• Title/Summary/Keyword: Bragg 피크

Search Result 37, Processing Time 0.021 seconds

The characteristics of tilted grating in depressed- and step- index fiber and its application (Depressed index type과 Step index type 광섬유에서의 경사진 브래그격자 특성과 응용)

  • 권서원;이상배;최상삼;박진우
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.83-91
    • /
    • 1998
  • Fiber Bragg grating which has a blazed ang1e to the plane of incident wave generates a side-mode as well as main-mode. The side-mode has an identical characteristics with a long period grating that couples with a cladding mode, so rejects the special wavelength. We experimented on the side-mode characteristics with two fibers which Ge doped depressed index fiber and very high photosensitive H$_2$ loaded step index fiber according to the tilted angle. Also, using a phase mask equipped with rotation plate which has 0.02$^{\circ}$ resolution, we can control the bandwidth and the peak value of a total loss spectrum by aligned tilted grating in a fiber and using this, tried to compose the ASE band rejection filter of the Erbium doped fiber amplifier.

  • PDF

Dose Distribution of 100 MeV Proton Beams in KOMAC by using Liquid Organic Scintillator (액체 섬광체를 이용한 100 MeV 양성자 빔의 선량 분포 평가)

  • Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.621-626
    • /
    • 2017
  • In this paper, an optical dosimetric system for radiation dose measurement is developed and characterized for 100 MeV proton beams in KOMAC(Korea Multi-Purpose Accelerator Complex). The system consists of 10 wt% Ultima GoldTM liquid organic scintillator in the ethanol, a camera lens(50 mm / f1.8), and a high sensitivity CMOS(complementary metal-oxide-semiconductor) camera (ASI120MM, ZWO Co.). The FOV(field of view) of the system is designed to be 150 mm at a distance of 2 m. This system showed sufficient linearity in the range of 1~40 Gy for the 100 MeV proton beams in KOMAC. We also successfully got the percentage depth dose and the isodose curves of the 100 MeV proton beams from the captured images. Because the solvent is not a human tissue equivalent material, we can not directly measure the absorbed dose of the human body. Through this study, we have established the optical dosimetric procedure and propose a new volume dose assessment method.

The Defect Characterization of Luminescence Thin Film by the Positron Annihilation Spectroscopy (양전자 소멸 측정을 이용한 발광 박막 구조 결함 특성)

  • Lee, Kwon Hee;Bae, Suk Hwan;Lee, Chong Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.250-256
    • /
    • 2013
  • It is described that the proton beam induces micro-size defects and electronic deep levels in luminescence Thin Film. Coincidence Doppler Broadening Positron Annihilation Spectroscopy (CDBPAS) and Positron lifetime Spectroscopy were applied to study of characteristics of a poly crystal samples. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S-parameter value. The samples were exposed by 3.0 MeV proton beams with the intensities ranging between 0 to ${\sim}10^{14}$ particles. The S-parameter values decreased as increased the proton beam, that indicates the protons trapped in vacancies. Lifetime ${\tau}_1$ shows that positrons are trapped in mono vacancies. Lifetime ${\tau}_2$ is not changed according to proton irradiation that indicate the cluster vacancies of the grain structure.

PECVD와 고상결정화 방법을 이용한 poly-SiGe 박막의 제조

  • 이정근;이재진
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.55.2-55
    • /
    • 1998
  • 다견정 심리판-거l르마늄(JXlly-SiGe)은 TFT(thin-film transistor)와 갇븐 소자 응용에 있어서 중요한 불칠이다 .. LPCVD (low pressure chemical vapor deposition) 방법으로 비정칠 SiGc (a-SiGe) 박막올 증 착시키고 고상결정화(SPC: solid-phase crystallization)시켜 poly-SiGc옹 얻는 것은 잘 알려져 있다. 그러 나 그러나 PF'||'&'||'pound;VD-SPC 방법올 이용한 poly-SiGc의 제조에 대해서는 아직 두드러지게 연구된 바 없다. 우리단 PF'||'&'||'pound;VD 방법으로 a-SiGc 박막올 증착시키고 고상캘정화시켜 poly-SiGc올 얻었 R며, :~ 결정성, G Gc 농도, 결정핍의 평끌 크기 눔올 XRD (x-ray diffraction) 방법으호 조사하였다. 특히 pr'||'&'||'pound;VD 증착시 가판온도,Gc 함유량 등이 고상화에 미치는 영향에 대해서 조사하였다. P PECVD 장치는 터보펌프콸 사용하여 71저진공이 2xlOlongleftarrow5 Torr에 이르렀다. 가판윤 SiOOO) 웨이퍼륜 사용하고 기판 온도는 약 150- 35()"C 사이에서 변화되었다. 증착가스는 SiH4, GcH4, 112 등흘 썼다. 증착 압력과 r.f 전력용 각각 O.25ToIT와 3W로 일정하게 하였다 .. Gc 함유량(x)은 x x=O.O-O.5 사이에서 변화되었다 .. PECVD모 증착된 SiGc 박막들은 고상결정화를 위해 $\theta$X)"(:: Nz 분위기에서 24시간동안, 혹은 5OO'C에서 4열간 가열되었다. 고상결정화 후 poly-SiGc 박막은 SiGc(Ill), (220), (311) XRD 피크들올 보여주었으며, 각 피 크들은 poly-Si에 비하여 왼쪽으로 Bragg 각이 이동되었고, Vegard’slaw에 의해서 x의 값올 확 인할 수 있었다. 이것온 RBS 결과와 열치하였다. 약 150-350'C 사이에서 변화된 기판온도의 범위 에서 증착온도가 낮올수콕 견정립의 크기는 대체로 증가하는 것으로 나타났다 .. XHD로 추정된 형 균 결정립의 크기는 최대 약 3$\alpha$1m 정도였다. 또한 같끈 샘플뜰에 대해서 기판온도가 낮올수록 증착속도가 증가함옴 확인하였다 .. Gc 함유량이 x=O.1에서 x=O.5로 증가함에 따라서도 결정립의 크기와 SiGc 증착속도는 증가하는 것으로 나타났다 .. Hwang [1] , Kim[2] 둥의 연구자들은 Gc 함유 량이 증가함에 따라 결정 립 크기가 캄소하는 것올 보고하였으냐, Tsai [3] 둥은 반대의 결과플 보 고하고 Ge 힘유량의 증가시 결정립 크기의 증가에 대해 Gc의 Si보다 낮은 융점 (melting point) 올 강조한 바 있다. 결정립 크기의 증가는 대체로 SiGe 중착속도의 증가와도 관련이 있음올 볼 때, poly-SiGc의 경우에도 polv-Si의 고상화에서와 같이 증착속도가 빠를수록 최종적언 결정럽의 크기가 커지는 것으로 이해될 수도 있다 .. PECVD 증착시 증착속도의 증가는 증착된 박딱에서의 무켈서도를 증 가시킬 수 있음올 고려하면, 이라한 결파플온 p이y-SiGc의 고상결정화에서도 ploy-Si의 고상결정 화에서와 마찬가지로 초기 박막에서의 구조직 무절서도가 클수록, 고상결정화 후 결정 립의 크기 가 커칠 수 있음올 보여준다고 생각휠 수 있다,

  • PDF

Comparative Evaluation of Radioactive Isotope in Concrete by Heavy Ion Particle using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가)

  • Bae, Sang-Il;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.359-365
    • /
    • 2021
  • A heavy particle accelerator is a device that accelerates particles using high energy and is used in various fields such as medical and industrial fields as well as research. However, secondary neutrons and particle fragments are generated by the high-energy particle beam, and among them, the neutrons do not have an electric charge and directly interact with the nucleus to cause radiation of the material. Quantitative evaluation of the radioactive material produced in this way is necessary, but there are many difficulties in actual measurement during or after operation. Therefore, this study compared and evaluated the generated radioactive material in the concrete shield for protons and carbon ions of specific energy by using the simulation code FLUKA. For the evaluation of each energy of proton beam and carbon ion, the reliability of the source term was secured within 2% of the relative error with the data of the NASA Space Radiation Laboratory(NSRL), which is an internationally standardized data. In the evaluation, carbon ions exhibited higher neutron flux than protons. Afterwards, in the evaluation of radioactive materials under actual operating conditions for disposal, a large amount of short-lived beta-decay nuclides occurred immediately after the operation was terminated, and in the case of protons with a high beam speed, more radioactive products were generated than carbon ions. At this time, radionuclides of 44Sc, 3H and 22Na were observed at a high rate. In addition, as the cooling time elapsed, the ratio of long-lived nuclides increased. For nonparticulate radionuclides, 3H, 22Na, and for particulate radionuclides, 44Ti, 55Fe, 60Co, 152Eu, and 154Eu nuclides showed a high ratio. In this study, it is judged that it is possible to use the particle accelerator as basic data for facility maintenance, repair and dismantling through the prediction of radioactive materials in concrete according to the cooling time after operation and termination of operation.

Evaluation of Antenna Pattern Measurement of HF Radar using Drone (드론을 활용한 고주파 레이다의 안테나 패턴 측정(APM) 가능성 검토)

  • Dawoon Jung;Jae Yeob Kim;Kyu-Min Song
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.109-120
    • /
    • 2023
  • The High-Frequency Radar (HFR) is an equipment designed to measure real-time surface ocean currents in broad maritime areas.It emits radio waves at a specific frequency (HF) towards the sea surface and analyzes the backscattered waves to measure surface current vectors (Crombie, 1955; Barrick, 1972).The Seasonde HF Radar from Codar, utilized in this study, determines the speed and location of radial currents by analyzing the Bragg peak intensity of transmitted and received waves from an omnidirectional antenna and employing the Multiple Signal Classification (MUSIC) algorithm. The generated currents are initially considered ideal patterns without taking into account the characteristics of the observed electromagnetic wave propagation environment. To correct this, Antenna Pattern Measurement (APM) is performed, measuring the strength of signals at various positions received by the antenna and calculating the corrected measured vector to radial currents.The APM principle involves modifying the position and phase information of the currents based on the measured signal strength at each location. Typically, experiments are conducted by installing an antenna on a ship (Kim et al., 2022). However, using a ship introduces various environmental constraints, such as weather conditions and maritime situations. To reduce dependence on maritime conditions and enhance economic efficiency, this study explores the possibility of using unmanned aerial vehicles (drones) for APM. The research conducted APM experiments using a high-frequency radar installed at Dangsa Lighthouse in Dangsa-ri, Wando County, Jeollanam-do. The study compared and analyzed the results of APM experiments using ships and drones, utilizing the calculated radial currents and surface current fields obtained from each experiment.

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF