• 제목/요약/키워드: Breast implant complication

검색결과 39건 처리시간 0.026초

A Forgotten Entity following Breast Implant Contracture: Does Baker Need a Change?

  • Pagani, Andrea;Aitzetmuller, Matthias M.;Larcher, Lorenz
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.360-364
    • /
    • 2022
  • Although capsular contracture represents one of the most important complications after breast augmentation, local inflammation and fibrosis can lead, to capsular calcification, an often-forgotten radiological sign of capsular contracture. In this article, the authors present a clinical case of breast implant calcification in an 81-year-old patient. Although this complication has been rarely described, the literature was reviewed to clarify the role of the local microenvironment in capsular contracture and calcification. At present, capsular contracture patients are classified using the conventional Baker score and the histological Wilflingseder classification. As it was not possible to consider capsular calcification when classifying our patient using the traditional scores, the authors propose an updated version of the current scale.

Outcome of complete acellular dermal matrix wrap with polyurethane implant in immediate prepectoral breast reconstruction

  • Naemonitou, Foteini;Mylvaganam, Senthurun;Salem, Fathi;Vidya, Raghavan
    • Archives of Plastic Surgery
    • /
    • 제47권6호
    • /
    • pp.567-573
    • /
    • 2020
  • Background Polyurethane implants have been used on and off in breast reconstruction since 1991 while prepectoral breast reconstruction has gained popularity in recent times. In this study, we present our outcomes from the use of acellular dermal matrix (ADM) complete wrap with polyurethane implants in prepectoral breast reconstruction. Methods This is a retrospective review of prospectively maintained database from 41 patients receiving complete ADM wrap with prepectoral polyurethane implants over a 3-year period. Selection criteria were adapted from a previous study (4135 Trust Clinical Audit Database) evaluating prepectoral reconstruction with Braxon matrices. Patient demographics, operative data, surgical complications, and outcomes were collected and analyzed. Results A total of 52 implant reconstructions were performed in 41 patients with a mean follow-up of 14.3 months (range, 6-36 months). The overall reported complication rates including early (less than 6 weeks) and late complications. Early complications included two patients (4.9%) with wound dehiscence. One of which had an implant loss that was salvageable. Another patient (2%) developed red-breast syndrome and two women (4.9%) developed with seroma treated conservatively. Late complications included one patient (2%) with grade II capsular contraction, 12 patients with grade I-II rippling and two patients (4.9%) with grade III rippling. Conclusions We present our experience of prepectoral polyurethane implant using complete ADM wrap. This is one of the few papers to report on the outcome of the prepectoral use of polyurethane in immediate implant-based breast reconstruction. Our early observational series show satisfactory outcome and long-term results are warranted by a large multicenter study.

유방암 환자에서 피부보존 유방절제술 후 실리콘 보형물을 이용한 즉시 유방재건술 (Immediate Implant Reconstruction using Silicone Prosthesis in Breast Cancer Patients after Skin Sparing Mastectomy)

  • 조영규;양정덕;김귀락;정호윤;조병채;박호용
    • Archives of Plastic Surgery
    • /
    • 제37권6호
    • /
    • pp.749-757
    • /
    • 2010
  • Purpose: Since skin sparing mastectomy removes the mammary gland and the nipple-areolar complex preserving all mammary skin, it makes the widespread use of implants in immediate reconstruction. This article reports our experience in immediate breast reconstruction after skin sparing mastectomy by using the silicone implants in patients especially who have small to moderate sized and minimal ptotic breast. Methods: From September of 2007 to July of 2009, we performed breast reconstruction for 44 breasts of 40 women with silicone implant after mastectomy. Tumors were divided into 5 malignant types (21 IDC, 18 DCIS, 2 ILC, 2 phylloides tumor, 1 mucinous carcinoma). The implant is placed in a submuscular pocket or in a submuscularsubfascial pocket depending upon the condition of the muscles and skin flaps after mastectomy. Results: The mean age was 47 years and the average follow-up period was 11 months. Cosmetic outcome was assessed by evaluation of photographs and assessment of breast volume and shape, breast symmetry, and overall outcome. About 80% of each of these parameters was scored as good or excellent. Breast complication was developed in a total of 6 cases including 2 capsular contracture, 2 partial skin necrosis due to blue dye injection and 2 implant infection. Conclusion: The use of definitive implants in a skin sparing mastectomy is a one-stage immediate breast reconstruction with low morbidity and acceptable result. This method is considered reliable with favorable aesthetic result.

A Retrospective Analysis of Ruptured Breast Implants

  • Baek, Woo Yeol;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.734-739
    • /
    • 2014
  • Background Rupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants. Methods We performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone), duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management. Results Forty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case), microfat graft (2 case), removal only (14 case), and follow-up loss (17 case). Conclusions Saline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

Comparison of Outcomes in Immediate Implant-Based Breast Reconstruction: Acellular Dermal Matrix versus Inferior Dermal Flap

  • Ribeiro, Luis Mata;Meireles, Rita P.;Brito, Iris M.;Costa, Patricia M.;Rebelo, Marco A.;Barbosa, Rui F.;Choupina, Miguel P.;Pinho, Carlos J.;Ribeiro, Matilde P.
    • Archives of Plastic Surgery
    • /
    • 제49권2호
    • /
    • pp.158-165
    • /
    • 2022
  • Background Implant-based breast reconstruction has evolved tremendously in the last decades, mainly due to the development of new products and techniques that make the procedure safer and more reliable. The purpose of this study was to compare the outcomes in immediate one-stage breast reconstruction between acellular dermal matrix (ADM) and inferior dermal flap (IDF). Methods We conducted a retrospective comparative study of patients submitted to immediate breast reconstructions with an anatomical implant and ADM or IDF in a single center between 2016 and 2018. Outcomes evaluated included major complications, early complications, reinterventions, readmissions, and reconstruction failure. Simple descriptive statistics and univariate analysis were performed. Results A total of 118 breast reconstructions (85 patients) were included in the analysis. Patients in the IDF group had a higher body mass index (median = 27.0) than patients in the ADM group (median = 24). There were no statistically significant differences among both groups regarding immediate major complication, early complications, readmissions, and reinterventions. Conclusion There are no significant differences in complications between the ADM and IDF approach to immediate implant breast reconstruction. In patients with higher body mass index and large, ptotic breasts, we recommend an immediate implant reconstruction with IDF.

변형 근치 유방절제술 후 Becker 확장형 보형물을 이용한 유방 재건술 (Breast Reconstruction after Modified Radical Mastectomy with Becker Permanent Tissue Expander)

  • 홍용택;윤을식;최규진;동은상;손길수
    • Archives of Plastic Surgery
    • /
    • 제34권2호
    • /
    • pp.222-228
    • /
    • 2007
  • Purpose: Report of the good results of breast reconstruction using Becker permanent tissue expander that showed a short operation time and a quick post-operation recovery time, little side effects and usually superb aesthetic results without the need for additional incisions or donor site morbidity. The authors, after carrying out breast reconstruction operations using Becker permanent tissue expander on patients with appropriate indications, attempted to analyze several factors such as complication rates and patient satisfaction measurements. Methods: 11 cases of breast reconstruction using Becker expander implants were carried out on a total of 10 patients between March 2000 and February 2003. The patients were followed up at outpatient visit for an average of 6 months. Results: The most common post-operation complication was pain resulting from saline injection into the expanders, complained by 5 patients(50%). rib fractures, skin necrosis, implant removal due to infection, and breast cancer recurrence each occurred in 1 patient (9.9%). There was no occurrence of skin contracture complications which occurs frequently in case of silicone implant insertion. Patient complacency was surveyed by patient interviews made right after the operations and during outpatient follow-up periods: 5(50%) patients out of 10 showed excellent, 3(30%) good, and 2(20%) showed fair, leaving no patients who were disappointed with operation results. On routine follow-up, 80% of patients expressed satisfaction with the cosmetic outcome of their post-mastectomy beast reconstruction. Conclusion: Breast reconstruction using the Becker expander is a reliable alternative to other reconstructive methods but good patient selection is essential for satisfactory results.

유방 증대술 후 후기 혈종 발생례 (Late Hematoma after Breast Augmentation)

  • 김기갑;민경원;장성수;허찬영
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.767-769
    • /
    • 2005
  • Late capsular hematoma is one of the rare complication of augmentation mammoplasty. Although the cause has not unfolded yet, the possible damage of capsular vessels chafed against the textured prostheses is questioned. Reviewing the literatures, we present a 23-year-old female subjects to incidental swelling of the right breast a year later after augmentation mammaplasty with saline-filled textured prostheses. An MRI study confirmed intracapsular fluid collection sparing the prostheses. The exploration was followed and serosanguinous fluids was drained out of the intracapsular space, and then the existing prostheses were replaced with the smooth surface ones. In the 9 months since the last surgery the patient remained well without any further problem. Intensive massage of the breasts might be accounted to the probable cause of late hematoma in this case.

Tabbed Tissue Expanders Improve Breast Symmetry Scores in Breast Reconstruction

  • Khavanin, Nima;Gust, Madeleine J.;Grant, David W.;Nguyen, Khang T.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • 제41권1호
    • /
    • pp.57-62
    • /
    • 2014
  • Background Achieving symmetry is a key goal in breast reconstruction. Anatomically shaped tabbed expanders are a new tool in the armamentarium of the breast reconstruction surgeon. Suture tabs allow for full control over the expander position and thus inframammary fold position, and, in theory, tabbed expanders mitigate many factors responsible for poor symmetry. The impact of a tabbed expander on breast symmetry, however, has not been formally reported. This study aims to evaluate breast symmetry following expander-implant reconstruction using tabbed and non-tabbed tissue expanders. Methods A chart review was performed of 188 consecutive expander-implant reconstructions that met the inclusion criteria of adequate follow-up data and postoperative photographs. Demographic, oncologic, postoperative complication, and photographic data was obtained for each patient. The photographic data was scored using a 4-point scale assessing breast symmetry by three blinded, independent reviewers. Results Of the 188 patients, 74 underwent reconstruction with tabbed expanders and 114 with non-tabbed expanders. The tabbed cohort had significantly higher symmetry scores than the non-tabbed cohort ($2.82/4{\pm}0.86$ vs. $2.55/4{\pm}0.92$, P=0.034). Conclusions The use of tabbed tissue expanders improves breast symmetry in tissue expander-implant-based breast reconstruction. Fixation of the expander to the chest wall allows for more precise control over its location and counteracts the day-to-day translational forces that may influence the shape and location of the expander pocket, mitigating many factors responsible for breast asymmetry.

보형물을 이용한 유방성형술을 동반한 역복부성형술의 치험례 (Reverse Abdominoplasty with Augmentation Mammoplasty Using Breast Implant: A Case Report)

  • 배인호;이윤호
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.535-538
    • /
    • 2011
  • Purpose: The reverse abdominoplasty has been reported infrequently as a procedure to improve the upper abdominal wall contour. Especially, there have been rare cases on the surgical techniques with augmentation mammoplasty using implant. It is known to maintain the result. Methods: This is a retrospective review of the senior surgeon's patients who underwent reverse abdominoplasty with augmentation mammoplasty. A 63-year-old female was dissatisfied with her contracted breast and upper abdominal contour after previous abdominal wall liposuction. We performed reverse abdominoplasty with augmentation mammoplasty through same inframammary incision. Results: There was a significant improvement of the upper abdominal wall and breast contour. There was no perioperative complication. The patients was satisfied with the results and retained a good shape during the 3 months follow-up periods. Conclusion: Reverse abdominoplasty with augmentation mammoplasty is an acceptable technique that provides good results and should be considered in cases of upper abdominal laxity with capsular contracture on both breasts.

Characteristics of adhesion areas between the tissue expander and capsule in implant-based breast reconstruction

  • Lim, Yoon Min;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Roh, Tai Suk;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.330-335
    • /
    • 2019
  • Background The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. Methods Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. Results Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). Conclusions We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.