• 제목/요약/키워드: Building Height

검색결과 1,084건 처리시간 0.026초

장애물 없는 생활환경(BF) 인증제도 계단 난간 높이 산정기준 개선안 (Improvement plan for the standard for calculating the height of the stair railing for Barrier Free (BF) certification system)

  • 이상수;방홍순;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.218-219
    • /
    • 2022
  • Among the Barrier Free (BF) certification evaluation items for public facilities, at which position the standard for the effective height of the stair railing handle should be calculated is not clearly determined. Because of this, not only the evaluation standards of the certification authority and the evaluation committee are different, but disputes are occurring between the ordering organization, the design company, and the construction company. Therefore, the stair railing installation standard laws for public facilities were analyzed and through a case study of institutions that obtained the BF certification, problems were analyzed. The results of problem analysis reveal the following. 1) The standards of the Ministry of Health and Welfare and the Ministry of Land, Infrastructure, and Transport were different. 2) The effective height calculation standard was ambiguous, and disputes occurred frequently. To solve this problem, we proposed improvement plans for calculating the height of the stair railing that can comply with laws while ensuring safety.

  • PDF

비정형 초고층 건물의 바람에 의한 편심응답 특성 (Characteristics of wind-Induced Coupled Motion of Tapered and Setback Tall Buildings)

  • 김용철;칸다 준;타무라 유키오
    • 한국공간구조학회논문집
    • /
    • 제13권1호
    • /
    • pp.79-86
    • /
    • 2013
  • For most of recent tall buildings, one characteristic is that their building shapes vary with height such as taper and setback, and this implies that the distribution of their structural components may also vary with height. Because of these structural variations, although the sectional shapes of these buildings are symmetric, it is difficult to say whether or not they are structurally symmetric. The acceleration responses of structurally asymmetric tall buildings are larger than those of non-eccentric buildings, thus raising the possibility of problems during strong winds and typhoons. This paper describes wind tunnel tests carried out using building models with height variations and acceleration response analyses, and discusses the resulting response characteristics. For tapered and setback buildings, although the across-wind accelerations are larger than those of a square building, the total root-mean-square accelerations remain small because of smaller along-wind and torsional rms accelerations. And it was found that the effects of statistical couplings between along-wind force and other two forces are negligible.

Towards guidelines for design of loose-laid roof pavers for wind uplift

  • Mooneghi, Maryam Asghari;Irwin, Peter;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • 제22권2호
    • /
    • pp.133-160
    • /
    • 2016
  • Hurricanes are among the most costly natural hazards to impact buildings in coastal regions. Building roofs are designed using the wind load provisions of building codes and standards and, in the case of large buildings, wind tunnel tests. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. The objective of this paper is to develop simple guidance in code format for design of loose-laid roof pavers. Large-scale experiments were performed to investigate the wind loading on concrete roof pavers on the flat roof of a low-rise building in Wall of Wind, a large-scale hurricane testing facility at Florida International University. They included wind blow-off tests and pressure measurements on the top and bottom surfaces of pavers. Based on the experimental results simplified guidelines are developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as American Society of Civil Engineering (ASCE) 7-10 standard's pressure coefficients for components and cladding. The effects of the pavers' edge-gap to spacer height ratio and parapet height to building height ratio are included in the guidelines as adjustment factors.

판상형 공동주택의 동 배치 및 종횡비에 따른 풍압계수 특성에 관한 연구 (A Study on the Wind Pressure Coefficients of Flat-type Apartment Complexes Considering Building Layout and Aspect Ratio)

  • 윤성훈
    • 한국융합학회논문지
    • /
    • 제12권9호
    • /
    • pp.153-159
    • /
    • 2021
  • 건축물의 환기성능 평가를 위한 모델링 과정에서 핵심 경계조건으로 활용되는 풍압계수는 통상 저층형 단일 건물에 대해서만 자료화되어 있어, 공동주택 단지와 같은 고층형 집합주택의 모델링 시에는 적용할 수 없다. 이에 본 연구에서는 CFD(Computational Fluid Dynamics)해석을 통해 건물의 배치 및 종횡비가 다른 판상형 공동주택에 대하여 풍향각에 따른 풍압계수의 특성을 분석하고 유형화함으로써 환기 모델링 시 참고할 수 있는 기초자료를 제시하였다. 풍향각 0도의 경우 가장 풍상측에 위치한 건물의 정면에서는 좌우가 반전된 S자 형태의 풍압계수 분포가 나타났으며, 최하층, 최상층 및 2개의 변곡점에 해당하는 풍압계수는 건물의 높이와 관계없이 비교적 근사한 값을 보였다. 저층부의 변곡점은 약 11m 높이에 형성되었으며, 고층부 변곡점의 높이는 건물의 높이에 비례하는 추세식을 통해 산출가능함을 확인하였다. 또한 풍향각 45도 조건을 제외하면 대부분의 조건에서 풍압계수의 평균값을 적용 가능함을 확인하였다.

EXTRACTING OUTLINE AND ESTIMATING HEIGHT OF LAND FEATURES USING LIDAR DATA

  • Lee, Woo-Kyun;Song, Chul-Chul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.181-183
    • /
    • 2006
  • Digital topographic map in Korea contains layers of spatial and attribute data for 8 land features such as railroads, watercourses, roads, buildings and etc. Some of the layers such as building and forest don't include any information about height, which can be just prepared by interpretation of remote sensed data or field survey. LiDAR(Light Detection And Ranging) data using active pulse and digital camera provides data about height and form of land features. LiDAR data can be used not only to extract the outline of land features but also to estimate the height. This study presents technical availability for extraction and estimation of land feature's outline and height using LiDAR data which composes of natural and artificial land features, and digital aerial photograph which was taken simultaneously with the LiDAR. The estimated location, outline and height of land features were compared with the field survey data, and we could find that LiDAR data and digital aerial photograph can be a useful source for estimating the height of land features as well as extracting the outline.

  • PDF

ANI Girder(앵글 및 래티스 철근으로 구성된 강조립보)와 HCS(Hollow Core Slab)를 활용한 지하주차장 (Underground Parking Lot by ANI Girder(ANgle Integrated Girder) and HCS)

  • 최익준;전병갑;염경수;최성모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2016
  • Through the story height reducing method, cost saving can be implemented in many aspects. Recently, as one of PC floor system, HCS(Hollow Core Slab) has been applied in many project, and it is proved that it is excellent in productivity, economic efficiency, and workability as well. We developed a new composite beam(ANI Girder) which can be associated with HCS and reinforced with a truss-shape rebar and angle. As a result of actual application on underground parking building with HCS, it is confirmed that this system is effective in workability and story height reducing.

  • PDF

고차모드 효과를 고려한 층 지진하중 분배 (the height-wise distribution of lateral seismic forces considering the contribution of the higher modes)

  • 황준호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.273-280
    • /
    • 1999
  • The base shear and the veritcal distribution of shears along the height of a building are two fundamental measures that define the design seismic load. But the method specified in Korean building code does not give an appropriate distribution for buildings of tall or longer period because it roughly account for the contributions of the higher modes. several methods to give a better distribution of seismic forces have been proposed. But they have not been introduced into the seismic codes yet probably because they cannot solve all the above-mentioned problems. This paper deals with the distribution of lateral seismic forces along the height of a building to account for the contribution of the higher modes. After reviewing some existing distributions in seismic codes and literatures moment-resisting frames with various stories were studied by modal analysis for a wide range of fundamental period and the stiffness ratio of the buiding. As a result of the analysis a new expression for the distribution of seismic forces is proposed and compared with those of some codes and dynamic analysis.

  • PDF

석고보드 벽체의 시공높이에 따른 수평하중저항성 및 내충격성 변동 특성 (Variation Characteristics of Stiffness and Impact Resistance under Conastruction Height of Gypsum Board Wall)

  • 송정현;김기준;안홍진;신윤호;지석원;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.184-185
    • /
    • 2014
  • The purpose of this study is to experimentally evaluate the variation characteristics of stiffness and impact resistance under the construction height of gypsum board wall at the actual construction site. The method suggested in previous study was applied on the test method of horizontal load resistance and impact resistance. As a result of horizontal load resistance test, when the wall height is 2,400 mm, the maximum displacement is 13.6 mm and residual deformation is 0.5 mm, and when the wall height is 3,000 mm, the maximum displacement is 31.3 mm and the residual displacement is 6.8 mm. As a result of impact resistance test, the residual deformation of each specimen at 20 cm of fall height were 1.02 mm and 0.08 mm, respectively, the residual deformation at 40 cm of fall height were 1.58 mm and 0.35 mm, respectively, and the residual deformation at 60 cm of fall height were 2.23 mm and 2.48 mm, respectively.

  • PDF

표준시험동 바닥충격음 측정위치에 대한 고찰 (Investigation of receiving position in the measurement method for floor impact sound in a testing building)

  • 이신영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

도시가로의 형태요소와 대기질과의 관계 연구 (Analyzing the Relationship between the Spatial Configuration of Urban Streets and Air Quality)

  • 주정현;오규식;정연우
    • 한국환경복원기술학회지
    • /
    • 제12권2호
    • /
    • pp.73-82
    • /
    • 2009
  • The traffic volume of Seoul is extremely high in comparison to other major cities in Korea, and the result has been harmful physical and mental exposure to pollution by Seoulites on a regular basis. The street air pollution is more important than the others, because the air pollution generated by street traffic directly impacts the health of nearby pedestrians. This problem requires urgent attention and resolution. Among the factors creating the air pollution originating from the street, is the configuration of streets, which have emerged as the most significant because it is related to air and pollutant dispersion. Therefore, this study was conducted under the assumption that street form affects the air quality. Study sites were classified by street characteristics, and air quality was analyzed in each class. Then the OSPM (Operational Street Pollution Model) was employed to simulate the relationship between street configuration and air quality of streets within the old city center and new city center in Seoul. After that this study analyzed the correlation between air pollution and the spatial configuration of urban streets (ex. street width, building height, building density, etc.) to determine their contributions to air pollution. The outcome of this study is as follows : First, the result that was derived from the correlation analysis between street configuration and air quality hewed that the air pollution of the street is influenced by the average height of building, width of the roads as well as traffic volume. On the roadside, the concentration level of $NO_2$ is mainly affected by the average height of building and the deviation of building height along the street and CO is affected by street width. The outcome of this study can be used as a basis for more sound urban design policies, and the promotion of desirable street environments for pedestrians.