• 제목/요약/키워드: Breakwater width

검색결과 72건 처리시간 0.026초

천해역에 방류되는 원형 다공바닥젵의 유속구조 (Velocity Structure of Wall Jet Originating from Circular Orifices in Shallow Water)

  • 김대근;서일원
    • 한국환경과학회지
    • /
    • 제11권10호
    • /
    • pp.1039-1044
    • /
    • 2002
  • In this study, breakwater model which has several outlet pipes to discharge water is settled in the experimental open channel and mean velocity distributions of multi wall jet are measured. The length of zone of flow establishment of wall jet is shorter than that of free jet and decay rate of jet centerline longitudinal velocity along x is linear in $0.3{leq}x/I_p{leq}17$. The rate of vertical width and lateral width spreading of multi wall jet is respectively 0.0753, 0.157.

설상사주 형성조건 하에 있는 3차원투과성잠제 주변에서 내부유속변동의 특성 (Characteristics of Velocity Fields around 3-Dimensional Permeable Submerged Breakwaters under the Conditions of Salient Formation)

  • 이광호;배주현;안성욱;김도삼
    • 한국해안·해양공학회논문집
    • /
    • 제29권6호
    • /
    • pp.399-409
    • /
    • 2017
  • 본 연구는 투과성잠제 배후에서 형성되는 설상사주의 주요외력으로 작용하는 평균유속, 연안류 및 난류운동에너지 등을 포함한 유속장의 특성을 수치적으로 검토하였다. 또한, 연안류에 의한 수송유량으로부터 해안선의 지형변동도 예측하였다. 수치해석에는 오픈소스 CFD 코드인 OLAFOAM에 기초한 3차원수치파동수조에 설상사주의 형성조건 하에 있는 투과성잠제를 설치하여 수치실험을 수행하였다. 수치실험에서는 규칙파의 조건 하에서 잠제의 개구폭 및 설치위치에 따른 잠제 주변에서 유속변동의 특성을 평가하였다. 수치실험 결과로부터 잠제의 개구폭이 넓을수록 강한 연안류가 형성됨과 동시에 수송유량이 증가하고, 개구폭이 좁을수록 연안류가 수렴되는 지점이 제간부에서 제두부로 이동함을 확인하였으며, 이로부터 잠제 배후에 형성되는 설상사주의 형성원인을 파악할 수 있었다. 또한, 잠제 사이의 개구폭 및 잠제와 해안선 사이의 거리에 따라 연안류는 해안선에서 난류운동에너지의 변화와 밀접한 관계를 가지는 것을 알 수 있었다.

3차원파동장에 있어서 대형연직케이슨에 작용하는 선형 및 비선형의 파압분포특성에 관한 연구 (Linear and Nonlinear Wave Pressure Distributions Acting on Vertical Caisson of Large Size in 3-Dimensional Wave Fields)

  • 김도삼;신동훈;이봉재
    • 한국해양공학회지
    • /
    • 제15권3호
    • /
    • pp.114-119
    • /
    • 2001
  • Goda formula (Goda, 1973) has been used in the determination of wave pressures acting on a large size caisson such as the pier of the cable stayed bridge at sea. Goda formula, however, is to evaluate the wave pressures acting the infinite vertical caisson of composite breakwater so that it can`t be applied to a large caisson with finite width and length because of diffraction effects. In the present study, three dimensional nonlinear frequence domain method based on perturbation method and boundary integral method is applied to the computation of the linear and nonlinear wave pressures acting on the front of a large size caisson under the variation of its width and length, and angle of incident wave. The numerical results are compared to Goda\`s ones, and then the characteristics of wave pressure distributions acting on a large size caisson are discussed.

  • PDF

부분 유공 케이슨 방파제로부터의 파의 반사 (Wave Reflection from Partialy Perforated Caisson Breakwater)

  • Suh, Kyung-Doug
    • 한국해안해양공학회지
    • /
    • 제8권3호
    • /
    • pp.221-230
    • /
    • 1996
  • 기존의 전유공 케이슨 방파제로부터의 파 반사를 계산하기 위하여 개발된 Suh and Park의 이론 모형을, 케이슨 전면 하부의 연직벽을 경사가 매우 급한 경사벽으로 가정함으로써, 부분 유공 케이슨 방파제에 적용하였다. 또한, 이 모형에서, Kano and Liu가 제안한 차단계수를 이용하여 유공벽에서의 관성저항항을 수정하였다. 이 모형을 1993년도에 보고된 Park et al.의 수리실험 자료와 비교해 본 결과, 실험 자료 및 이론 모형 결과에서 모두 관성저항의 영향이 중요하여 B/L$_{c}$가 약 0.2일 때 반사율이 최소가 됨을 보이는데 (여기서 B=유수실의 폭, L$_{c}$=유수설 내에서의 파장), 이 값은 찬성저항의 영향을 무시했을 때 얻어지는 값 0.25보다 약간 작은 값이다. 또한 선형파 이론에 근거한 이 모형은 파의 비선형성이 증가함에 따라 반사율을 크게 계산하는 경향이 있음을 보이며, 따라서 이 모형은 파형경사가 작은 통상파에 적용하는 것이 바람직함을 알 수 있었다.있었다.

  • PDF

Experimental study on the method of estimating the vertical design wave force acting on a submerged dual horizontal plate

  • Kweon, Hyuck-Min;Oh, Sang-Ho;Choi, Young-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권4호
    • /
    • pp.569-579
    • /
    • 2013
  • A steel-type breakwater that uses a submerged dual horizontal porous plate was originally proposed by Kweon et al. (2005), and its hydrodynamic characteristics and design methodology were investigated in a series of subsequent researches. In particular, Kweon et al. (2011) proposed a method of estimating the vertical uplift force that acts on the horizontal plate, applicable to the design of the pile uplift drag force. However, the difference between the method proposed by Kweon et al. (2011), and the wave force measured at a different time without a phase difference, have not yet been clearly analyzed. In this study, such difference according to the method of estimating the wave force was analyzed, by measuring the wave pressure acting on a breakwater model. The hydraulic model test was conducted in a two-dimensional wave flume of 60.0 m length, 1.5 m height and 1.0 m width. The steepness range of the selected waves is 0.01~0.03, with regular and random signals. 20 pressure gauges were used for the measurement. The analysis results showed that the wave force estimate in the method of Kweon et al. (2011) was smaller than the wave force calculated from the maximum pressure at individual points, under a random wave action. Meanwhile, the method of Goda (1974) that was applied to the horizontal plate produced a smaller wave force, than the method of Kweon et al. (2011). The method of Kweon (2011) was already verified in the real sea test of Kweon et al. (2012), where the safety factor of the pile uplift force was found to be greater than 2.0. Based on these results, it was concluded that the method of estimating the wave force by Kweon et al. (2011) can be satisfactorily used for estimating the uplift force of a pile.

잠제 설치 연안의 처오름 높이 특성 ; PART II - 잠제의 제원에 의한 영향 (Characteristics of Run-up Height over Sandy Beach with Submerged Breakwaters ; PART II - Effect of Shape of Submerged Breakwaters)

  • 허동수;이우동
    • 대한토목학회논문집
    • /
    • 제28권4B호
    • /
    • pp.429-439
    • /
    • 2008
  • 본 연구에서는 잠제의 제원(천단수심, 천단폭, 사면경사, 제장)에 따라 해빈상을 전파하는 풍파의 처오름 높이 변화특성을 논의하기 위하여, 기존의 수리모형 실험치와 계산치를 비교 검토를 통해 타당성과 유효성이 검증된 수치모델로서, 파 투과성구조물 해빈의 상호간섭을 직접 해석할 수 있는 3D-수치모델(LES-WASS-3D; 허와 이, 2007)을 이용하여 잠제 2기의 제원에 따른 수치시뮬레이션을 실시하였다. 그 결과 천단수심, 천단폭, 사면경사, 제장의 변화가 연안에서의 처오름 높이에 미치는 영향에 관하여 검토하였으며, 아울러, 잠제 주변의 파고분포 및 상층흐름특성과의 관계에 대해서도 논의하였다.

수평형(水平型) 이열(二列) 조합판(組合板)의 투과율(透過率) 산정(算定)을 위한 실험적(實驗的) 연구(硏究) (Experimental Study on Energy Transmission Rate of Horizontal Dual Plate by Random Wave System)

  • 권혁민;김영학;기성태
    • 대한토목학회논문집
    • /
    • 제28권4B호
    • /
    • pp.421-428
    • /
    • 2008
  • 최근 들어 우리나라 전해역에 걸쳐 발생하고 있는 침식은 사회적인 문제가 되어왔다. 하지만, 해안구조물에 의한 기존의 방법으로 해안선을 보호하는 것이 "파랑장에 친화적인가?"라는 관점에서 개선의 여지가 있다. 새로운 형식의 철재형 이안제는 권혁민 등(2007)에 의해 제안되었다. 본 형식은 다수의 파일과 상부에 파랑진행방향과 수평으로 설치된 소파장치로 구성되어 있다. 본 형식은 해수유통원활, 대수심 축조수월, 공기단축 등의 장점이 있다. 본 연구는 소파제로서 철재형 이안제의 상부에 거치가 가능한 이열 조합판의 투과율을 실험적으로 평가했다. 일방향 불규칙파 시스템에 의한 모형실험을 통하여 반사율, 소파율, 투과율에 관하여 분석했다. 실험결과, 파형경사가 클수록 그리고 조합판의 폭-파장비가 클수록 투과율이 작아짐을 보였다. 본 연구는 이열 소파판 조합에 대하여 투과율 산정을 위한 직선식을 제안했다.

2차원 유한요소법을 이용한 불투과성 사각형 수중방파제의 Bragg 반사 해석 (Analysis of Bragg Reflection of Waves due to Rectangular Impermeable Submerged Breakwaters with Two-Dimensional Finite Element Method)

  • 조용식;정우창
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.447-454
    • /
    • 2003
  • 본 연구에서는 유한요소법을 이용하여 일정 수심상에서 사각형 형상의 불투과성 수중방파제에 의한 파랑의 Bragg 반사를 수치적으로 고찰하였다. 유한요소법에 의해 계산된 반사율은 수리모형실험을 통해 얻어진 결과와 비교하였을 때 비교적 잘 일치하였으며, 고유함수전개법에 의한 결과와도 좋은 일치를 나타내었다. 그밖에 본 연구에서 개발된 모형은 불투과성 수중방파제의 폭과 길이의 변화에 따른 반사율 계산에 적용되었다.

직립벽 앞에 놓인 일정깊이 잠긴 슬릿판에 의한 반사율 해석 (On an Analysis of Reflection Coefficients by a Partially Immersed Slotted Plate with a Back Wall)

  • 조일형
    • 한국해안해양공학회지
    • /
    • 제15권3호
    • /
    • pp.143-150
    • /
    • 2003
  • 고유함수전개법을 사용하여 수직벽 앞에 일정깊이 잠긴 슬릿판과 규칙파의 상호작용문제를 살펴보았다. 슬릿판에 의한 반사율에 영향을 미치는 주요 설계변수들은 공극율, 잠긴깊이, 챔버길이, 입사각도, 입사파의 주파수임을 확인하였다 슬릿판의 공극율이 0.1일 때 반사율이 전주파수에 걸쳐서 최소가 됨을 밝혔다. 반사율에 대한 해석결과와 Zhu(2001) 모형실험결과를 챔버길이와 잠긴깊이 그리고 입사파의 주기를 변화시키면서 비교한 결과, 두 결과는 서로 잘 일치하였다. 본 해석방법은 슬릿판 후면에서 발생한 박리에 의한 에너지 손실을 정확히 고려할 수 있으므로 슬릿 케이슨 방파제 제작에 필요한 설계정보를 제공할 것이다.

혼성방파제의 무공 및 유공 케이슨의 수리특성에 관한 실험 (An Experimental Investigation for Hydraulic Characteristics of Solid and Perforated-wall Caissons of a Mixed Type Breakwater)

  • 서경덕;오영민;전인식;이달수
    • 한국해안해양공학회지
    • /
    • 제4권4호
    • /
    • pp.243-249
    • /
    • 1992
  • 혼성방파제의 무공 및 유공 케이슨의 수리특성을 비교하기 위하여 파고 및 주기가 다른 여러 규칙파를 대상으로 수리실험을 실시하였다. 반사율, 전달률, 케이슨 전면에서의 쳐올림 높이 등 수리특성 면에서 모두 유공케이슨이 무공케이슨보다 유리한 것으로 나타났으며, 본 실험 결과가 기존의 이론식 또는 경험식들과 대체로 잘 일치함을 보였다. 특히, 유공케이슨의 반사율은 유수실 내에서의 공진현상과 밀접한 관계가 있어서 유수실의 폭이 유수실 내에서의 파장의 약 1/4 정도가 될 때 반사율이 최소가 됨을 알 수 있었다.

  • PDF