• Title/Summary/Keyword: Brightness Temperature

Search Result 450, Processing Time 0.027 seconds

Effects of some factors on the thermal-dissipation characteristics of high-power LED packages

  • Ji, Peng Fei;Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Decreasing the thermal resistance is the critical issue for high-brightness light-emitting diodes. In this paper, the effects of some design factors, such as chip size (24 and 35 mil), substrate material (AlN and high-temperature co-fired ceramic), and die-attach material (Ag epoxy and PbSn solder), on the thermal-dissipation characteristics were investigated. Using the thermal transient method, the temperature sensitivity parameter, $R_{th}$ (thermal resistance), and junction temperature were estimated. The 35-mil chip showed better thermal dissipation, leading to lower thermal resistance and lower junction temperature, owing to its smaller heat source density compared with that of the 24-mil chip. By adopting an AlN substrate and a PbSn solder, which have higher thermal conductivity, the thermal resistance of the 24-mil chip can be decreased and can be made the same as that of the 35-mil chip.

A Study on the Preference of Fluorescent Lamp and White LEDs by the Comparison of Color Temperature in a Office Space (사무공간에서 형광램프 조명기구와 백색 LED 조명기구의 색온도 비교를 통한 선호도에 관한 연구)

  • Jung, Yeon-Hong;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.3-6
    • /
    • 2008
  • The purpose of this study is to investigate the luminous environment of fluorescent lamp and LED lamp in a office space for various color temperature by subject response test. For this, three different color temperatures were tested for the same illuminance level. Based on such test results for various color temperatures of fluorescent lamp and white LEDs, this study is to analyze the preferences of color temperature and light source, and perceptional brightness of each light source and color temperature. Then, this study is to derive the guidelines for the performance of color temperature which are suitable on the purpose and the mood of a office space.

  • PDF

The Relationship between GMS-5 IR1 Brightness Temperature and AWS Rainfall: A heavy rain event over the mid-western part of Korea for August 5-6, 1998 (GMS-5 IR1 밝기온도와 AWS 강우량의 관계성: 1998년 8월 중서부지역 집중호우 사례)

  • 권태영
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.1
    • /
    • pp.15-31
    • /
    • 2001
  • The relationship between GMS-5 IR1 brightness temperature (CTT:cloud top temperature) and AWS (automatic weather station) rainfall is investigated on a heavy rain event over the mid-western part of Korea for August 5-6, 1998. It is found that a temporal variability of the heavy rain can be described in detail y the time series of rain area and rain rates over the study area that are calculated from AWS accumulated rainfalls for 15 minutes. A time period of 0030-0430 LST 6 August 1998 is chosen in the time series as a heavy rain period which has relatively small rain area (20~25%) and very strong rain rates(6~9 mm/15 min.) with a good time continuity. In the heavy rain period, CTT of a point and AWS 15-minute rainfall beneath that point are compared. From the comparison, AWS rainfalls are shown to be not closely correlated with CTT. In the range of CTT lower than -5$0^{\circ}C$ where most AWS with rain are distributed, the probability of rain is at most about 30%. However, when the satellite images are shifted by 2~3 pixels southward and 3 pixels westward for the geometric correction of images, AWS rainfalls are shown to be statistically correlated with CTT (correlation coefficient:-0.46). Most AWS with rain are distributed in the much lower CTT range(lower than -58$^{\circ}C$), but there is still not much change in the rain probability. Even though a temporal change of CTT is taken into account, the rain probability amount to at most 50~55% in the same range.

Fabrication of the Wafer Level Packaged LED Integrated Temperature Sensor and Configuration of The Compensation System for The LED's Optical Properties (온도센서가 집적된 WLP LED의 제작과 이를 통한 광 특성 보상 시스템의 구현)

  • Kang, In-Ku;Kim, Jin-Kwan;Lee, Hee-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.1-9
    • /
    • 2012
  • In this paper, resistance temperature detector (RTD) integrated into the LED package is proposed in order to solve the temperature dependence of LED's optical properties. To measure the package temperature in real time, the RTD type temperature sensor having excellent accuracy and linearity between temperature change and resistance change was adopted. A stable metallic film is required for long term reliability and stability of the RTD type temperature sensor. Therefore, deposition and annealing condition for the film were determined. Based on the determined condition, the RTD type temperature sensor with the sensitivity of about $1.560{\Omega}/^{\circ}C$ was fabricated inside the LED package. In order to configurate the LED package system keeping the constant brightness regardless of the temperature, additional conversion circuit and control circuit boards were fabricated and added to the fabricated LED package. The proposed system was designed to compensate the light intensity caused by temperature change using the variable duty rate of driving current. As a result, the duty rate of PWM signal which is the output signal of the configurated system was changed with the temperature change, and the duty rate was similarly varied with the target duty rate. Consequently, it was focused the fabricated RTD can be used for compensating the optical properties of LED and the LED package which exhibits constant brightness regardless of the temperature change.

Design of X-ray Target for a CNT-based High-brightness Microfocus X-ray Tube (탄소나노튜브를 이용한 고휘도 마이크로빔 X-선원 발생부 설계)

  • Ihsan Aamir;Kim Seon Kyu;Heo Seong Hwan;Cho Sung Oh
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.103-109
    • /
    • 2006
  • A target for a high-brightness microfocus x-ray tube, which is based on carbon nanotubes (CNT) as electron source, is designed. The x-ray tube has the following specifications: brightness of $1\times10^{11}phs/s.mm^2. mrad^2$, spot size $\~5{\mu}m$, and average x-ray energy of $20\~40 keV$. In order to meet the specifications, the design parameters of the target, such as configuration, material, thickness of the target as well as the required beam current, were optimized using computer code MCNPX. The design parameters were determined from the calculation of both x-ray spectrum and intensity distribution for a transmission type configuration. For the thin transmission type target to withstand vacuum pressure and localized thermal loading, the structural stability and temperature distribution were also considered. The material of the target was selected as molybdenum(Mo) and the optimized thickness was $7.2{\mu}m$ to be backed by $150{\mu}m$ beryllium (Be). In addition, the calculations revealed that the maximum temperature of the transmission target can be maintained within the limits of stable operation.

Study on the Effect of Emissivity for Estimation of the Surface Temperature from Drone-based Thermal Images (드론 열화상 화소값의 타겟 온도변환을 위한 방사율 영향 분석)

  • Jo, Hyeon Jeong;Lee, Jae Wang;Jung, Na Young;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • Recently interests on the application of thermal cameras have increased with the advance of image analysis technology. Aside from a simple image acquisition, applications such as digital twin and thermal image management systems have gained popularity. To this end, we studied the effect of emissivity on the DN (Digital Number) value in the process of derivation of a relational expression for converting DN to an actual surface temperature. The DN value is a number representing the spectral band value of the thermal image, and is an important element constituting the thermal image data. However, the DN value is not a temperature value indicating the actual surface temperature, but a brightness value indicating high and low heat as brightness, and has a non-linear relationship with the actual surface temperature. The reliable relationship between DN and the actual surface temperature is critical for a thermal image processing. We tested the relationship between the actual surface temperature and the DN value of the thermal image, and then the radiation adjustment was performed to better estimate actual surface temperatures. As a result, the relation graph between the actual surface temperature and the DN value similarly show linear pattern with the relation graph between the radiation-controlled non-contact thermometer and the DN value. And the non-contact temperature after adjusting the emissivity was closer to the actual surface temperature than before adjusting the emissivity.

An Experiment on Lighting Environment for some Behavior in Housing (주택에서의 각 생활행위에 대응하는 조명환경에 관한 실험연구)

  • Lee Sun-Young
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.65-71
    • /
    • 2005
  • The present study performed subjective evaluation experiments using slides and scale down models in order to propose guidelines for lighting environment desirable for each behavior in the house. The evaluation measure was composed of 20 mood items and 15 behavior items. As for experiment methods, the slide experiment used SD method, and the scale down model experiment used Scheffe's paired comparison. The results of this study are as follows. 1) Desirable lighting environment for working and talking is active atmosphere. 2) Lighting environment desirable far relaxation is to heighten lighting contrast using candescent lamps and local lights. In other words, active atmosphere, which is desirable for working and talking, is not desirable for relaxation. 3) Lighting for working requires bright illuminance and high color temperature(6000k). 4) Lighting for relaxation requires somewhat low brightness regardless of color temperature. If the light is bright it is better to use lamps of low color temperature. 5) for conversation, bright illuminance is more desirable than dark one, and the most adequate color temperature is 4000K.

The electrical and optical properties of Xe plasma in flat lamp (평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Chio, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Electrical and Optical Properties of Xe Plasma in Flat Lamp (평판형 광원에서 제논 플라즈마의 전기적 및 광학적 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.71-74
    • /
    • 2006
  • Discharge of the flat lamp lighting source research arc requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Electrical Properties of Plasma According to Gas Pressure and RF Power of Xe-Inductively Coupled Plasma (유도결합형 제논의 가스압력 및 RF전력에 따른 플라즈마의 전기적 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.43-47
    • /
    • 2006
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma (ICP). As results at several dependences of 20~100mTorr Xenon pressure, the brightness of discharge tube was higher (4,900 $cd/m^2$) than other conditions when Xe pressure was 20mTorr and RF power was 200W. In that case, the electron temperature and density were 3.58eV and $3.56{\times}10^{12}cm^2$, respectively. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF