• Title/Summary/Keyword: Breast dose

Search Result 540, Processing Time 0.028 seconds

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

Inactivated Sendai Virus Strain Tianjin Induces Apoptosis in Human Breast Cancer MDA-MB-231 Cells

  • Chen, Jun;Han, Han;Chen, Min;Xu, Xiao-Zhu;Wang, Bin;Shi, Li-Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.5023-5028
    • /
    • 2014
  • Sendai virus strain Tianjin is a novel genotype. Here, we investigate the antitumor and proapoptotic effects of ultraviolet-inactivated Sendai virus strain Tianjin (UV-Tianjin) on human breast cancer MDA-MB-231 cells in vitro, as well as the involvement of the apoptotic pathway in the mechanism of UV-Tianjin-induced antitumor effects. MTT assays showed that treatment with UV-Tianjin dose-dependently inhibited the proliferation of MDA-MB-231 cells but not normal MCF 10A breast epithelium cells. Hoechst staining and flow cytometric analysis revealed that UV-Tianjin induced apoptosis of MDA-MB-231 cells in a dose-dependent manner. Moreover, UV-Tianjin treatment resulted in reduction in the mitochondria membrane potential (MMP) and release of cytochrome complex (cyt c) via regulation of Bax and Bcl-2, as well as activation of caspase-9, caspase-3, Fas, FasL and caspase-8 in MDA-MB-231 cells. In summary, our study suggests that UV-Tianjin exhibits anticancer activity in human breast cancer MDA-MB-231 cells through inducing apoptosis, which may involve both the endogenous mitochondrial and exogenous death receptor pathways.

Silibilin-Induces Apoptosis in Breast Cancer Cells by Modulating p53, p21, Bak and Bcl-xl Pathways

  • Pirouzpanah, Mohammad Bagher;Sabzichi, Mehdi;Pirouzpanah, Saeed;Chavoshi, Hadi;Samadi, Nasser
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.2087-2092
    • /
    • 2015
  • Nowadays herbal-derived medicines are attracting attention as new sources of drugs with few side effects. Silibinin is a flavonoid compound with chemotheraputic effects on different cancers such as examples in the prostate, lung, colon and breast. In the present study, the cytotoxic effects of silibinin on MCF7 breast cancer cells were investigated. Apoptosis was determined by flow cytometry and the impact of silibinin on the expression of pivotal genes including Bak, P53, P21, BRCA1, BCL-X1 and ATM was analyzed. Treatment for 24h had a significant dose-dependent inhibitory effect on cell growth (p<0.05) with dose- and time- dependent induction of apoptosis (p<0.05). In addition, there were significant increases in BRCA1, ATM, Bak and Bcl-XL gene expression at the mRNA level with different concentrations of silibinin for 24 or 48 h (p<0.05). Taken together, the results suggest that silibinin inhibits the proliferation and induces apoptosis of MCF-7 cells by down-regulating Bak, P53, P21, BRCA1, BCL-Xl and thus may be considered as an effective adjuvant drug to produce a better chemopreventive response for the cancer therapy.

A Study of Radiographic Condition in the Mammography (유방 X선촬영 실태에 관한 조사연구)

  • Lee, In-Ja;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.55-61
    • /
    • 2000
  • This report was the results of an investigation based on the status of the mammography in the 45 medical facilities in the areas of Seoul and Kyong-Gi Do. In regard to mammography we were able to understand the rectification method of the generator, the functions, the radiographic techniques, the patient exposure dose, etc. Recently, the occurrence of breast cancer has rapidly increased and has lead to increased interest in the early discovery of breast cancer. However, mammography has not kept up with the publics interests and its demand. The main problem is thought to be a wide great difference in the quality of the facilities, especially in the techniques of radiograpic and the capabilities of the generator, which would have a major effect on the grade management of the image quality. In order to be ready and keep up with the high rate of increase of breast cancer, the standardization of mammography and the grade management is urgently required as a solution to the problems in the increase of image qualify and the decrease of dose. It is regarded that the basic guide of the techniques of photography in the mammography, which is being used in all developed countries due to the influence of the USA, should be presented, especially in Korea, and for this, more active and enthusiastic education and enlightenment should be needed.

  • PDF

Anti-proliferative effect of Sam-nueng(Sparganii Rhizoma) extract on MCF-7 cells (삼릉(三稜) 추출물의 인간 유방암 세포 성장 억제 효과)

  • Park, Kyong-Mi;Cho, Sung-Hee;Jeong, Kyoung-Ah
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.1
    • /
    • pp.166-177
    • /
    • 2006
  • Purpose : This investigation was undertaken to evaluate the antiproliferation, atoptosis of Sam-nueng(Sparganii Rhizoma) extract using MCF-7 human breast cancer cells. Methods : MCF-7 cells were cultured in Dulbecco's modified Eagle's medium/F12(DMEM/F12) supplemented with 10 % fetal bovine serum(FBS; Gibco) and antibiotics. At varying times after extract treatment, cells were harvested with scraper and processed for analysis of protein expression, proliferation, cytotoxicity and apoptosis. Results : Our results show that the extract of Sam-nueng(Sparganii Rhizoma) strongly inhibits the proliferation of MCF-7 cells in a dose and time-dependent manner. Sulforhodamine B showed that the addition of Sam-nueng(Sparganii Rhizoma) extract reduced the viability of MCF-7 cells in a dose-dependent manner. Poly[ADP(ribose)] polymerase(PARP) which serves as a marker of cells undergoing apoptosis, a major substrate for caspase-3 was extensively cleaved in the Sam-nueng(Sparganii Rhizoma)-treated cells. Conclusion : So, we can conclude that Sam-nueng(Sparganii Rhizoma) can have an inhibitive effect on MCF-7 human breast cancer cells by variable mechanisms.

  • PDF

Inhibition of Cellular Proliferation by CURCUMAE LONGAE Rhizoma Extracts on MCF-7 (강황(薑黃) 추출물이 유방암 세포주 MCF-7 증식 억제에 미치는 영향)

  • Jung, Sun;Kim, Hyung-Woo;Park, Ji-Eun;Kim, Young-Gyun;Cho, Su-In
    • The Korea Journal of Herbology
    • /
    • v.21 no.1
    • /
    • pp.71-77
    • /
    • 2006
  • Objectives : This investigation was undertaken to evaluate the anti-proliferation of CURCUMAE LONGAE Rhizoma extracts using MCF-7, human breast cancer cells. Methods : MCF-7 cells were cultured in Dulbecco's modified Eagle's medium/F12 supplemented with 10% fetal bovine serum and antibiotics. At varying times after extract treatment, cells were harvested with scraper and processed for analysis of proliferation, cytotoxicity. Results : The extract of CURCUMAE LONGAE Rhizoma strongly inhibits the proliferation of MCF-7 cells in a dose and time-dependent manner. Sulforhodamine B assay showed that the addition of ethanol extract of CURCUlVIAE LONGAE Rhizoma reduced the viability of MCF-7 cells in a dose-dependent manner. Conclusion : So, it can be concluded that CURCUMAE LONGAE Rhizoma have an inhibitive effect on MCF-7 human breast cancer cells.

  • PDF

The Cell Cycle Regulatory Effects of High Dose 5-fluorouracil on Breast Cancer Cell Line (유방암세포주에서 고농도 5-fluorouracil의 세포주기 조절효과)

  • Jang, Joung Soon;Yang, Jung Ill;Chang, Seho;Lee, Won Sup;Lee, Jong Seok;Ahn, Myung-Ju;Park, Byung-Kiu
    • IMMUNE NETWORK
    • /
    • v.2 no.1
    • /
    • pp.60-64
    • /
    • 2002
  • Background: Chemotherapy with 5-fluorouracil (5-FU) has been one of the mainstay in breast cancer treatment. The effects of high dose 5-FU on cell cycle regulation were studied in breast caner cells. Methods: A breast cancer cell line MCF-7 was used. Protein expressions of G1/S cyclins, $p21^{Waf1/Cip1}$, cdk2, E2F1 and retinoblastoma were tested by western blot analysis. Immunoprecipitation and immune complex kinase assay were done for the assessment of E2F1/RB interacton and the activity of cdk2 respectively. Results: $p21^{Waf1/Cip1}$ expression was barely detectable in control cells. With addition of 5-FU level of $p21^{Waf1/Cip1}$ were induced and cyclin D3 level was decreased as cell growth decreases. In accordance with increased expression of $p21^{Waf1/Cip1}$, cyclin E-associated cdk2 kinase activity was reduced. Retinoblastoma protein (RB) became dephosphorylated and E2F-1 binding activity with RB was increased. Conclusion: In this situation of high concentration of 5-FU breast cancer cells tend to be G1/S cell cycle arrested. Overexpression of $p21^{Waf1/Cip1}$ and dephosphorylation of RB may mediate the effectss of 5-FU by inhibiting E2F-1 activity, which contributes to G1/S cell cycle arrest. These results could be an indicating landmark for further study of high dose chemotherapy with 5-FU.

Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation (부분유방방사선치료(Accelerated Partial Breast Irradiation) 환자의 장액종(Seroma) 체적 변화에 대한 연구)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.65-75
    • /
    • 2016
  • Purpose : By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Materials and Methods : Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. Results : The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. Conclusion : As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  • PDF

A study on Dose of the Junction in Radiotherapy of Breast Cancer including SCL. (쇄골상부림프절을 포함한 유방암 방사선 치료 시 접합부 선량에 관한 고찰)

  • Jung, Woo Hyun;Hong, Joo Wan;Won, Hui Su;Chang, Nam Jun;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.93-100
    • /
    • 2017
  • Purpose: A purpose of this study was to compare dose of junction between breast and SCL fields in radiation therapy by MLC located at the junction. Materials and Methods: With 6 MV of 21EX-S equipped with 120-leaf Millennium MLC, treatment plans were designed with 30 patients who underwent radiation therapy using TFT. Plan 1 where the MLC was all used at the junction. In plan 2 and plan 3, MCLs were retracted 5 mm from breast and SCL, respectively. Plan 4 with all of MLC retracted at the junction were designed. In all of the plans, collimator angle for SCL field was divided into $0^{\circ}$ and $270^{\circ}$. To verify junction dose, the dose at 3cm depth of junction was compared with average value by MapCHECK. Results: In case of the SCL field with $0^{\circ}$ collimator angle, average value of D3cm was 4131.1, 4215.9, 4351.4, and 4423.0 cGy. In case of the SCL field with $270^{\circ}$ collimator angle, average value of D3cm was 4044.3, 4246.7, 4291.1, and 4441.2 cGy. In plan1 and 3, change in average dose depending on collimator angle was changed more significantly than paln2 and 4. Dose measured at 3cm depth of junction was similar to treatment plan. Conclusion: In radiation therapy plan for breast cancer with SCL, retracting MLCs from junction between breast and SCL fields will lead to decrease effect of dose of the junction.

  • PDF

The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery (좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰)

  • Kim, Tae Min;Moon, Sung Kong;Kim, Li Zzy;Kim, Se Young;Park, Ryeung Hwang;Kim, Joo Ho;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose : We retrospectively analyzed doses of each radiation therapy technique used in the treatment for left breast cancer patients after partial mastectomy through dose results for normalorgans and tumor volume to use this as a clinical reference for radiation therapy of domestic left breast cancer patients. Materials and Methods : 40 patients who underwent partial mastectomy on left breast cancer were classified in 3 treatment methods. The treatment plan was evaluated by HI(homogeneity index), $D_{95%}$, and CI(conformity index), and the $V_{hot}$ for gross tumor volume and clinical target volume of each treatment method. In Cyberknife treatment, tumor volume was the same as high dose volume in the other techniques, so no consideration was given to clinical target volume. Treatment plan evaluation for normal organs were evaluated by mean dose on ipsilateral lung, heart, left anterior descending artery, opposite breast and lung, and non-target tissue. Result : Treatment with volumetric arc radiotherapy(VMAT) showed $95.84{\pm}0.75%$ of $D_{95%}$ on the clinical target volume, significantly higher than that of 3D-CRT. The $D_{95%}$ value of the total tumor volume was slightly higher than the other treatments. In Cyberknife treatment, the dose to the normal organs was significantly lower than other treatments. Overall, the maximum dose and mean dose to the heart were $26.2{\pm}6.12Gy$ and $1.88{\pm}0.2Gy$ in VMAT treatment and $20.25{\pm}9.35Gy$ and $1.04{\pm}0.19Gy$ in 3D-CRT therapy, respectively. Conclusion : In comparison on 3D-CRT and VMAT, most of the dosimetric parameters for the evaluation of the treatment plan showed similar values, so that there is no significant difference in treatment plan evaluation. It is possible to select the treatment method according to the patient's anatomical structure or possibility of breath control. Cyberknife treatment is very useful treatment for normal organs because of its accurate dose exposure to the tumor volume However, it has restrictions to treat the local area, to have relatively long treatment time and to involve invasive procedure.

  • PDF