• Title/Summary/Keyword: Breathing Detection

Search Result 46, Processing Time 0.021 seconds

Noise and Fault Diagnosis Using Control Theory

  • Park, Rai-Wung;Sul Cho
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 2000
  • The aim of this paper is to describe an advanced method of the fault diagnosis using Control Theory with reference to a crack detection, a new way to localize the crack position under influence of the plant disturbance and white measurement noise on a rotating shaft. As the first step, the shaft is physically modelled with a finite element method as usual and the dynamic mathematical model is derived from it using the Hamilton-principle and in this way the system is modelled by various subsystems. The equations of motions with a crack are established by the adaption of the local stiffness change through breathing and gaping[1] from the crack to the equation of motion with an undamaged shaft. This is supposed to be regarded as a reference system for the given system. Based on the fictitious model of the time behaviour induced from vibration phenomena measured at the bearings, a nonlinear state observer is designed in order to detect the crack on the shaft. This is the elementary NL-observer(EOB). Using the elementary observer, an Estimator(Observer Bank) is established and arranged at the certain position on the shaft. In case, a crack is found and its position is known, the procedure, fro the estimation of the depth is going to begin.

  • PDF

A Study on Classification and Localization of Structural Damage through Wavelet Analysis

  • Koh, Bong-Hwan;Jung, Uk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.754-759
    • /
    • 2007
  • This study exploits the data discriminating capability of silhouette statistics, which combines wavelet-based vertical energy threshold technique for the purpose of extracting damage-sensitive features and clustering signals of the same class. This threshold technique allows to first obtain a suitable subset of the extracted or modified features of our data, i.e., good predictor sets should contain features that are strongly correlated to the characteristics of the data without considering the classification method used, although each of these features should be as uncorrelated with each other as possible. The silhouette statistics have been used to assess the quality of clustering by measuring how well an object is assigned to its corresponding cluster. We use this concept for the discriminant power function used in this paper. The simulation results of damage detection in a truss structure show that the approach proposed in this study can be successfully applied for locating both open- and breathing-type damage even in the presence of a considerable amount of process and measurement noise.

  • PDF

Development of a Sleep-driving Accident Prevention System based on pulse

  • Bae, Seung-Woo;Seo, Jung-Hwa
    • Korean Journal of Artificial Intelligence
    • /
    • v.6 no.1
    • /
    • pp.11-15
    • /
    • 2018
  • The purpose of this study is to develop a pulsatile drowsiness detection system that can compensate the limitations of existing camera - based or breathing pressure sensor based Drowsiness driving prevention systems. A heart rate sensor mounted on the driver's finger and an alarm system that sounds when drowsiness is detected. The heart rate sensor was used to measure pulse changes in the wrist, and an alarm system based on the Arduino, which works in conjunction with the laptop, generates an audible alarm in the event of drowsiness. In this paper, we assume that the pulse rate of the drowsy state is 60 ~ 65 times / minute, which is the middle between the awake state and the sleep state. As a result of the experiment, the alarm sounded when the driver's pulse rate was in the drowsy pulse rate range. Based on these experiments, the drowsiness detection system was able to detect the drowsiness of the driver successfully in real time. A more effective drowsiness prevention system can be developed in the future by incorporating the results of the present study on a pulse-based drowsiness prevention system in an existing drowsiness prevention system.

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

A novel approach to damage localisation based on bispectral analysis and neural network

  • Civera, M.;Fragonara, L. Zanotti;Surace, C.
    • Smart Structures and Systems
    • /
    • v.20 no.6
    • /
    • pp.669-682
    • /
    • 2017
  • The normalised version of bispectrum, the so-called bicoherence, has often proved a reliable method of damage detection on engineering applications. Indeed, higher-order spectral analysis (HOSA) has the advantage of being able to detect non-linearity in the structural dynamic response while being insensitive to ambient vibrations. Skewness in the response may be easily spotted and related to damage conditions, as the majority of common faults and cracks shows bilinear effects. The present study tries to extend the application of HOSA to damage localisation, resorting to a neural network based classification algorithm. In order to validate the approach, a non-linear finite element model of a 4-meters-long cantilever beam has been built. This model could be seen as a first generic concept of more complex structural systems, such as aircraft wings, wind turbine blades, etc. The main aim of the study is to train a Neural Network (NN) able to classify different damage locations, when fed with bispectra. These are computed using the dynamic response of the FE nonlinear model to random noise excitation.

Respiration and Heartbeat detection algorithm using UWB radar (UWB 레이더를 사용한 호흡 및 심박 감지 알고리즘)

  • Le, Minhhuy;Hwang, Lan-mi;Fedotov, Dmitry
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2019
  • Ultra Wideband (UWB) Radar is a high-resolution radar for short distance detection which uses signals transmitted and received by each antennas in order to detect a target. It is possible to detect the respiration and heartbeat of a person without contact It is getting more and more often utilized since it is not affected by physical environment. In this paper, we implement an algorithm to detect human respiration and heartbeat rate using UWB radar signal. We process radar signals reflected from human body using Median filter, Kalman filter, Band Pass filter and so on. We also use CZT to extract breathing and heart rate. ECG (Electrocardiogram) was used for comparison of heartbeat data and we confirm that each data of ECG and UWB Radar were more than 98% identical each other.

Sleep Monitoring by Contactless in daily life based on Mobile Sensing (모바일 센싱 기반의 일상생활에서 비접촉에 의한 수면 모니터링)

  • Seo, Jung-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.491-498
    • /
    • 2022
  • In our daily life, quality of sleeping is closely related to happiness index. Whether or not people perceive sleep disturbance as a chronic disease, people complain of many difficulties, and in their daily life, they often experience difficulty breathing during sleep. It is very important to automatically recognize breathing-related disorders during a sleep, but it is very difficult in reality. To solve this problem, this paper proposes a mobile-based non-contact sleeping monitoring for health management at home. Respiratory signals during the sleep are collected by using the sound sensor of the smartphone, the characteristics of the signals are extracted, and the frequency, amplitude, respiration rate, and pattern of respiration are analyzed. Although mobile health does not solve all problems, it aims at early detection and continuous management of individual health conditions, and shows the possibility of monitoring physiological data such as respiration during the sleep without additional sensors with a smartphone in the bedroom of an ordinary home.

Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.269-272
    • /
    • 2004
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

  • PDF

A pressure sensor system for detecting driver's drowsiness based on the respiration Paper Template for the KITS Review (호흡기반 운전자 졸음 감지를 위한 압력센서 시스템)

  • Kim, Jaewoo;Park, Jaehee;Lee, Jaecheon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.45-51
    • /
    • 2013
  • In this paper, a driver's drowsy detection sensor system based on the respiration is investigated. The sensor system consists of a piezoelectric pressure sensor attached at the abdominal region of the seat belt and a personal computer. The piezoelectric pressure sensor was utilized for the measurement of pressure variations induced by the movement of the driver abdomen during breathing. The signal processing software for detecting driver's drowsiness was produced using the Labview. The experiments were performed with 30 years male driver. The amplitude of the respiration at awake state was larger than one at the drowsy state. On the contrary, the respiration rate at awake state was lower than one at the drowsy state. The drowsy detection sensor system developed based on the experimental could successfully detect the driver's drowsy on real-time.

A Study on the Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상 연구)

  • Han, Seung-Heon;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.204-209
    • /
    • 2005
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.