• Title/Summary/Keyword: Bone scanning

Search Result 289, Processing Time 0.025 seconds

Correlation analysis of gingival recession after orthodontic treatment in the anterior region: an evaluation of soft and hard tissues

  • Lee, Jong-Bin;Baek, Soo-Jin;Kim, Minji;Pang, Eun-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.3
    • /
    • pp.146-158
    • /
    • 2020
  • Purpose: The aim of this study was to investigate and identify the main causes of periodontal tissue change associated with labial gingival recession by examining the anterior region of patients who underwent orthodontic treatment. Methods: In total, 45 patients who had undergone orthodontic treatment from January 2010 to December 2015 were included. Before and after the orthodontic treatment, sectioned images from 3-dimensional digital model scanning and cone-beam computed tomography images in the same region were superimposed to measure periodontal parameters. The initial labial gingival thickness (IGT) and the initial labial alveolar bone thickness (IBT) were measured at 4 mm below the cementoenamel junction (CEJ), and the change of the labial gingival margin was defined as the change of the distance from the CEJ to the gingival margin. Additionally, the jaw, tooth position, tooth inclination, tooth rotation, and history of orthognathic surgery were investigated to determine the various factors that could have affected anterior periodontal tissue changes. Results: The mean IGT and IBT were 0.77±0.29 mm and 0.77±0.32 mm, respectively. The mean gingival recession was 0.14±0.57 mm. Tooth inclination had a significant association with gingival recession, and as tooth inclination increased labially, gingival recession increased by approximately 0.2 mm per 1°. Conclusions: In conclusion, the IGT, IBT, tooth position, tooth rotation, and history of orthognathic surgery did not affect labial gingival recession. However, tooth inclination showed a significant association with labial gingival recession of the anterior teeth after orthodontic treatment.

Fabrication of Nanofiber-Combined 3D Scaffolds using Dual-Head Deposition Technology (듀얼헤드 적층 기술을 이용한 나노섬유로 결합된 3D 인공지지체 제작)

  • Sa, Min-Woo;Lee, Chang-Hee;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.108-115
    • /
    • 2018
  • In bone tissue engineering, polycaprolactone (PCL) is one of the most widely used biomaterials to manufacture scaffolds as a synthetic polymer with biodegradability and biocompatibility. The polymer deposition system (PDS) with four axis heads, which can dispense bio-polymers, has been used in scaffold fabrication for tissue engineering applications. A dual-head deposition technology of PDS is an effective technique to fabricate 3D scaffolds. The electrospinning technology has been widely used to fabricate porous and highly interconnected polymer fibers. Thus, PDS can fabricate nanofiber-combined hybrid scaffolds using fused deposition modeling (FDM) and electrospinning methods. This study aims to fabricate nanofiber-combined scaffolds with uniform nanofibers using PDS. The PCL nanofibers were fabricated and evaluated according to the fabrication process parameters. PCL nanofibers were successfully fabricated when the applied voltage, tip-to-collector distance, flow rate, and solution concentration were 5 kV, 1 cm, 0.1 ml/h, and 8 wt%, respectively. The cell proliferation was evaluated according to the electrospinning time. Scanning electron microscopy was used to acquire images of the cross-sectioned hybrid scaffolds. The cell proliferation test of the PCL and nanofiber-combined hybrid scaffolds was performed using a CCK-8 assay according to the electrospinning time. The result of in-vitro cell proliferation using osteosarcoma MG-63 cells shows that the hybrid scaffold has good potential for bone regeneration.

Chondrogenic Differentiation of Bone Marrow Stromal Cells in Transforming Growth $Factor-{\beta}_{1}$ Loaded Alginate Bead

  • Park, Ki-Suk;Jin Chae-Moon;Kim, Soon-Hee;Rhee John M.;Khang Gil-Son;Han, Chang-Whan;Yang, Yoon-Sun;Kim, Moon-Suk;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • v.13 no.4
    • /
    • pp.285-292
    • /
    • 2005
  • We developed alginate beads loaded with transforming growth $factor-{\beta}_{1}(TGF-{\beta}_{1})$ to examine the possible application of the scaffold and cytokine carrier in tissue engineering. In this study, bone marrow stromal cells (BMSCs) and $TGF{\beta}_{1}$ were uniformly encapsulated in the alginate beads and then cultured in vitro. The cell morphology and shape of the alginate beads were observed using inverted microscope, scanning electron microscope (SEM), histological staining and RT-PCR to confirm chondrogenic differentiation. The amount of the $TGF{\beta}_{1}$ released from the $TGF-{\beta}_{1}$ loaded alginate beads was analyzed for 28 days in vitro in a phosphate buffered saline (pH 7.4) at $37^{\circ}C$. We observed the release profile of $TGF-{\beta}_{1}$ from $TGF-{\beta}_{1}$ loaded alginate beads with a sustained release pattern for 35 days. Microscopic observation showed the open cell pore structure and abundant cells with a round morphology in the alginate beads. In addition, histology and RT-PCR results revealed the evidence of chondrogenic differentiation in the beads. In conclusion, these results confirmed that $TGF-{\beta}_{1}$ loaded alginate beads provide excellent conditions for chondrogenic differentiation.

Preparation and Characterization of Pamidronate-loaded PLGA Wafer for the Treatment of Bone Resorption (골 재흡수 치료를 위한 파미드로네이트를 함유한 이식형 생분해성 PLGA 웨이퍼의 제조와 특성결정)

  • 유제영;김상욱;강길선;성하수;정제교
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.680-690
    • /
    • 2002
  • Implantable biodegradable wafers were prepared with pamidronate -loaded poly (L-lactide-co-glycolide) (PLGA, 75 : 25 mole ratio by lactide to glycolide, molecular weight : 20000 and 90000 g/mole) by direct compression method for the sustained release of pamidronate to investigate the possibility for the treatment of bone resorption. Pamidronate-loaded PLGA powders were prepared by means of physical mixing and spray drying with the control of formulation factors and characterized by scanning electron microscope and X-ray diffractometer. The pamidronate-loaded PLGA powders fabricated into wafers by direct compression under the constant pressure and time at room temperature. These wafers were also observed for their structural characteristic, release pattern, and degradation pattern. The release rate of pamidronate increased with increasing their initial loading ratio as well as increasing wafer thickness. The molecular weight of PLGA affects the release pattern : the higher molecular weight of PLGA, the faster release rate. It can be explained that the higher viscosity of high molecular PLGA solution at same concentration tends to aggregate PLGA and pamidronate resulting in unstable pharmaceutical dosage form. This system had advantages in terms of simplicity in design and obviousness of drug release rate and nay be useful as an implantable dosage form for the treatment of aural cholesteatoma.

The Effect of Solvents on Sold Dispersion of Ipriflavone with Polyvinylpyrrolidone In Vivo

  • Jeong, Je-Kyo;Ahn, Yong-San;Moon, Byung-Kwan;Choi, Myung-Kyu;Khang, Gil-Son;Rhee, John-M.;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • ABSTRACT -Ipriflavone is a synthetic flavonoid derivate that improves osteoblast cell activity inhibiting bone resorption. In order to improve the bioavailability, solid dispersions of ipriflavone with PVP (poly-N-vinylpyrrolidone, MW=40,000 g/mole) were prepared by a spray-drying method. During the manufacturing of solid dispersion, various solvents [ethanol (EtOH), acetonitrile, methylene chloride and cosolvent-EtOH:acetone=1:1] were used to dissolve the ipriflavone and PVP. Scanning electron microscopy (SEM) and differential scanning calorimetry (DSC) were used to evaluate the physicochemical interaction between ipriflavone and PVP. Particle size, crystallinity and the area of the endotherm $({\Delta}H)$ of solid dispersed ipriflavone using the acetonitrile as solvent were much smaller than those of the other preparation types. Bioavailability of ipriflavone in vivo was changed by solvents. When considering the result of in vivo test, solid dispersion of ipriflavone using the acetonitrile as solvent showed the best choice.

ON THE SURFACE CHARACTERISTICS AND STABILITY OF IMPLANT TREATED WITH ANODIZING OXIDATION (양극산화 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Kim, Won-Sang;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.549-560
    • /
    • 2006
  • Purpose : This experiment examined the effects of anodization on commercially pure titanium implant fixtures. Material & methods : The implant fixtures were anodized at three different voltage levels, producing three different levels of oxidation on the surface of the fixure. Implant were divided into four groups according to the level of oxidation. Group 1 consist of the control group of machined surface implants, Group 2 implants were treated by anodizing to 100 voltage, Group 3 implants were treated by anodizing oxidation to 200 voltage Group 4 implants were treated by anodizing oxidation to 350 voltage. Surface morphology was observed by Scanning Electron Microscope(SEM) and the surface roughness was measured using NanoScan $E-1000^{\circledR}$. Implantation of the fixtures were performed using New Zealand white rabbits. $Periotest^{\circledR}$ value(PTV) resonance frequency analysis(RFA), and removal torque were measured in 0, 2, 4, 8, 12 weeks after implantation. Results : The results of the study were as follows: 1. Values for the measured surface roughness indicate statistically significant differences in Ra, Rq, and Rt values among group 1, 2, 3, and 4 at the top portion of the thread,(p<0.05) while values at the base of the threads indicated no significant difference in these values. 2. A direct correlation between the firming voltage, and surface roughness and irregularities were observed using scanning electron microscope. 3. No statistically significant differences were found between test groups regarding $Periotest^{\circledR}$ values. 4. Analysis of the data produced by RFA, significant differences were found between group 1 and group 4 at 12 weeks after implantation.(p<0.05) Conclusions : In conclusion, no significant differences could be found among test groups up to a certain level of forming voltage threshold, beyond this firming voltage threshold, statistically significant differences occurred as the surface area of the oxide layer increased with the increase in surface porosity, resulting in enhanced bone response and osseointegration.

Finite Element Analysis of Sound Transfer Characteristics for Middle Ear (유한요소 모델을 이용한 중이의 소리전달 특성 해석)

  • Gal, Young-Min;Baek, Moo-Jin;Lee, Doo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1563-1571
    • /
    • 2011
  • In this study, we developed a finite element model of the human middle ear has been developed to calculate itsfor sound transfer characteristics calculation. We usedThe geometric data forof ossicles, obtained byfrom micro-CT scanning, was used in order to develop the middle- ear FE model. A right- side temporal bone of a Korean cadaver was used for the micro-CT scanning. The developed FE model includes three ossicles, the tympanic membrane, ligaments, and muscles. We calculated theA sound transfer function from the tympanic membrane to the stapes footplate was calculated. The sound transfer function calculated vias of the FE model shows good agreement with measured responses over the 10- kHz frequency band. To measureidentify the sensitivityies of the middle- ear function due to material property variation, we studied several parameters studies have been fulfilled using the middle ear FE model. TAs a result the stiffness property of the incudostapedial joint had the greatest influence onwas the most influential to the middle- ear sound transfer function among the parameters.

Significance of Diffuse Lung Uptake of $^{99m}Tc-Tin$ Colloid in Liver Scanning (간스캔상 $^{99m}Tc-Tin$ Colloid의 미만성 폐섭취의 의의)

  • Sohn, In;Kwon, In-Soon;Park, Jung-Sik;Lee, Myung-Chul;Cho, Bo-Yeon;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 1983
  • Sixty-nine patients with diffuse lung uptake of $^{99m}Tc-tin$ colloid were evaluated to determine the kinds of associated diseases, the incidence of associated liver scan abnormalities, and prognosis. The results were as follows: 1) Diseases associated with diffuse lung uptake included malignancies in 31 patients, infectious diseases in 19, chronic liver diseases in 14, and others in 5. It appeared that the marked degree of lung uptake was associated with severe diseases. 2) Thirty-one of the 69 patients(45%) had abnormal liver size, 43(62%) had space occupying lesions or nonhomogeneity in liver image, 37(54%) had splenomegaly and 45(65%) had increased splenic uptake. Increased bone marrow uptake was found in 48(70%) and renal uptake in 15(22%). As the degree of lung uptake increased, there was a statistically significant (p<0.05) tendency for the incidences of the abnormal liver image and renal uptake to increase. 3) Sixty-two of the 69 patients were followed up for one to 439 days(mean 44 days) after liver scanning. Eleven(18%) were dead, 10(16%) were aggravated, and 13(21%) were improved. Most of improved patients had infectious diseases. It appeared that diffuse lung uptake of $^{99m}Tc-Tn$ colloid was found in the various diseases including malignancies, infections, and chronic liver diseases, and that it was strongly associated with other liver scan abnormalities, but was not necessarily associated with a poor prognosis, particularly when underlying diseases were infections.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY OF IMPLANT SURFACE AFTER Er,Cr:YSGG LASER IRRADIATION (Er,Cr:YSGG 레이저를 조사한 임플란트 표면의 주사전자현미경적 연구)

  • Jo, Pil-Kwy;Min, Seung-Ki;Kwon, Kyung-Hwan;Kim, Young-Jo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.454-469
    • /
    • 2006
  • Today, there is considerable evidence to support a cause-effect relationship between microbial colonization and the pathogenesis of implant failures. The presence of bacteria on implant surfaces may result in an inflammation of the peri-implant mucosa, and, if left untreated, it may lead to a progressive destruction of alveolar bone supporting the implant, which has been named as peri-impantitis. Several maintenance regimens and treatment strategies for failing implants have been suggested. Recently, in addition to these conventional tools, the use of different laser systems has also been proposed for treatment of peri-implant infections. As lasers can perform excellent tissue ablation with high bactericidal and detoxification effects, they are expected to be one of the most promising new technical modalities for treatment of failing implants. It is introduced that Er,Cr:YSGG laser, operating at 2780nm, ablates tissue by a hydrokinetic process that prevents temperature rise. We studied the change of the titanium implant surface under scanning electron microscopy after using Er,Cr:YSGG laser at various energies, irradiation time. In this study, Er,Cr:YSGG laser irradiation of implant fixture showed different effects according to implant surface. Er,Cr:YSGG laser in TPS surface with RBM not alter the implant surface under power setting of 4 Watt(W) and irradiation time of 30sec. But in TPS surface with $Ca_3P$ coating alter above power setting of 2W and irradiation time of 10sec. TPS surface with RBM showed microfracture in 4W, 30sec and TPS surface with $Ca_3P$ coating showed destruction of fine crystalline structure, melting in excess of 2W, 10sec. We concluded that proper power setting, air, water of each implant surface must be investigated and implant surface must be irradiated under the damaged extent.

A STUDY ON THE HISTOLOGIC RESPONSE OF REPLANTED TEETH PRETREATED WITH SEVERAL FLUORIDE COMPOUNDS (수종(數種)의 불소제재(弗素製材)에 의해 전처치(前處置)된 재식(再植) 치아(齒牙)의 조직학적(組織學的) 반응(反應)에 관(關)한 연구(硏究))

  • Kim, Eun-Sook;Kim, Jong-Soo;Kim, Jong-Yeo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.2
    • /
    • pp.361-382
    • /
    • 1997
  • The effect of fluoride pretreatment upon root resorption after delayed replantation was studied in beagle dogs. Upper and lower incisors were extracted and bench dried for 45 minutes. 1% Stannous fluoride solution, 2% neutral sodium fluoride gel and 1.23% acidulated phosphate fluoride gel were used for the pre-treatment of replanted root surface in the experimental groups. Replantation was done with no treatment in control group. After of an experimental periods 3 weeks, animals were sacrificed by perfusion followed by sample preparation. A histomorphometric method was applied for evaluation of tissue reactions observed in each group under light microscope. Scanning electron microscopic observation was done to find out any different surface topography between groups. The results were as follows: 1. Fluoride-treated groups showed in general the better healing patterns than untreated control group. 2. Comparisons between three experimental groups revealed the general superiority of APF-treated group over the other groups in terms of tissue healing reaction by showing the highest frequency in uncomplicated healing pattern and surface resorption and the lowest in inflammatory resorption, but with no statistical significance(p>.05). 3. Scanning elecron micrographs showed the irregular distribution of resorption cavities and the attached bone of variable size and shape in all groups. 4. It can be concluded that the types of fluoride did not have significant impact on the early tissue reactions after delayed replantation under the condition of the present experiment.

  • PDF