• Title/Summary/Keyword: Breakdown voltages

Search Result 248, Processing Time 0.028 seconds

Study on Thermal Stability Characteristics of Surge Arrester for High Power (전력용 피뢰기의 열안정화 특성)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1142-1145
    • /
    • 2004
  • ZnO surge arresters continuously endure the operating voltages during the operation course, and in the mean time, which need to withstand occasionally transient voltages of lightning and switching overvoltages. Under these voltages, the ZnO varistors inside arresters would have aging phenomena, one important result of aging phenomena is the increasing of resistive currents of varistors, which leads to the increasing of power losses of varistors. And the operating voltage is continuously applied on the ZnO varistors, there is a degradation phenomenon existing in ZnO varistors. When the degradation reaches a certain degree, then the arrester must stop operation. The degradation is related to the applied voltage ratio, the applied voltage ratio is high, the degradation is quickly. When the power loss is higher than the thermal dispersion ability of house of arrester, then the arrester will thermally breakdown. In this study the thermal stability characteristics of surge arresters for high power wil be discussed on the view point of watt losses and thermal breakdown.

  • PDF

Electrical Breakdown and Flashover Characteristics of Gaseous Helium at Cryogenic Temperature (극저온 헬륨가스의 절연파괴 및 연면방전 특성)

  • Kwag, Dong-Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.38-42
    • /
    • 2012
  • Fixtures such as bushings in terminations of high temperature superconducting(HTS) power cable systems are subjected to high voltages, which have to transition from ambient to cryogenic temperatures. As such it is imperative to ensure the integrity of the dielectrics under all operating conditions, including thermal aspects brought about by the passage of current. Gaseous helium(GHe) at high pressure is regarded as a potential coolant for superconducting cables. The dielectric aspects of cryogenic helium gas are both complex and demanding. In this experimental study we looked at the interface between a smooth epoxy surface and high pressure helium gas in a homogeneous electric field. The alternating current(AC) flashover voltages of epoxy samples are presented. The results have been analyzed by using Weibull statistics. In addition to the behavior of the epoxy in gaseous helium as a function of pressure and temperature we also present data of the characteristics of the epoxy in mineral oil and in liquid nitrogen($LN_2$). The breakdown characteristics of a uniform field gap in gaseous helium as a function of pressure and temperature under AC, direct current(DC) and lightning impulse voltages are also given. Electric field calculations have been made for one of the experimental geometries in an attempt to explain some of the anomalies in the experimental results.

Electrical Characteristics of Insulation Paper for Distribution Transformers (배전변압기용 절연지의 전기적 특성)

  • Jung, J.W.;Song, I.K.;Lee, B.S.;Han, J.H.;Kweon, D.J.;Kim, C.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.1-5
    • /
    • 2001
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material of distribution transformers. The relative permittivities(dielectric constants) and $tan{\delta}$(dielectric dissipation factors) were measured as a dielectric characteristic and the partial discharge inception voltages(PDIVs) and breakdown voltages were also measured as an electrical strength characteristic of Nomex paper. As a result, the permittivity and $tan{\delta}$ of Nomex paper showed temperature and frequency dependency. Especially, the permittivity of 0.18mm Nomex paper was 2.4 according to the ASTM condition. And the PDIVs and breakdown voltages were, almost linearly increased with the thickness of Nomex paper and its electrical strength was better than conventional kraft paper.

  • PDF

Two Factors Failure Model of Oil-Paper Insulation Aging under Electrical and Thermal Multistress

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.957-963
    • /
    • 2014
  • Converter transformers play important roles in high-voltage direct current transmission systems. This paper presents experimental and analysis results of the combined electrical and thermal aging of oil-impregnated paper at pulsating DC voltages. Breakdown voltages and time-to-breakdown of oil-paper specimens were measured by using short-time and constant-stress tests. The breakdown characteristics of combined electrical and thermal aging on insulation system were discussed. According to the relationship between failure time and aging temperature, the two-parameter Weibull model was improved. On the basis of the competing risk algorithm and the improved Weibull model, the two factors failure model was calculated. And the influence of temperature in the insulation system has been analyzed. This model performs better than the two-parameter Weibull model when both time and temperature are considered as variables in estimating the lifetime of oil-paper insulation.

Influence of Combustion Flame on Breakdown Characteristics of Vertical-Model Power Lines (수직배열 모델 전력선의 절연파괴 특성에 미치는 화염의 영향)

  • Park, Kwang-Seo;Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.85-92
    • /
    • 2008
  • Occurring forest fire or burning bushes beneath overhead transmission lines have caused breakdown disturbances of the system in many countries. In this study, experiments for flashover characteristics in the simulated condition of vertical power lines were conducted so as to investigate the reduction in insulation strength caused by combustion flame. As the results of an experimental investigation, it is demonstrated that flame can reduce breakdown voltages of the model lines according to height(h) of flame. The breakdown voltages were decreased with decreasing the height(h) of flame it can be seen that the average reduction of flashover levels, in comparison with the no-flame case, are 46.2[%] for h=9[cm] and 62.5[%] for h=3[cm] when ac voltage is applied.

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

A Study on the Measurements of Parameters Affecting the Breakdown Mechanism of a Large Air Spacing (이격거리가 큰 전극의 공기 절연파괴에 영향을 미치는 인자측정에 관한연구)

  • Cho, Yun-Ok;Choi, Young-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.756-760
    • /
    • 1988
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/${\mu}s$ - 5cm/${\mu}s$, electric field intensity of 2kv/cm, predischarge current of 1.2A - 1.6A, the charges injected into the air gap of 11 - 40 ${\mu}$C for 400-887kV impulse voltages.

  • PDF

A Study on the Measurements of Discharge Parameters in Case of the Switching Impulse Breakdown of a Large Air Spacing (이격거리가 큰 전국의 공기절연파괴 현상시 발생하는 인자측정에 관한 연구)

  • 최영욱;조연옥
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1290-1295
    • /
    • 1991
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/x10S0-6Ts - 5cm/x10S0-6Ts, electric field intensity of 2kv/cm, predischarge current of 1.2-1.6A, the charges injected into the air gap of 11-40x10S0-6TC for 400-887kV impulse voltages.

  • PDF

Approximate Equations and sensitivity for Breakdown Voltages of Cylindrical PN Junctions (원통형 PN 접합의 항복전압에 대한 근사식과 민감도)

  • Yun, Jun-Ho;Kim, Hae-Mi;Choi, Yearn-Ik;Jo, Jung-Yol
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.179-180
    • /
    • 2008
  • Approximate equations for cylindrical breakdown voltages of planar pn junctions are proposed and verified. The equations show good agreement with the Baliga's results for rj/Wpp${\leq}0.3$ and with numerical results for rj/Wpp${\geq}0.3$ within 1 % error. Sensitivity of the breakdown voltage with respect to the doping concentrations is successfully derived using the approximate equations. The sensitivity formula can be utilized in the area of tolerance design of power semiconductor devices.

  • PDF

The effect of particle on insulation Characteristic of $SF_6-N_2$ Mixtures ($SF_6-N_2$ 혼합가스의 절연특성에 미치는 파티클의 영향)

  • Lee, Kon;Lee, Dong-Zoon;Lee, Kang-Soo;Kim, Kyung-Wha;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2383-2385
    • /
    • 1999
  • This paper describes the effect of particles on insulation characteristics of $SF_6-N_2$ mixtures such as breakdown voltages, lift-off voltages and maximum discharge. As a result, the breakdown voltage was increased with the increment of $SF_6$ and the mixture containing 20[%] of $SF_6$ has a breakdown voltage ratio factor better than the other mixtures. The lift-off voltage was nearly constant with all mixtures. Discharge was decreased with the increment of $SF_6$.

  • PDF