• Title/Summary/Keyword: Building Facility

Search Result 1,251, Processing Time 0.026 seconds

Structure and Change Pattern of Gijang Mountain Fortress and its Receiving Reservoir (기장산성 집수지의 구조와 변화양상)

  • Hwang, Dae-Il;Jung, Dae-Bong;Park, Jun-Hyun
    • Journal of architectural history
    • /
    • v.22 no.4
    • /
    • pp.35-44
    • /
    • 2013
  • This paper looked into the structure of and changes in the building process of Gijang mountain fortress and its receiving reservoir by analyzing data from an excavation investigation. The structure of the receiving reservoir may be classified into a flat form, stone sheath, floor facility, wall facility, and entry and exit facility. The flat form of the Gijang mountain fortress and receiving reservoir is round. Concerning the sectional form, the wall was obliquely excavated in the trapezoid. As a stone sheath building method, it was built by undertaking a range work of oblong stone materials in a clockwise direction on a stamped soil floor. Then, it was treated with stamping using double layers of gray clay and yellowish brown clay on the floor and the wall. Also, in a space between the stamped layers on the floor, herbal plants and a straw mat were laid for waterproofing as well as to prevent sinking. As an entry and exit facility, two facilities were confirmed symmetrically in the southeast and in the northwest. It is believed that they were built additionally during rebuilding after the initial construction. The building process was revealed to have been carried out in 8 stages. Given the structure and excavated remains, the building period is estimated to be the early to mid 7th century for the initial building, the later 9th to 11th centuries for the primary rebuilding, and the later 16th to early 17th centuries for the secondary rebuilding.

A Comparative Analysis on the School Building Area per Student for the Revision of School Facility Standard (학교시설 면적기준 개정을 위한 학생 1인당 시설면적 비교 분석)

  • Cho, Jin-il;Choi, Hyeong-ju;Park, Sung-chu
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.14 no.2
    • /
    • pp.1-11
    • /
    • 2015
  • The existing school facility recommendations enacted in 1997 has not been suitable for current school curriculum. The objective of the paper is to present the school building area reflecting the current education policies and curriculum. This paper firstly reviewed previous school facility recommendations through literature review. Secondly, the statistical approach was carried out for analyzing the present situation of school building area by using statistical database of Korean Educational Development Institute. The paper did the field investigation and questionnaire. And, the final step proposed the school building area standards(minimum, optimum, maximum) by space program using Nelson model. The contents of analyzing space organization are 'entry and placement, outdoor space', 'space program' and 'phase structure and organization of unit space'.

A Study on the Development of the Assessment Category and Items for University Facility Management (대학시설관리를 위한 평가분류체계 및 평가항목 개발 연구)

  • Ryu, Soo-Hoon;Lee, Hwa-Ryoung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.6
    • /
    • pp.22-29
    • /
    • 2008
  • For university facility and space management to be public, and to increase the administrational efficiency, this research suggests an efficient as well as an objective evaluation system/index to allow national and university finances to contribute towards higher education. According to the result of this study, evaluation system for university facility can be widely divided into two categories; quality and space management. First, quality management is subdivided into three groups in order for quantitative management, school site and building area, secured building, and financial affairs and expense management. In order for an effective and appropriate space management, the second category of space management proposes seven subdivisions. Based on these subdivisions, quality management on university facility contains 10 evaluation items with marking system which allows perfect score of 50 points. The space management category contains 19 evaluation items and the marking system allows perfect score of 100 points. Therefore, this study developed total of 29 evaluation items for university facility management with marking system that allows perfect score of 150 points. The suggested evaluation system and items will be used as a valuable foundation for efficient and objective university facility management.

Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings (다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구)

  • 김윤신;이은규;엽무종;김기영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.3-5
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991-February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001-June 2001 in Seoul. The results were as follows : 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. 2. The average of staphylcocci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were Underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites

  • PDF

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

The Plan on the Seismic Design of Electrical Facility Installed in the Building (건축물에 시설되는 수변전설비 내진설계 방안)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong;Cho, Sung-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Recently life and properties damage at Japan and China by generating earthquake. So earthquake generation trend and damage in the earthquake risk, and these are a growing interest in domestic. This paper analyzes domestic site and problems of earthquake measures for electrical facility at transformer vault which supply the power the emergence situation at generating earthquake. Also we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility, reliability inspection plan for seismic design and construction of electrical facility.

Development of Common Data Standard for Airports Facilities based on Building Information Modeling (BIM) (공항시설물에 대한 BIM 기반의 공통 데이터 표준 구축 방안)

  • Jung, Euisoo;Kim, Kee-Woong;Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.29 no.3
    • /
    • pp.100-110
    • /
    • 2021
  • Building Information Modeling(BIM) technology continues to develop and is now being applied to infrastructure facilities. As smart technology based on BIM is applied to the construction industry, the construction of the same data in a common environment is considered to be a very important step in various applications. This study was conducted on methods to establish an open BIM-based airport facility information common data environment. Therefore, this study develops the element technology to establish a common data environment for the integrated management of airport facility information, and aims to standardize data in the common data environment among various technologies and applications. In order to achieve the aim, in this study, the required technologies were derived by examining the common data environment and examining the civil engineering facility field and the case of integrated airport facility management. Through this, standards and development for information standard framework, information requirement level, BIM guidebook, and BIM library were developed in connection with national and higher standards. Through these standards, it is expected that the integrated management of various airport facilities will be efficiently carried out through a standard data platform in the future.

Considerations for Developing a SLAM System for Real-time Remote Scanning of Building Facilities (건축물 실시간 원격 스캔을 위한 SLAM 시스템 개발 시 고려사항)

  • Kang, Tae-Wook
    • Journal of KIBIM
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In managing building facilities, spatial information is the basic data for decision making. However, the method of acquiring spatial information is not easy. In many cases, the site and drawings are often different due to changes in facilities and time after construction. In this case, the site data should be scanned to obtain spatial information. The scan data actually contains spatial information, which is a great help in making space related decisions. However, to obtain scan data, an expensive LiDAR (Light Detection and Ranging) device must be purchased, and special software for processing data obtained from the device must be available.Recently, SLAM (Simultaneous localization and mapping), an advanced map generation technology, has been spreading in the field of robotics. Using SLAM, 3D spatial information can be obtained quickly in real time without a separate matching process. This study develops and tests whether SLAM technology can be used to obtain spatial information for facility management. This draws considerations for developing a SLAM device for real-time remote scanning for facility management. However, this study focuses on the system development method that acquires spatial information necessary for facility management through SLAM technology. To this end, we develop a prototype, analyze the pros and cons, and then suggest considerations for developing a SLAM system.

The Improvement of Delivery System for International Sports Complex Facility (국제종합경기 시설공사 발주방법의 개선 방안)

  • Choi Yong-Ho;Lee Soo-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.107-112
    • /
    • 2005
  • Renovation of existing sports facilities or construction of temporary ones for international complex games requires a wide variety of hundreds of sub construction projects to be awarded at the same time but there are few precedents required regarding the study of tendering process required in such cases. As award of construction contracts to build sports facilities for various international complex games is a critical determinant of fate of international complex games in the initial phase, it is very critical that adequate construction tendering process bedetermined. This research is aimed to study tendering cases for renovation or construction of critical international sports facilities to enhance efficiency of facility construction and define most reasonable tendering approach to satisfy schedule constraints often associated with international complex games and contribute to improvement of international competitiveness of their host cities and propose a direction for further development. This study also provides inputs to subsequent sports events of comparable scale to minimize trial and error.

  • PDF

STUDY ON X-RAYS AND NEUTRONS LEAKED FROM A 45 MeV ELECTRON LINAC FACILITY

  • Sawamura, Sadashi;Kitaichi, Masatoshi;Nojiri, Ichiro;Yamada, Takuma;Kaneko, Junichi;Sawamura, Teruko
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.133-137
    • /
    • 2001
  • Spatial and time distributions of x-rays and neutrons from Hokkaido University 45 MeV electron linac facility were measured and compared with the calculation. In the calculation, x-rays in a Pb-target were evaluated using the EGS-code. The x-rays and the neutrons from the target to the facility building boundary and skyshine process outside the facility building were simulated with the EGS and the MCNP respectively.

  • PDF