• Title/Summary/Keyword: Breakdown location

Search Result 56, Processing Time 0.03 seconds

Indirect Fault Detection Method for an Onboard Degaussing Coil System Exploiting Underwater Magnetic Signals

  • Jeung, Giwoo;Choi, Nak-Sun;Yang, Chang-Seob;Chung, Hyun-Ju;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.72-77
    • /
    • 2014
  • This paper proposes an indirect fault detection method for an onboard degaussing coil system, installed to reduce the underwater magnetic field from the ferromagnetic hull. The method utilizes underwater field signals measured at specific magnetic treatment facilities instead of using time-consuming numerical field solutions in a three-dimensional space. An equivalent magnetic charge model combined with a material sensitivity formula is adopted to predict fault coil locations. The purpose of the proposed method is to yield reliable data on the location and type of a coil breakdown even without information on individual degaussing coils, such as dimension, location and number of turns. Under several fault conditions, the method is tested with a model ship equipped with 20 degaussing coils.

Effectiveness Evaluation According to Change of IJ Joint Box Location and Grounding System in Underground Transmission System (지중송전계통에서 절연접속함 위치 및 접지방식 변경의 효용성 평가)

  • Ko, Kwang-Man;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Dielectric breakdown accidents have been mainly occurred in the vicinity of service entrance section in underground power transmission systems. One cause among them is due to the excessive component value of sheath located around service entrance of cable. In this paper, as one of the alternative to prevent these accidents, the change of cross bond grounding system and the location change of IJ(Insulation Joint) are suggested. Also, to evaluate effectiveness of this changing system, circulating current and induced voltage of sheath were analyzed in steady and transient state. By comparison of the analytical results for the several possible changing systems, a grounding system and location of IJ which has the smallest sheath component values is proposed. In this paper, analysis to evaluate the proposed system is carried out by EMTP/ATPDraw. It can be used as a valuable operational material to prevent accident of the service entrance section in underground power transmission system.

A Study on Composition of Position Detection System using GPS (GPS 위치검지시스템 구성에 관한 연구)

  • Han, Young-Jae;Park, Choon-Soo;Lee, Tae-Hyoung;Kim, Ki-Hwan;Eun, Jong-Phil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.151-155
    • /
    • 2008
  • KHST(Korean High Speed Train) has been utilized the total measurement system which evaluates the efficiency and a breakdown of the vehicle and it's results effect to secure reliability of the vehicle. Generally KHST has been received pulse signals from the wheel. It calculates the travel distance after counter the signals to confirm location information of the vehicle. However, there is a limit to measure the location of the vehicle due to slip, slide and the wheel attrition. We have developed a new measurement system by using GPS to complement those errors. In general, GPS receivers are composed of an antenna, tuned to the frequencies transmitted by the satellites, receiver-processors, and a highly-stable clock The GPS mounted on the roof of TT4 in KHST receives a signal from the RS232 communication port. It is connected to the network system in TT3 after converting with TCPIP communication. It is able to track the position of vehicle and synchronize the signal from different measurement system simultaneously. Therefore it is able to chase the fault occurrence, track inspection and electrical interruption at real-time situation more accurately. There is not an error coursed by vehicle conditions such as slip and the slide.

e-Learning Education System on Web

  • Choi, Sung;Han, Jung-Lan;Chung, Ji-Moon
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.283-294
    • /
    • 2004
  • Within the rapidly changing environment of global economics, the environment of higher education in the universities & companies, also, has been, encountering various changes. Popularization on higher education related to lifetime education system, putting emphasis on the productivity of education services and the acquisition of competitiveness through the market of open education, the breakdown of the ivory tower and the Multiversitization of universities & companies, importance of obtaining information in the universities & companies, and cooperation between domestic and oversea universities, industry and educational system must be acquired. Therefore, in order to adequately cope with these kinds of rapid changes in the education environment, operating E-Learning Education & company by utilizing various information technologies and its fixations such as Internet, E-mail. CD-ROMs. Interactive Video Networks (Video Conferencing, Video on Demand), CableTV etc., which has no time or location limitation, is needed.

  • PDF

A Study on Carrier Injection and Trapping by the High Field for MAS (Al-Al2O3-Si(n)) Structure ($Al-Al_2O_3-Si$(N형)의 MAS 구조에 있어서 고전계에 의한 Carrier 주인과 트?에 관한 연구)

  • 이영희;박성희
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.10
    • /
    • pp.465-472
    • /
    • 1986
  • The present study was carried out to investigate the mechanism which control the voltage instability and the breakdown of CVD Al2O3 on Si substrates. Our sample were metal-Al2O3-Oi Capacitors with both Al and Au field plates. Electron injection and trapping, with resultant positive flatband voltage shift, occur at fields as low as 1-2[MV/cm.] We developed an approximate method for computing the location of the centroid of the trapped electrons. Our results indicate that the electrons are trapped near the injecting interface, at least for fields less than about 5[MV/cm ] Because of continued charging, a true steady state is probably never reached, and the only unique I-V curve is the one obtained initially, when the traps are empty. We measured this I-V curve for both polarities of applied voltage, using a fresh sample for each point. The observed current densities are much larger than those obtained in thermally grawn SiO2.

  • PDF

User Authentication Risk and Countermeasure in Intelligent Vehicles (지능형 자동차의 사용자 인증에 대한 위협 및 대응 기법)

  • Kim, Seung-Hwan;Lee, Keun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.1
    • /
    • pp.7-11
    • /
    • 2012
  • Intellgent Vehles network capabilities can cause a lots of security issues such as data hacking, privacy violation, location tracking and so on. Some possibilities which raise a breakdown or accident by hacking vehicle operation data are on the increase. In this paper, we propose a security module which has user authentication and encryption functionalities and can be used for vehicle network system.

Analysis of Voltage Stability in Electric Railway Feeding System (전기철도 급전계통의 집전전압 안정도 해석)

  • Lee Chang-Mu;Lee Han-Min;Han Moon-Seob;Kim Joo-Rak;Jung Ho-Seong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1384-1389
    • /
    • 2004
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to the length of feeding line, load, location and power factor of electric locomotive. And through case study, compare measurement result and simulation result

  • PDF

Cost-effective structural health monitoring of FRPC parts for automotive applications

  • Mitschang, P.;Molnar, P.;Ogale, A.;Ishii, M.
    • Advanced Composite Materials
    • /
    • v.16 no.2
    • /
    • pp.135-149
    • /
    • 2007
  • In the automobile industry, structural health monitoring of fiber reinforced polymer composite parts is a widespread need for maintenance before breakdown of the functional elements or a complete vehicle. High performance sensors are generally used in many of the structural health monitoring operations. Within this study, a carbon fiber sewing thread has been used as a low cost laminate failure sensing element. The experimentation plan was set up according to the electrical conductance and flexibility of carbon fiber threads, advantages of preforming operations, and sewing mechanisms. The influence of the single thread damages by changing the electrical resistance and monitoring the impact location by using carbon thread sensors has been performed. Innovative utilization of relatively cost-effective carbon threads for monitoring the delamination of metallic inserts from the basic composite laminate structure is a highlighting feature of this study.

Estimation of the Feeding Line Capacity according to Feeding Mehtod (급전방식에 따른 급전선로의 전송용량 예측)

  • Lee, Chang-Mu;Lee, Han-Min;Oh, Se-Chan;Kim, Gil-Dong;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1169-1170
    • /
    • 2007
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway according to the type of feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to feeding method, load, location and power factor of electric locomotive.

  • PDF

A Study on the Aging Characteristics and Life Diagnosis of Insulating Materials for Power Cable (전력케이블용 절연재료의 열화특성 및 수명진단에 관한 연구)

  • 박홍태;김경석;남창우;이규철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.12 no.1
    • /
    • pp.11-17
    • /
    • 1999
  • Aging characteristics of the crosslinked polyethylene have been measured after applying electrical, thermal and combined stresses. ICP and FT-IR measurements confirmed diffusion of low molecular weight components such as antioxidant and presence of carbonyl group. Carbonyl group of aged crosslinked polyethylene under combined stress was detected by FT-IR. As deterioration of the crosslinked polyethylene progresses, crystallinity degree and density decrease. Also, dielectric properties have been measured by tan $\delta$ and $\varepsilon$$_{r}$ measurements. The three-parameter Weibull distribution was found to be the best suited among other probabilistic distribution representing the dielectric breakdown strength of aged crosslinked polyethylene. The scale parameter and location parameter decreases as the applied stress increases. The shape parameter increases as the stress increases.s.

  • PDF