• Title/Summary/Keyword: Breakdown test

Search Result 474, Processing Time 0.022 seconds

A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications (진단용 X선장치의 성능 실태 조사연구)

  • Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

Development of Automation Software for Corner Radius Analysis of Composite Laminated Structure (복합재 적층 구조물의 코너 부 파손 해석을 위한 자동화 소프트웨어 개발)

  • Hyeon, Ju-Ha;Moon, Yong-Ho;Ha, Seok-Wun
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.3
    • /
    • pp.107-114
    • /
    • 2018
  • Recently, as aviation industry has been activated, development of software related to composite materials has been demanded. Composite analysis requires specialized structural analysis and test evaluation. Therefore, it is necessary to use existing commercial software to analyze the composite structure, but existing commercial software only provides limited functions. Especially, since there is no specialized software for corner structure analysis of aerospace composites spa structure, much human resources and time are consumed in structural analysis. In order to solve this problem, we developed a GUI-based automation software based on user-friendly GUI that reflects the existing corner structure analysis procedure and provides multiple breakdown criteria. To verify the reliability of the structural analysis results of the developed software, it was confirmed that there is no problem in the structural analysis performance as a result of comparing with the existing analysis results.

A Study on Performance Analysis of a Fish Cage using Air Chamber Structure (대형공기구조물을 이용한 가두리양식장의 성능해석)

  • Choi, Jin;Kim, Soo-Young;Kim, Duk-Eun;Jeong, Seong-Jae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.1 s.145
    • /
    • pp.119-127
    • /
    • 2006
  • Recently as a result of excessive development. pollution of the coast and occurrence of a typhoon year after year, fishermen suffer heavy losses in fish farming which is the one of the most important earnings ways. For solution of these problems, we need to go out into the open sea from an inland sea. In this study we suggested new fish cage which makes up for the structural weakness of existing wooden fish cages. It can farm fishes in the open sea of high wave and current with no damages from a typhoon. We substituted TPU(Thermoplastic Polyurethane) air chamber for existing styrofoam flotage which was harmful to the environment and impermanent. We used PE(Polyethylene) pipes for the maintenance of formation and the prevention of buoyancy loss caused by a breakdown of flotage. PE b rackets were designed to combine PE pipes with TPU air-chamber flotage. It has good strength and light weight. As a result of modeling test. it is great in buoyancy, strength and flexibility against wave. Because it can control buoyancy arbitrarily, moreover, we expect that it will reduce damages of a red water by applying it as semi-submerged fish cages.

Properties of double-layered anodizing films on Al alloys formed by two consecutive anodizings (알루미늄 합금의 연속식 양극산화법으로 형성시킨 이중 산화막층의 특성)

  • Jeong, Nagyeom;Choi, Jinsub
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.1
    • /
    • pp.30-36
    • /
    • 2021
  • In this study, double-layered anodizing films were formed on Al 5052 and Al 6061 alloys consecutively first in sulfuric acid and then in oxalic acid, and hardness, withstand voltage, surface roughness and acid resistance of the anodizing films were compared with single-layered anodizing films in sulfuric acid and oxalic acid electrolytes. Hardness of the double-layered anodizing film decreased with increasing ratio of inner layer to outer layer for both Al 5052 and Al 6061 alloys, suggesting that outer anodizing film formed in sulfuric acid electrolyte is damaged during the second anodizing in oxalic acid electrolyte. Withstand voltage of the double-layered anodizing films increased with increasing the thickness ratio of inner layer to outer layer. Surface roughness of the double-layered anodizing films were comparable with that of single-layered anodizing film formed in sulfuric acid but higher than that of single layer anodizing film formed in oxalic acid electrolyte. In acid resistance test, all of the double-layered and single-layered anodizing films showed good acid resistance more than 3 h without any visible gas evolution, which is attributable to sealing of pores. Based on the experimental results obtained in this work, it is possible to design a double-layered anodizing film with cost-effectiveness and improved physical and electrical properties by combining two consecutive anodizing processes of sulfuric acid anodizing and oxalic acid anodizing methods.

A Study on LSTM-based water level prediction model and suitability evaluation (LSTM 기반 배수지 수위 변화 예측모델과 적합성 평가 연구)

  • Lee, Eunji;Park, Hyungwook;Kim, Eunju
    • Smart Media Journal
    • /
    • v.11 no.5
    • /
    • pp.56-62
    • /
    • 2022
  • Water reservoir is defined as a storage space to hold and supply filtered water and it's significantly important to manage water level in the water reservoir so as to stabilize water supply by controlling water supply depending on demand. Liquid level sensors have been installed in the water reservoir and the pumps in the booster station facilitated management for optimum water level in the water reservoir. But the incident responses including sensor malfunction and communication breakdown actually count on manager's inspection, which involves risk of accidents. To stabilize draining facility management, this study has come up with AI model that predicts changes in the water level in the water reservoir. Going through simulation in the case of missing data in the water level to verify stability in relation to the field application of the prediction model for water level changes in the reservoir, the comparison of actual change value and predicted value allows to test utility of the model.

Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure (분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측)

  • Lee, Sanguk;Kim, Jungho Justin;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

Insulation tests of Continuously Transposed Coated Conductors for a high voltage superconducting transformer (초고압 초전도 변압기용 고온 초전도 연속전위도체의 절연특성)

  • Kim, Y.;Kim, W.S.;Park, S.H.;Park, C.;Lee, S.;Cheon, H.G.;Kim, S.H.;Lee, J.K.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.21-24
    • /
    • 2010
  • A cryogenic insulation technique for a high voltage and a large current capacity of a conductor are now two big issues in a field of recent R&D projects of superconducting power devices, especially a superconducting power transformer. For the large rated currents of the power transformer, it is well known that lots of 2nd generation superconducting conductor, so called coated conductor, should be stacked together with transpositions in order to get an even distributions of the currents. We had come up with an idea of a CTCC (Continuously Transposed Coated Conductor) as a conductor for a large power superconducting transformer, and keep trying to verify the usefulness of the conductor. As one of the efforts of verifying, we prepared and tested a sample CTCC with insulations for high voltage, which includes the epoxy coating and Nomex$^{(R)}$ wrapping. This paper contains the insulation process and dielectric breakdown test results. We expect the results obtained from this experiment to improve an insulation technique for high voltages in various cryogenic environments[1,2].

Analysis of Levelized Cost of Electricity for Type of Stationary Fuel Cells (발전용 연료전지 형식에 따른 균등화 발전비용 분석)

  • DONGKEUN LEE;TORRES PINEDA ISRAEL;YONGGYUN BAE;YOUNGSANG KIM;KOOKYOUNG AHN;SUNYOUP LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.643-659
    • /
    • 2022
  • For the economic analysis of fuel cells, levelized cost of electricity was calculated according to the type, capacity, and annual production of the fuel cells. The cost of every component was calculated through the system component breakdown. The direct cost of the system included stack cost, component cost, assembly, test, and conditioning cost, and profit markup cost were added. The effect of capacity and annual production was analyzed by fuel cell type. Sensitivity analysis was performed according to stack life, capital cost, project period, and fuel cost. As a result, it was derived how much the economic efficiency of the fuel cell improves as the capacity increases and the annual production increases.

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

Studies on the Manufacture of Fiber Pot and its Effect for the Good Transplanting (이식용(移植用)Pot의 제조(製造) 및 그 효과(効果)에 관(關)한 연구(硏究))

  • Kim, Ji Moon;Lee, Hwa Hyung;Kwon, Ki Won;Song, Ho Kyong
    • Journal of Korean Society of Forest Science
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 1980
  • This study was carried out to examine the substitution possibility into fiber pot instead of Jiffy pot for the good transplanting. Fiber pot was made of fiber, wood waste particle, and bark powder (10% of the particle weight) and also latex was added into the furnish as a binder. The pots were sprayed with just enough urea solution to prevent nitrogen deficiency of pot media coming from the breakdown of wood fiber in the pot wan during the plant growing. The utility of fiber pot was compared with that of Jiffy pot in the service test of two tree species under a green-house condition. The results obtained can be summarized as follows ; 1. Fiber pot made of 30% wood fiber+70% particle including 10% of bark powder, and 3%-latex has shown a good results like that of Jiffy pot in the sp. gr., tear factor and burst factor. For water absorption, fiber pot made of 50% fiber+50% particle, and 3%-latex got the best result. In the consideration of the above physical and mechanical properties of the fiber pot for good root penetration through the pot wall and facile handling, fiber pot made of 30% fiber+70% particle, and 3%-latex may be seemed to be good. 2. There were no harms in sapling growth in fiber pot as well as in Jiffy pot. The root penetration ability through the fiber pot was slightly inferior to that of Jiffy pot, and yet the pot damage through transportation seemed to be slighter in fiber pot than in Jiffy pot.

  • PDF