Insulation Characteristics of High Temperature Superconducting Cable (고온 초전도 레이블의 절연 특성)

  • Kim, H.J.;Kim, J.H.;Sim, K.D.;Kim, H.J.;Cho, J.W.;Seong, K.C.;Kwag, D.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF

Two Factors Failure Model of Oil-Paper Insulation Aging under Electrical and Thermal Multistress

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.957-963
    • /
    • 2014
  • Converter transformers play important roles in high-voltage direct current transmission systems. This paper presents experimental and analysis results of the combined electrical and thermal aging of oil-impregnated paper at pulsating DC voltages. Breakdown voltages and time-to-breakdown of oil-paper specimens were measured by using short-time and constant-stress tests. The breakdown characteristics of combined electrical and thermal aging on insulation system were discussed. According to the relationship between failure time and aging temperature, the two-parameter Weibull model was improved. On the basis of the competing risk algorithm and the improved Weibull model, the two factors failure model was calculated. And the influence of temperature in the insulation system has been analyzed. This model performs better than the two-parameter Weibull model when both time and temperature are considered as variables in estimating the lifetime of oil-paper insulation.

Analysis of Insulation Aging in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 절연열화 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Young-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.200-203
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in eight high voltage motors. Diagnostic tests included polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 motor failed near rated voltage of 12.96 kV. The breakdown voltage of No. 4 motor was 6.99 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

  • PDF

A Life Prediction of Insulation Degradation Using Complex Sensing System (복합 감지 시스템을 이용한 부분방전의 절연열화 수명추정)

  • Kim, S.H.;Kim, J.H.;Park, J.J.;Choi, J.K.;Yoon, H.J.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.348-350
    • /
    • 1997
  • Because of internal voids ininsulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation. We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. Finally using statically operator such as the center of gravity(G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

Breakdown, V-t and Degradation Characteristics of Insulation in Liquid Nitrogen for HTS Transformer (고온초전도 변압기를 위한 액체질소 중 절연 파괴, V-t. 열화 특성)

  • Nguyen, Van-Dung;Joung, Jong-Man;Baek, Seung-Myeong;Lee, Chang-Hwa;Suck, Song-Hee;Kim, Sang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • HTS transformer is one of the most promising devices to supply enough electric energy for quick increase consumption. However, for practical design of the HTS transformer, it is necessary to establish the research on breakdown, V-t characteristics, degradation, and so on. In this paper, we discussed breakdown characteristics and V-t characteristics of polyimide/L$N_2$ and glass fiber reinforced plastic/$LN_2$ composite insulations. These composite insulations have been used as turn-to-turn and layer-to-layer insulations for HTS transformer respectively, Moreover, we investigated the degradation of these insulation samples after breakdown using microscope and SEM photograph.

The analysis & comparative method on the breakdown voltage in $SF_6$ ($SF_6$ 상태에 따른 절연파괴전압 비교분석에 관한 연구)

  • Choi, Eun-Hyuck;Yoon, Dae-Hee;Park, Kwang-Soo;Park, Won-Goo;Joo, Jae-Hyun;Choi, Sang-Tae;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.335-338
    • /
    • 2004
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and insulation characteristics about liquid $SF_6$ in GIS(Gas Insulated Switchgear) were described. From this result, at low temperature, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble when high voltage apply to electrode. Corona was happened to weak bubble and was proceed to new bubble breakdown.

  • PDF

Electrical Properties for Micro-and-Nano- Mixture Composites using Electric Field Dispersion (전기장분산법을 이용한 나노와 마이크로 혼합된 콤포지트의 전기적 특성)

  • Cho, Dae-Lyoung;Kim, Jong-Ho;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.32-32
    • /
    • 2010
  • A epoxy/multilayered silicate nanocomposite was prepared by a new AC electric application method and micro silica particle was poured into the nanocomposite in order to prepare epoxy/micro-and-nano- mixed composites (EMNC). Electric insulation breakdown strength was measured in a sphere-sphere electrode system designed for the prevention of edge breakdown and the data were estimated by Weibull plot. As the exfoliated silicate nano-plates were homogeniously dispersed in the micro silica particles, the insulation property was higherd.

  • PDF

A Study of PBD and BD Voltage Characteristics in the Simulate Electrode System of Solenoid Type High Temperature Superconducting Coils (솔레노이드형 고온초전도코일 모의전극계에서 부분 및 완전파괴전압특성 연구)

  • 석복렬
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.94-98
    • /
    • 2002
  • The Partial breakdown (PBD) and complete breakdown (BD) voltage characteristics in a composite insulation system of glass fiber reinforced plastics (GFRP) and liquid nitrogen are investigated to find the PBB and BD characteristics in solenoid type high temperature superconducting (HTS) coils at quench. The electrode system used is made from a coaxial spiral coil-to-cylindrical electrode with an insulation barrier and spacers, and is immersed in liquid nitrogen. A heater is mounted inside the coil electrode to generate boiling which occurs on quenched superconducting coils. The experimental results show that: (1) breakdown voltages are affected severely by the risetime of the applied voltage and the PBD inception voltage, (2) two kinds of BD mechanisms are found depending on the shape of the spacer, length of cooling channel and heater power.

Breakdown Properties for Insulation Design of the Environment-Friendly Pole Transformer using the Vegetable Insulating Oil (식물성절연유를 사용한 친환경 주상변압기 설계를 위한 절연파괴 특성)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.7-12
    • /
    • 2011
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The newly invented vegetable insulating oil is highly biodegradable and have negligible impact on the environment, human health and the ecosystem. For development of the environmental-friendly pole transformer using vegetable insulating oil, the dielectric constructions of the pole transformer were discussed in this paper. Depending on the dielectric constructions, the AC breakdown characteristics of the Nomex insulating papers and the vegetable insulating oil were studied by simulated electrode systems. Based on the experimental results, the maximum design stress($E_{max}$) for insulation design of the environmental-friendly pole transformer were suggested.

Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field (불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF