• Title/Summary/Keyword: Building Integrated Photovoltaic(BIPV)

Search Result 127, Processing Time 0.026 seconds

The Operating Characteristics of 3kW BIPV System (3kW BIPV시스템의 운전특성)

  • Kim J.H.;Park J.M.;Choi Y.O.;Choi S.J.;Cho G.B.;Baek H.R.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.552-554
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. But, there are many generation differences according to the exterior environmental facts(solar cell array, design and installation condition of interactive inverter system) Therefore, it is difficult to optimum design. Consequently in advance design system, we experiment 3kW BIPV(Building Integrated PV) generation. We concrete PV system efficient application of variable. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. This research is a basic study for application of building integrated photovoltaic system for building

  • PDF

The Advanced Case Study for Investigation on Application of BIPV on Tall Building (초고층빌딩의 BIPV 적용성 검토를 위한 선진 사례 조사)

  • Lee, Jong-Min;Seok, Ho-Tae;Yang, Jeong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.155-160
    • /
    • 2009
  • The increasingly high prices for oil, the exhaustion of fossil fuels as well as concern about global warming are driving rapid growth of alternative sources of energy in the world. The active solution for global environment and exhaustion of energy sources is to develop and popularize the technologies to use natural energy such as sunlight, wind, and water. PV(Photovoltaic) modules are efficient devices that has been considered a logical material for use in buildings. Recent advanced BIPV(Building Integrated PV) technology have rapidly made PVs suitable for direct integration into construction in the world. Recently, building has been higher and higher. Tall buildings have many advantages for BIPV such as wide facade area and no shading effect by the surrounding buildings. However. BIPV has not been applied for tall building facade yet. Therefore, the purpose of the research is to develop suitable BIPV for tall buildings and to put these technologies to practical use. Therefore, the purpose of the study is to investigate unification of BIPV to curtain wall to apply BIPV on tall building through research into advanced application of overseas BIPV cases.

  • PDF

A Study on the Optimization of Color Module BIPV Architectural Design Using BIM - Based on the data of Seoul surveyed solar radiation - (BIM을 활용한 컬러모듈 BIPV 건축 설계 최적화 방안 연구 - 서울 지역 실증 일사량 데이터 중심으로 -)

  • Jeon, Hyun-Woo;Yoon, Hea-Kyung;Park, Suh-Jun
    • Journal of KIBIM
    • /
    • v.9 no.3
    • /
    • pp.19-29
    • /
    • 2019
  • Currently, BIPV (Building Integrated Photovoltaic) design technology lacks analysis function at the planning stage, and there is a lack of understanding and reliability of BIPV design method and system for building designers. To design and consider various building integrated solar design alternatives, the color of building integrated solar is often monotonous or does not match the design direction of the building. In this study, architectural designers can select various color modules in the planning and design process of the building and analyze the characteristics of color module solar cells and compare and analyze the actual solar radiation and predicted solar radiation in Republic ofKorea Seoul to reduce the confusion of design methods. By building a BIM design integrated system that can prove the quality of the building and analyze the shading analysis and power generation performance architecturally, it can improve the reliability of color module solar cell applicability that can express aesthetics in buildings and the predicted solar power generation capacity of each region. In the initial design stage, based on the empirical data of the BIPV system, it is possible to analyze the power generation performance for each installation angle and installation direction by analyzing the surrounding environment and the installation area, and accurately determine the appropriateness of the design accordingly.

Efficiency Improvement for Building Integrated Photovoltaic Applied to High-rise Building (고층 빌딩에 적용되는 빌딩통합형 태양광패널 효율성 개선방안)

  • Lee, Do-Hyun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2022
  • With the advent of cutting-edge technology, renewable energy is significantly considered as alternative resources to supply electric power. However, many barriers such as energy intermittency, high initial installation cost, and low-efficiency generation challenged building new infrastructure with clean energy. Efforts reducing greenhouse gas emissions and reliance on fossil fuels resulted in the decentralization of power generation like distributed energy resource (DER). This paper is to introduce and evaluate the feasibility of building-integrated photovoltaics (BIPV) in a high-rise building in Ulsan. To optimize BIPV, a variety of methods to minimize efficiency decrease and maximize electric power generation after installing BIPV on the building's facade are suggested. The variables causing power losses are analyzed. By utilizing System Advisor Model (SAM), actual power generated from solar panels is measured by Thin-film PV, Mono-crystalline PV, and Poly-crystalline PV.

A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories (대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구)

  • Seo, Won-Duck;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

Analyzing the Possibility of the Building Integrated Photovoltaic with DSC by the Case Studies (사례연구를 통한 DSC에 의한 BIPV 가능성 분석 연구)

  • Lee, Eung-Jik
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.54-63
    • /
    • 2017
  • The various colors and transparency of DSC and operability unrelated with directions greatly expand the use of BIPV, as a multi-functional composite of module. Therefore the possibility of DSC BIPV is examined by the case study and the analysis and then its applicability is examined. Most of the DSC BIPVs, which are found through a total of six case studies and analyzes in Korea and abroad, are mainly implemented with window glass and shading devices. This is related to the DSC transparency property. Improvements are due to the irritation of the eye due to the color of the red module. Therefore, it is important to take into account the color of the BIPV window depending on the use of the building and the room. Meanwhile, some colors of application model may stimulate eyes and such colors should be considered by use of buildings and rooms in the application of BIPV window. DSC BIPV has prospective diffusibility with the development of flexible module for the application of building surface.

Experimental Study on the Combined Effect of Power and Heat according to the Ventilation of Back Side in Roof Integrated PV System (주택 지붕일체형 PV시스템 후면환기에 따른 발전성능 변화 실험연구)

  • Yoon, Jong-Ho;Han, Kyu-Bok;An, Young-Sub
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.169-174
    • /
    • 2007
  • Building integrated photovoltaic(BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated. This study is to establish basic Information for designing effective BIPV by discovering relations between temperature and generation capability through experiment when the PV module is used as roof material for houses. To do so, we established 3kW full scale mock-up model with real size house and attached an PV array by cutting in half. This is to assess temperature influence depending on whether there is a ventilation on the rear side of PV module or not.

A Study on the Development of Roof Integrated PV Module (Focused on the Prefab Building System) (지붕재 일체형 태양전지 모듈의 개발에 따른 내구성 평가 (조립식 건축시스템을 중심으로))

  • Yi, So-Mi;Noh, Ji-Hee;Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.17-24
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. Architecture considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully refelected from the early stage of BIPV module design. Trial product of BIPV module are manufactured and sample construction details for demonstration building are purposed. Therefore, this paper intends to advanced its practical use by proposing how to get integrated PV system which can be applied to prefab building material, and how to apply it.

The Output Characteristics of 3kW BIPV System (3kW 건물일체형 태양광발전시스템의 출력특성)

  • Kim, Ji-Hoon;Kim, Pyouug-Ho;Lim, Yang-Su;Cho, Geum-Bae;Baek, Hyung-Lae;Oh, Geum-Gon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.471-474
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. But, there are many generation differences according to the exterior environmental facts(solar cell away, design and installation condition of interactive inverter system) Therefore, it is difficult to optimum design. Consequently in advance design system, we experiment 3kW BIPV(Building Integrated PV) generation. We concrete PV system efficient application of variable. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. This research is a basic study for application of building integrated photovoltaic system for builing.

  • PDF