• 제목/요약/키워드: Booster section

검색결과 15건 처리시간 0.024초

Impact of Booster Section Length on the Performance of Linear Cavity Brillouin-Erbium Fiber Laser

  • Al-Mashhadani, Thamer Fahad;Jamaludin, Md. Zaini;Al-Mansoori, Mohammed Hayder;Abdullah, Fairuz;Abbas, Abdulla Khudair
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.162-166
    • /
    • 2014
  • The impact of booster section length made from passive erbium-doped fiber (EDF) on the L-band multiwavelength Brillouin-Erbium fiber laser (MBEFL) is studied experimentally in this paper. The influence on the performance of MBEFL in term of number of generated Stokes lines, tuning range and lasing threshold were investigated. A comparison was made between MBEFL without a booster section and with booster sections of different lengths. Through comparative study and at fixed BP power and 100mW of 1480 pump power, longer passive EDF length of 5m exhibits the highest average number of Stokes lines of 23 with tuning range of 14nm. In contrast, shorter passive EDF length of 1m shows the highest tuning range of 17nm and an average number of 21 Stokes lines.

증기분사냉동계의 부우스터 이젝터와 에어 이젝터의 설계조건비교에 관한 연구 (A Study on the Comparison of Design Conditions between Booster Ejector and Air Ejector in the Steam-Jet Water-Vapour Refrigeration Cycle)

  • 이창식
    • 대한설비공학회지:설비저널
    • /
    • 제7권2호
    • /
    • pp.73-79
    • /
    • 1978
  • This paper presents the experimental study on the design conditions of pressure between booster ejector and air ejector in the steam-jet water-vapour refrigeration system. In this experiment, the motive steam of booster ejector and ai. ejector was dry saturated from 6 ata to 8 ata and flash chamber pressure were about $10\∼540mmHg$ higher than mixing section in booster ejector. The investigation of air on the pressure of booster ejector was performed by changing the condenser pressure. The experimental results show that flash chamber vacuum and condenser pressure of steam-jet refrigeration cycle increased in accordance with the increase of motive steam Pressure. Among the several nozzle sires tested, No.4 nozzle were best in term of evaporator vacuum under the constant operating conditions of air ejector in condenser.

  • PDF

TreatmentWD Pulse Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Jun-Il;Lee, Sun-Min;Bo, Gak-Hwang;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.36-41
    • /
    • 2012
  • The transcranial magnetic stimulation recharges the energy storing condenser, and sends the stored energy in the condenser to the pulse shaping circuit, which then delivers it to the stimulating coil. The previous types of transcranial magnetic stimulation required a booster transformer, secondary rectifier for high voltages and a condenser for smooth type. The energy storing condenser is recharged by switching the high-voltage direct current power. Loss occurs due to the resistance in the recharging circuit, and the single-pulse output energy in the transcranial magnetic stimulation can be changed because the recharging voltage cannot be adjusted. In this study a booster transformer, which decreases the volume and weight, was not used. Instead, a current resonance inverter was applied to cut down the switching loss. A transcranial magnetic stimulation, which can simultaneously alter the recharging voltage and pulse repeats, was used to examine the output characteristics.

습식 배연탈황 시스템의 효율 향상을 위한 전산해석 (Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas)

  • 황우현;이경옥
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권2호
    • /
    • pp.161-171
    • /
    • 2014
  • 본 논문에서는 CFDRC 사의 상용 CFD 소프트웨어인 CFD-ACE+로 전산유체역학 기법을 적용하여 수치 해석을 수행하여 배연탈황 설비에서 Induced Draft Fan(I.D.Fan) 출구부터 Booster Up Fan(B.U.Fan) 입구까지 난류 유동장과 연소 유동 문제를 모사하여 배기가스 계통 설비의 유동 특성을 해석하였다. 배기가스가 I.D.Fan 출구 ~ B.U.Fan 입구 구간을 적정속도로 균일하게 유동하여 B.U.Fan로 균일하게 유입되도록 하며 압력손실이 적게 발생하도록 설계기준 보일러 부하와 최대연속 정격유량의 보일러 부하에서 이 구간의 안내깃을 검토하였다. 검토한 결과에 대해 CFD 해석을 수행하여 I.D.Fan 출구에서 안내깃을 제거하고 B.U.Fan 입구 전에 안내깃을 보강할 수 있도록 설계를 변경하였다. 배기가스 계통에 변경된 설계를 적용하여 수치모사한 결과에서 배연탈황 설비 내부의 배기가스 압력손실이 줄어들고 유속과 유선이 균일하게 유동할 수 있어 배연탈황 시스템의 효율이 향상한 것을 확인하였다.

Propulsion System Design and Optimization for Ground Based Interceptor using Genetic Algorithm

  • Qasim, Zeeshan;Dong, Yunfeng;Nisar, Khurram
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.330-339
    • /
    • 2008
  • Ground-based interceptors(GBI) comprise a major element of the strategic defense against hostile targets like Intercontinental Ballistic Missiles(ICBM) and reentry vehicles(RV) dispersed from them. An optimum design of the subsystems is required to increase the performance and reliability of these GBI. Propulsion subsystem design and optimization is the motivation for this effort. This paper describes an effort in which an entire GBI missile system, including a multi-stage solid rocket booster, is considered simultaneously in a Genetic Algorithm(GA) performance optimization process. Single goal, constrained optimization is performed. For specified payload and miss distance, time of flight, the most important component in the optimization process is the booster, for its takeoff weight, time of flight, or a combination of the two. The GBI is assumed to be a multistage missile that uses target location data provided by two ground based RF radar sensors and two low earth orbit(LEO) IR sensors. 3Dimensional model is developed for a multistage target with a boost phase acceleration profile that depends on total mass, propellant mass and the specific impulse in the gravity field. The monostatic radar cross section (RCS) data of a three stage ICBM is used. For preliminary design, GBI is assumed to have a fixed initial position from the target launch point and zero launch delay. GBI carries the Kill Vehicle(KV) to an optimal position in space to allow it to complete the intercept. The objective is to design and optimize the propulsion system for the GBI that will fulfill mission requirements and objectives. The KV weight and volume requirements are specified in the problem definition before the optimization is computed. We have considered only continuous design variables, while considering discrete variables as input. Though the number of stages should also be one of the design variables, however, in this paper it is fixed as three. The elite solution from GA is passed on to(Sequential Quadratic Programming) SQP as near optimal guess. The SQP then performs local convergence to identify the minimum mass of the GBI. The performance of the three staged GBI is validated using a ballistic missile intercept scenario modeled in Matlab/SIMULINK.

  • PDF

초음파 진동 절삭공구 혼(tool horn)의 설계에 관한 연구 (A Study on the Design of Ultrasonic Vibration Cutting Tool Horn)

  • 강종표
    • 한국정밀공학회지
    • /
    • 제8권3호
    • /
    • pp.55-63
    • /
    • 1991
  • Transforming small ultrasonic energy into large mechanical energy is the essential feature of ultrasonic vibration in various application fields. This energy amplification can be obtained by achieving resonance condition between booster or tool horn and transducer. When it has uniform section with small sectional area, one dimensional analysis provides good estimation of the natural frequency of the horn. But, for arbitrary shape of horn, one dimensional analysis can no longer be applied. At present, designing tool horn whose natural frequency is identical to that of transducer requires serveral stages of trial and error in actual manufacturing process. In this paper, frequency analysis program is developed to easily predict the natural frequency of ultrasonic vibration cutting tool with axisymmetry and 3- dimensional shape using finite element method.

  • PDF

전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구 (Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy)

  • 김명수;김성철
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1735-1742
    • /
    • 2018
  • The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

Immunogenicity of a novel inactivated canine adenovirus type 2 variant vaccine for dogs

  • Dong-Kun Yang;Sangjin Ahn;Hye Jeong Lee;Minuk Kim;Jong-Taek Kim;Ju-Yeon Lee;Yun Sang Cho
    • Clinical and Experimental Vaccine Research
    • /
    • 제13권3호
    • /
    • pp.253-258
    • /
    • 2024
  • Purpose: The immunogenicity of vaccines containing the canine adenovirus (CAdV) type 2 (CAdV-2) variant has not yet been reported. We prepared a novel inactivated CAdV-2 variant vaccine using the CAV2232-41 strain, and evaluated its safety and immunogenicity in raccoon dogs. Materials and Methods: The growth kinetics of CAV2232-41 were determined using Madin-Darby Canine Kidney (MDCK) cells. The nucleotide sequences of CAV2232 and CAV2232-41 were determined by next-generation sequencing. To generate the CAdV-2 variant vaccine, CAV2232-41 propagated in the MDCK cells was inactivated with 0.1% formaldehyde. Two vaccines were prepared by blending inactivated CAV2232-41 with Cabopol and Rehydragel adjuvants. Safety and immunogenicity of the CAV2232C and CAV2232R vaccines were evaluated in guinea pigs. Safety and immunogenicity of the CAV2232C vaccine were also evaluated in raccoon dogs. The virus neutralizing antibody (VNA) titer against CAV2232-41 was measured in sera collected from immunized guinea pigs and raccoon dogs. Results: CAV2232-41 showed the highest viral titer on days 4-6 post-inoculation and had a deletion in the E3 gene, which was confirmed as a CAdV-2 variant. Guinea pigs inoculated with CAV2232C showed slightly higher VNA titers than those inoculated with CAV2232R 2 weeks after booster vaccination. Raccoon dogs immunized with the CAV2232C vaccine developed high mean VNA titers, while non-vaccinated raccoon dogs were antibody-negative. Conclusion: The CAV2232C vaccine is safe and induces a protective VNA titer in raccoon dogs.

공동주택의 노후 급수관 개선방안에 관한 연구 : 부천시 공동주택을 중심으로 (The Replacement Plans for Aged Public Water Supply Pipes in Apartment Buildings : Especially Apartment Buildings in Bucheon)

  • 이용화;허용철
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.228-232
    • /
    • 2015
  • The water supply galvanized steel pipes of apartment buildings in Bucheon city constructed with building permission before 1994 have many problems such as leaks, the water containing rust, and low water pressure due to corrosion. Therefore, this study aims to find a way to renew the water supply pipes under investigation through a survey. As a result, when replacing the galvanized steel pipe with the corrosion-resistant pipe, the water supply system should also be changed from the gravity tank system to the booster pump system and the hygienic water storage tank. It is necessary to redraft the long-term repair plan including the replacement of the water supply system. Also, it is necessary to save the allowance reserve according to the modified long-term repair plan.

터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구 (Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance)

  • 손동기;김춘택;윤민수;차봉준;김진한;양수석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF