• Title/Summary/Keyword: Bone wire

Search Result 131, Processing Time 0.028 seconds

COMPARATIVE STUDY OF AUTOGENOUS BONE GRAFT AND GUIDED TISSUE REGENERATION IN THE TREATMENT OF PERIODONTAL DEFECT IN DOGS (성견 치조골 결손부에 자가골이식과 조직유도재생막을 이용한 치주치료시 치유효과에 관한 비교연구)

  • Hong, Ki-Seok;Kim, Jong-Yeo;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.205-216
    • /
    • 1994
  • The goal of periodontal therapy is the regeneration of the periodontium lost by periodontal disease. The purpose of this study was to evaluate the regenerative potential of the autogenous bone graft and guided tissue regeneration in the treatment of periodontal bony defect in dogs. Experimental periodontitis were induced in the mandibular left 3rd premolar and right 3rd and 4th premolars of 5 dogs using orthodontic ligature wire. After 6 weeks, the ligature wire removed, surgical procedure were performed as follows. 1) control group : Flap operation(Mn.Lt 3rd premolar) 2) experimental group I : Flap operation + autogenous bone graft (Mn.Rt. 3rd premolar) 3) experimental group II : Flap operation + Gore-Tex membrane (Mn.Rt. 4th premoalr) Thereafter, dogs were sacrificed on the 1,2,4,8,16th week and the specimens were prepared and stained with hematoxyline-eosin stain for the light microscopic examination. The results of this study were as follows. 1. The apical migration of junctional epithelium was most remarkable in the flap operation and the experimental group II was less than the experimental group I. 2. In the formation of new alveolar bone, it was found in experimental group I,II and experimental group I is more than II. In the control group, few bone formation was found. 3. In the formation of new cementum, it was found in experimental group I,II and experimental group II is more than I. So, the periodontal therapy combined with autogenous and guided tissue regeneration will be produce the periodontal regeneration.

  • PDF

Wire or Hook Traction for Reducing Zygomatic Fracture

  • Ahn, Hee Chang;Youn, Dong Hyun;Choi, Matthew Seung Suk;Chang, Jung-Woo;Lee, Jang Hyun
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.131-135
    • /
    • 2015
  • Background: Variable methods have been introduced for reduction of the zygomatic fractures. The Dingman elevator is used widely to reduce these fractures but is inappropriate in certain types of fractures which require atypical traction vectors. We introduce and examine an alternate method of reducing zygomatic fractures using wire and hook traction. Methods: A retrospective study was performed for all zygomatic fracture patients admitted between 2008 and 2014. Medially rotated fractures were reduced by using a wire looped through an intermaxillary screw secured on the medial side of the zygoma. Laterally rotated fractures were reduced using a hook introduced through an infrazygomatic skin incision. Results: No accidental bleeding or incomplete reduction was observed in any of the cases. Postoperative imaging demonstrated proper reduction immediately after the operation. Follow-up computed tomography study at 1 month after operation also demonstrated proper reduction and healthy union across the previous site of fracture. Conclusion: The hook and wire method allowed precise application of traction forces across zygomatic fractures. The fractured bone fragment could be pulled in the direction precisely opposite to the vector of impact at the time of trauma. Soft tissue damage due to dissection was minimized. In particular, this method was effective in reducing rotated bone fragments and can be an alternative option to using the zygoma elevator.

Reduction of Bowed Tibia Fracture by Fixation with Kirschner and Cerclage Wires in a Dog: A Case Report (Kirschner 철사와 원형 철사를 이용하여 개의 휘어진 경골 골절을 정복한 증례)

  • Uhm, Mi-Young;Kim, Young-Ki;Wang, Ji-Hwan;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.25 no.5
    • /
    • pp.408-410
    • /
    • 2008
  • A four months old, 3.6 kg intact female Miniature Dachshund dog was referred for non-weight bearing lameness at right hind limb due to car accident. On physical examination, the patient was non-weight bearing on the right hind leg and had moderate swelling in the proximal to middle tibia region. There was palpable crepitus. Radiographs revealed a slightly displaced, spiral, oblique fracture involving the proximal diaphyseal region of the right tibia. Fibular fracture was also noted. Internal fixation was performed to repair the fracture. Due to bowed shape of fractured tibia, it was not possible to apply K-wire, containing appropriate diameter ($60{\sim}80%$ of bone marrow diameter) for intramedullary fixation. We fixed the bowed tibia fracture using a smaller diameter (30% of bone marrow diameter) K-wire with cross pins and cerclage wires. Four weeks after the operation, radiographs demonstrated healing of the tibia fracture as well as the fibular fracture.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

Using a Kirschner wire as an internal splint at nasal fractures accompanied fracture of frontal process of maxilla or perpendicular plate of ethmoid (상악골 전두돌기 골절 및 사골 수직판 골절을 동반한 비골 골절에서 K 강선을 이용한 내고정)

  • Rho, Kyoung Hwan;Yoon, Eul Sik;Yoon, Byung Min;Dhong, Eun Sang
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Purpose: In cases where nasal fractures involve frontal process of maxilla or perpendicular plate of ethmoid, 4 - 5 days of nasal packing may not provide sufficient support for avoiding displacement after packing removal. Therefore a single Kirschner - wire(K - wire) is used as an internal splint when nasal fractures involve the above two areas. Methods: Thirty five patients during the last 3 practical years were treated with a K -wire pinning according to the anatomic locations of nasal fractures. We performed a retrospective study using 13 nasal fractures out of total 35 patients. Among 13 cases, 10 patients involved frontal process of maxilla, and 3 patients were diagnosed as bilateral nasal side wall fractures accompanied with fractures of perpendicular plate of ethmoid. One patient of the last three cases had been augmented with dorsal silicone implant long before the trauma. We analyzed the anteroposterior displacement of key stone area and the width between both lateral walls by comparing immediate postoperative radiographs with 2 month follow - ups. To reduce the errors, the same measurements were taken by two different inspectors, and the mean of each inspector's measurements was compared. Patient satisfaction was analyzed using a questionnaire regarding the esthetic and functional outcomes. Results: Ten patients underwent a longitudinal K - wire fixation in submucoperiosteal plane underneath the frontal process of maxilla. And three patients underwent a transverse K - wire fixation from the one side of lateral wall to the perpendicular plate of ethmoid and to the other side of lateral wall. The mean postoperative anteroposterior displacement of the key stone area measured by two inspectors were 1.84% and 3.06%; mean narrowing of bony pyramid were 1.33% and 1.48%, respectively. Subjective satisfaction scores regarding the esthetic appearance and the maintenance of nasal shape compared with immediate post - operative state with the long term ones were not different (p>0.05). Conclusion: K - wire pinning after closed reduction is a reliable and useful method for the treatment of nasal fractures involving frontal process of maxilla or perpendicular plate of ethmoid. This is because it achieves longer intranasal support after reduction. This method also leaves conspicuous external scar, and minimal soft - tissue injury.

Sternal Fracture Fixation with a Steel Wire: The New "Timala" Technique

  • Timala, Rabindra Bhakta;Panthee, Nirmal
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.170-176
    • /
    • 2021
  • Purpose: Traumatic sternal fractures are rare but quite disabling injuries. Timely fixation of sternal fractures reduces pain and prevents respiratory complications. However, the fixation technique should be simple, effective, and readily available in local circumstances. Methods: From January 2014 to March 2020, seven patients with sternal fracture/dislocation underwent steel wire fixation with the new "Timala" technique. In this technique, adjacent ribs are anchored with two steel wires to form an "X" in front of the fractured segment of the sternum. Patients were followed up clinically and radiologically. Results: Six of the patients were men and one was a female. Five of them had injuries due to falls and two were injured in road traffic accidents. Their age ranged from 18 years to 76 years, with a median age of 41 years. All seven patients experienced immediate recovery from pain and showed evidence of fracture healing on postoperative chest X-rays and clinical examinations. Conclusions: Anchoring ribs to fix the sternum with steel wire is a safe, effective, easily available, and reproducible method to fix sternal fractures or dislocations.

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

An experimental study of dynamic frictional resistance between orthodontic bracket and arch wire (교정용 브라켓과 강선 사이의 운동마찰저항력에 관한 실험적 연구)

  • Lee, Jae-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.467-477
    • /
    • 2001
  • This investigation was designed to determine the effects of wire size, bracket width and the number of bracket on bracket-wire dynamic frictional resistance during simulating arch wire-guided tooth movement in vitro. For simulation of an arch wire-guided tooth movement, we simulated tooth, periodontal ligament and cancellous bone. Maxillary premolar and 1st molar were simulated as real sized resin teeth, the simulated resin teeth which its root was coated by polyether impression material which its elastic modulus is similar to periodontal ligament were embedded in steel housing with inlay wax which its elastic modulus is similar to cancellous bone. Stainless steel wires in four wire size (0.016, 0.018, $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch) were examined with respect to three (stainless steel) bracket widths (2.4, 3.0, 4.3mm) and the number of medium bracket(one, two, three) included in the experimental assembly under dry condition. The wires were ligated into the brackets with elastomeric module. The results were as follows : 1. In all the brackets, frictional resistance increased with increase in wire size. But, statistically similar levels of frictional resistance were observed between 0.018 inch and $0.016\;{\times}\;0.022$ inch wires in narrow bracket and also between 0.016 inch and 0.018 inch wire in wide backet. 2. The frictional forces produced by 0.016 inch wire were statistically similar levels in all the brackets. In 0.018 inch round wire, wide bracket was associated with lower amounts of friction than both narrow and medium brackets. In $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch rectangular wire, wide bracket produced target friction than both narrow and medium brackets. In all the wirer, narrow and medium bracket demonstrated no statistical difference in levels of frictional resistance. 3. Frictional resistance increased with increase In number of medium bracket. 0.016 inch round wire demonstrated the greatest increment in frictional resistance, followed by $0.019\;{\times}\;0.025,\;0.016\;{\times}\;0.022$ inch rectangular wire which were similar level in increment of frictional resistance, 0.018 inch wire demonstrated the least increment. The increments of frictional resistance were not constantly direct proportion to number of bracket.

  • PDF

MECHANICAL ANALYSIS ON THE MULTILOOP EDGEWISE ARCH WIRE (Multiloop Edgewise Arch Wire의 역학적 해석)

  • Chun, Kyung-Min;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.21 no.1 s.33
    • /
    • pp.31-51
    • /
    • 1991
  • This study was designed to survey the stress distributions and deflections which were derived from MEAW by the computer-aided three dimensional finite element analysis of teeth and surrounding bone composed of 2839 solid elements and 4621 nodes. MEAW model was also made using the 90 beam elements and the results were expressed by quantitative and visible ways. The findings of this study were as follows. 1 In case of vertical load on the MEAW there were extrusions of anterior teeth and upright effects of the posterior teeth. 2. Without applying the vertical elastics on the MEAW there were intrusions of anterior teeth, but relatively mild force was transmitted to the posterior teeth area. Torque forces were observed on the incisors and molars, and canine was intruded without torque. 3. The magnitudes of forces were different by the amounts of tip back bends of MEAW. 4. The displacements were in inverse proportion to the cross section areas of the wires according to the experiment using the 5 different size arch wires. 5. The difference of deflections between the MEAW and plain arch wire was not so big as the theoretical one but the deflections of MEAW were much more than the plain arch wire in every X, Y, Z direction.

  • PDF

Different Bone Graft Materials in Intrabony Defects (치조골내낭에 수종의 골이식재 이식후 혈소판 유래 성장인자의 분포에 관한 면역조직화학적 연구)

  • Um, Heung-Sik;Han, Soo-Boo;Lee, Jae-Il;Kim, Hyun-Jong;Chang, Beom-Sek
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.45-59
    • /
    • 1997
  • Platelet-derived growth factor(PDGF) has been shown to play an important role in periodontal regeneration. The purpose of the present study was to examine the distribution of PDGF in experimentally created periodontal intrabony defects after flap surgery with various bone graft materials. Six healthy mongrel dogs were used in this study. Three-wall bony defects were created in maxillary and mandibular premolars, inflammation induced by wire ligation and injection of impression material into the defects. Eight weeks later, the experimental lesions thus obtained were treated by plain flap surgery(control group), flap surgery plus autogenous bone graft(autogenous bone group), flap surgery plus Biocoral graft(Biocoral group), or flap surgery plus bioglass graft(bioglass group), which were randomly assigned to the defects. After 4, H, and 12 weeks postoperatively, 2 dogs were sacrificed at each time and 1he specimens were taken for histological examinations and immunohistochemical examinations for PDGF. In the control defects the amount of new bone formation was minimal. In the autogenous bone and Biocoral group new bone was deposited around implanted particles and the amount of new bone was increased with time. A large number of bioglass particles exibited a central excabation and bone formation could be observed in the central excabation as well as around the particles. The expression of PDGF was low in the control group. The expression of PDGF in Biocoral group was increased at 1, H week, but decreased at 12 week. The increased PDGF expression in autogenous bone and bioglass group was maintained to the end of the experiment.

  • PDF