• Title/Summary/Keyword: Brittle

Search Result 1,770, Processing Time 0.026 seconds

Quantitative assessment of depth and extent of notch brittle failure in deep tunneling using inferential statistical analysis

  • Lee, Kang-Hyun;Lee, In-Mo;Shin, Young-Jin
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.201-206
    • /
    • 2020
  • A stress-induced brittle failure in deep tunneling generates spalling and slabbing, eventually causing a v-shaped notch formation. An empirical relationship for the depth of the notch to the maximum tangential stress assuming an equivalent circular cross-section was proposed (Martin et al. 1999). While this empirical approach has been well recognized in the industry and used as a design guideline in many projects, its applicability to a non-circular opening is worth revisiting due to the use of equivalent circular profile. Moreover, even though the extent of the notch also contributes to notch failure, it has not been estimated to date. When the estimate of both the depth and the extent of notch are combined, a practical and economically justifiable support design can be achieved. In this study, a new methodology to assess the depth as well as the extent of notch failure is developed. Field data and numerical simulations using the Cohesion Weakening Frictional Strengthening (CWFS) model were collected and correlated with the three most commonly accepted failure criteria (σ13, Dismaxc, σdevcm). For the numerical analyses, the D-shaped tunnel was used since most civil tunnels are built to this profile. Inferential statistical analysis is applied to predict the failure range with a 95% confidence level. Considering its accuracy and simplicity, the new correlation can be used as an enhanced version of failure assessment.

Effect of the Elasticity Modulus of the Jig Material on the Blade Edge Shape in the Grinding Process of Sapphire Medical Knife - Part 2 Verification of the Chipping Phenomenon and Elastic Modulus of the Jig Material (사파이어 의료용 나이프의 연삭가공에서 지그의 탄성계수가 날 부 형상에 미치는 영향 : 제2보 탄성계수와 치핑 현상의 검증)

  • Shin, Gun-Hwi;Kang, Byung-Ook;Kwak, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.63-68
    • /
    • 2017
  • This study determines the selection of an appropriate jig material for the blade edge of the medical sapphire knife. The physical properties of the jig material affects the edge shape and chipping phenomenon in machining of the medical sapphire knife. If a grinding wheel is used, brittle workpieces such as sapphire are easily damaged by the propagation of cracks because the grinding force significantly increases. It is important to constantly maintain the grinding force in the grinding process of the brittle materials. The grinding force can be kept constantly by inducing the elastic deformation of the Jig material because the elastic deformation of brittle work-piece is negligibly low. The chipping phenomenon may be reduced by selecting the proper Jig material. Aluminum, copper, stainless steels and carbon steel were used as Jig materials. The experiment was conducted using a cast iron grinding wheel, which was installed on a conventional grinding machine with the ELID grinding system. The thickness and width of the chipping area were measured using an optical microscope and FE-SEM to analyze the shape of the blade edge. According to the experiment result, the chipping phenomenon decreased, and the sharp edge was formed when the jig materials with low elastic modulus were used.

The Estimation of Activation Energy for Prism Plane SliP {1120} <1100> Dislocation Velocity in Sapphire Single Crystals using Brittle-to-ductile Transition Model (취성-연성 전이 model을 이용한 사파이어 단결정의 prism plane slip {1120} <1100> 전위속도에 대한 활성화에너지 계산)

  • Yun, Seog-Young;Lee, Jong-Young
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.508-511
    • /
    • 2001
  • Experimental studies of the brittle-ductile transition (BDT) for pre-cracked sapphire single crystals were carried out. The BDT temperature in sapphire single crystals were $1000\pm$$25^{\circ}C$ and 1100$\pm$$25^{\circ}C$ at constant strain rate 3.3$\times$$10^{-5}$/sec and 3.3$\times$$10^{-6}$/sec, respectively. With aid of the BDT model, the activation energy for prism plane slip {1120} <1100> dislocation velocity was in the range of 4.6$\pm$2.3eV This activation energy for dislocation velocity with BDT model was compatible with the result of the dislocation velocity (3.8eV) using the etch-pit techniques.

  • PDF

A Study on the Safety of Lifting Cable for Construction of Coastal Structures (항만건설을 위한 케이슨 들고리의 안전성에 관한 연구)

  • Kwak, Kae Hwan;Jang, Ki Woong;Kim, Jong Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.85-99
    • /
    • 1998
  • This paper describes an experimental study to examine collapse causes of the lifting cable due to brittle failure of an fitting anchor under the lifting works. Also, in this study an collapse mechanism that was obtained from stress analysis was compared with an actual collapse procedure. Fractographical analysis as well as chemical component test, tension test and Charpy V-Notch impact test for the fractured steel members were carried out. And then, its results were compared with that of normal steel members. Circumferential surface flaws were developed at internal facets of the fitting anchor before tensile stress occurred. Hence, a higher stress than nominal stress was occurred at flaws by stress concentration at the crack tip. Also, stress intensity factor of members increased by crack size of the potential flaws. Because the stress intensity factor at the crack tip was greater than critical values(fracture toughness), brittle fracture occurred under the lifting works. It is judged that the main collapse of the lifting cable is due to brittle fracture of the fitting anchor.

  • PDF

Experimental Study of Hybrid Super Coating (HSC) and Cast Reinforcement for Masonry Wall (하이브리드 슈퍼코팅(HSC)과 유리섬유를 통한 조적조 내진보강 연구)

  • Lee, Ga Yoon;Moon, A hea;Lee, Seung Jun;Kim, Jae Hyun;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.213-221
    • /
    • 2021
  • Many Korean domestic masonry structures constructed since 1970 have been found to be vulnerable to earthquakes because they lack efficient lateral force resistance. Many studies have shown that the brick and mortar suddenly experience brittle fracture and out-of-plane collapse when they reach the inelastic range. This study evaluated the seismic retrofitting of non-reinforced masonry with Hybrid Super Coating (HSC) and Cast, manufactured using glass fiber. Four types of specimen original specimen (BR-OR), one layered HSC (BR-HS-O), two-layered HSC (BR-HS-B), one layered HSC, and Cast (BR-CT-HS-O) were constructed and analyzed using compression, flexural tensile, diagonal compression, and triplet tests. The specimen responses were presented and discussed in load-displacement curves, maximum strength, and crack propagation. The compressive strength of the retrofit specimens slightly increased, while the flexural tensile strength of the retrofit specimens increased significantly. In addition, the HSC and Cast also produced a considerable increase in the ductile response of specimens before failure. Diagonal compression test results showed that HSC delayed brittle cracks between the mortar and bricks and resulted in larger displacement before failure than the original brick. The triplet test results confirmed that the bonding strength of the retrofit specimens also increased. The application of HSC and Cast was found to restrain the occurrence of brittle failure effectively and delayed the collapse of masonry wall structures.

Effect of Shearing Speed and UBMs on High Speed Shear Properties of Sn3.0Ag0.5Cu Solder Ball (Sn3.0Ag0.5Cu 솔더 볼의 고속 전단특성에 미치는전단속도 및 UBM층의 영향)

  • Jung, Do-Hyun;Lee, Wang-Gu;Jung, Jae Pil
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.8
    • /
    • pp.635-641
    • /
    • 2011
  • The effect of high shear speed on shear force, shear energy and fracture surface was investigated for the solder joint of a $Sn-_{3.0}Ag-_{0.5}Cu$ ball. For both ENIG and OSP pads, the shear force increased with an increase in shearing speed to 0.3 m/s. However, for an ENEPIG pad, the shear force increased with an increase in shear speed to 0.6 m/s and kept almost constant afterward. The shear energy decreased with an increase in shearing speed for ENIG and OSP pads. For the ENEPIG pad, however, the shear energy almost remained constant in a shearing speed range 0.3-3.0 m/s. The fracture mode analysis revealed that the amount of brittle fracture for the ENIG and the OSP pads increased with shearing speed, and a complete brittle fracture appeared at 1.0 m/s for ENIG and 2.0 m/s for OSP. However, the ENEPIG pad showed only a ductile fracture until 0.25 m/s, and a full brittle fracture didn't occur up to 3.0 m/s. The fracture mode matched well with the shear energy. The results from the high speed shear test of SAC305 were similar to those of SAC105.

Evaluation of Moment Transfer Efficiency According to the Connection Length of the Column Flange and the Beam Web of the H-beam Column Connection (H형강 보-기둥 접합부의 보 웨브 단부접합길이에 따른 모멘트전달효율 평가)

  • Hong, Young-Ju;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.193-203
    • /
    • 2022
  • In this study, in order to compare the seismic performance of steel structure beam-column connection details and non-scallop connection details mainly used in Korea, a full-scale static cyclic loading test and FEM analysis were conducted through the same modeling as the experiment. For quantitative numerical comparison, the strain concentration ratio and moment transfer efficiency used in previous studies were cited. As the welding area of the beam web decreased, the deformation rate of the beam flange increased, and the plastic deformation capacity according to the rotation angle decreased or brittle fracture occurred. Comparing the analysis results with the experimental results, the possibility of brittle fracture tended to increase when the web welding ratio for the total cross-sectional area of H-shaped fell below 60%.

A Study on the Charpy Impact Performance of Structural Steel Considering the Leakage of Cryogenic Liquefied Gas (극저온 액화가스 누출에 의한 선체 구조용 강재의 샤르피 충격성능에 관한 연구)

  • Dong Hyuk Kang;Jeong-Hyeon Kim;Seul-Kee Kim;Tae-Wook Kim;Doo-Hwan Park;Ki-Beom Park;Jae-Myung Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.333-340
    • /
    • 2023
  • Environmental regulations are being strengthened worldwide to solve global warming. For this reason, interest in eco-friendly gas fuels such as LNG and hydrogen is continuously increasing. However, when adopting eco-friendly gas fuel, liquefying at a cryogenic temperature is essential to ensure economic feasibility in storage and transportation. Although austenitic stainless steel is typically applied to store cryogenic liquefied gas, structural steel can experience sudden heat shrinkage in the case of leakage in the loading and unloading process of LNG. In severe cases, the phase of the steel may change, so care is required. This study conducted Charpy impact tests on steel material in nine different temperature ranges, from room to cryogenic temperatures, to analyze the effects of cryogenic liquefied gas leaks. As a result of the study, it was not easy to find variations in ductile to brittle transition temperature (DBTT) due to the leakage of cryogenic liquefied gas. Still, the overall impact toughness tended to decrease, and these results were verified through fracture surface analysis. In summary, brittle fracture of the steel plate may occur when a secondary load is applied to steel for hull structural use exposed to a cryogenic environment of -40 ℃ or lower. Therefore, it needs to be considered in the ship design and operating conditions.

Brittle rock property and damage index assessment for predicting brittle failure in underground opening (지하공동의 취성파괴 예측을 위한 암석물성 및 손상지수 평가)

  • Lee, Kang-Hyun;Bang, Joon-Ho;Kim, Jin-Ha;Kim, Sang-Ho;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.327-351
    • /
    • 2009
  • Laboratory tests are performed in this paper to investigate the brittle failure characteristics of over-stressed rocks taken in deep depth. Also, numerical simulation performed using that the so-called CWFS(Cohesion Weakening Frictional Strengthening) model is known to predict brittle failure phenomenon reasonably well. The most typical rock types of Korean peninsula - granite and gneiss - were used for testing. Results of uniaxial compression tests showed that the crack initiation stress was about 41 % to 42% of the uniaxial compressive strength regardless of rock types, where as, the crack damage stress of granite was about 75%, and that of gneiss was about 97%. Through the damage-controlled test, strength parameters of each rock were obtained as a function of damage degree. After the peak, the crack damage stress and the maximum stress were decreased, The cohesion was decreased and the friction angle was increased with increase of rock damage. Before reaching the peak, the elastic modulus was slightly increased, while decreased after the peak. Poisson's ratio was increased as the damage of rock proceeds. Comparison of uniaxial compression tests and damage-controlled tests shows the crack initiation stress estimated from the damage-controlled test fluctuated within the range of crack initiation stress obtained from the uniaxial compression test; the crack damage stress was less than that estimated from the uniaxial compression test. In order to predict the critical depth that brittle failure occurs, numerical simulations using the CWFS model were performed for an example site. Material parameters obtained from the laboratory tests mentioned above were used for CWFS simulation. Comparison between the critical depth predicted from the numerical simulation using the CWFS model and that predicted by using the damage index proposed by Martin et al.(l999), showed that critical depth cannot be reasonably predicted by the currently used damage index except for circular tunnels. A modified damage index was proposed by the author which takes the shape of tunnels other than circular into account.

Demand Strength Spectrums of Low-Rise Reinforced Concrete Buildings Consisted of Extremely Brittle, Shear and Flexural Failure Systems (극취성·전단·휨파괴형 수평저항시스템으로 구성된 저층 철근콘크리트 건물의 요구 내력 스펙트럼)

  • Lee, Kang-Seok;Kim, Jeong-Hee;Oh, Jae-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.529-537
    • /
    • 2007
  • The purpose of this study is to discuss how strength and ductility of each system in low-rise reinforced concrete buildings composed of extremely brittle, shear and flexural failure lateral-load resisting systems have influence on seismic capacities of the overall system, which is based on nonlinear seismic response analyses of single-degree-of-freedom structural systems. In order to simulate the triple lateral-load resisting system, structures are idealized as a parallel combination of two modified origin-oriented hysteretic models and a degrading trilinear hysteretic model that fail primarily in extremely brittle, shear and flexure, respectively. Stiffness properties of three models are varied in terms of story shear coefficients, and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of demand strengths of the triple system for various levels of ductility factors are finally derived for practical purposes. The result indicates that demand strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete buildings having the triple lateral-load resisting system.