WaterproofBusiness)

  • 문유석;이신춘;권기주;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.213-217
    • /
    • 2009
  • Underground structures are built into concrete like a architecture and public works. Concrete has watertightness as such, But buildings are leaking from the cracks. Recently, construction method do a lot of close construction in the downtown area. So architects are using the method for the outer layer of a two-layer wall to save spaces. They have been using Top-down method and waterproof agent method and others to outer layer of a two-layer wall method. But, There are many leakage in underground structure from lack on requirements performance of materials. Therefore, I hope to test the outside Waterproof Method of Ground using Wire-mesh and Non-hardening Viscosity Waterproof. In addition to, I wish to apply as outside waterproof method for the section for the outer layer of a two-layer wall in underground structure.

  • PDF

국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포 (Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea)

  • 김기연
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.

Study on the performance indices of low-strength brick walls reinforced with cement mortar layer and steel-meshed cement mortar layer

  • Lele Wu;Caoming Tang;Rui Luo;Shimin Huang;Shaoge Cheng;Tao Yang
    • Earthquakes and Structures
    • /
    • 제24권6호
    • /
    • pp.439-453
    • /
    • 2023
  • Older brick masonry structures generally suffer from low strength defects. Using a cement mortar layer (CML) or steel-meshed cement mortar layer (S-CML) to reinforce existing low-strength brick masonry structures (LBMs) is still an effective means of increasing seismic performance. However, performance indices such as lateral displacement ratios and skeleton curves for LBMs reinforced with CML or S-CML need to be clarified in performance-based seismic design and evaluation. Therefore, research into the failure mechanisms and seismic performance of LBMs reinforced with CML or S-CML is imperative. In this study, thirty low-strength brick walls (LBWs) with different cross-sectional areas, bonding mortar types, vertical loads, and CML/S-CML thicknesses were constructed. The failure modes, load-carrying capacities, energy dissipation capacity and lateral drift ratio limits in different limits states were acquired via quasi-static tests. The results show that 1) the primary failure modes of UBWs and RBWs are "diagonal shear failure" and "sliding failure through joints." 2) The acceptable drift ratios of Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP) for UBWs can be 0.04%, 0.08%, and 0.3%, respectively. For 20-RBWs, the acceptable drift ratios of IO, LS, and CP for 20-RBWs can be 0.037%, 0.09%, and 0.41%, respectively. Moreover, the acceptable drift ratios of IO, LS, and CP for 40-RBWs can be 0.048%, 0.09%, and 0.53%, respectively. 3) Reinforcing low-strength brick walls with CML/S-CML can improve brick walls' bearing capacity, deformation, and energy dissipation capacity. Using CML/S-CML reinforcement to improve the seismic performance of old masonry houses is a feasible and practical choice.