• Title/Summary/Keyword: Body scan

검색결과 574건 처리시간 0.023초

3차원 인체 형상의 공극거리 측정 방법 효율성 향상을 위한 연구 (Improvement of Cross Sectional Distance Measurement Method of 3D Human Body)

  • 김민경;남윤자;한현숙;최영림
    • 한국의류산업학회지
    • /
    • 제13권6호
    • /
    • pp.966-971
    • /
    • 2011
  • This study is designed to develop programs that analyze the distance of clothes from human skin and cross-sectional body figures based on 3D human body scan data, and to verify accuracy and efficiency of the program so that it can be used for clothing fit evaluation and 3D human body research. The auto cross-sectional imaging program was developed by using Visual C++ and OpenGL, and the 3D human body scan data were adopted to measure the space between skin and clothing. The space measurements were obtained by two widely used programs, RapidForm and AutoCAD, and a program devised by the researchers of this study. Measuring time and space measurements from different programs were compared in order to verify accuracy and efficiency of the newly-devised program. As a result, no significant difference was found in the measurements. However, the required time to measure one cross section was different within the significance level of 0.05, and the differences become more remarkable as the number of measuring and the angle of space between skin and clothing increase. Therefore, the program developed by this study is expected to be useful for research on body shapes and fit evaluation based on 3D human body scan data in the fashion field.

감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 - (The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image -)

  • 정은미;정우영;류재광;김동석
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.208-213
    • /
    • 2008
  • 목적 : 전신 뼈 검사는 핵의학 에서 가장 많이 수행하는 대표적인 검사로서 서울아산병원 핵의학과에서는 다양한 감마 카메라(Philips BRIGHTVIEW, PRECEDENCE, Siemens - ECAM, ECAM signature, ECAM Plus, SYMBIA T2, GE - INFINIA)를 사용하여 검사를 시행하고 있다. 그러나 각각의 감마카메라는 같은 검사를 수행할지라도 여러 요인에 의해서로 다른 민감도를 가지며, 이는 전신 뼈 검사의 추적검사에 있어 진단의 일관성을 저해하는 요인이 되기도 한다. 따라서 전신 뼈 검사 시 주사 후 검사시간, 수분섭취량, 신진 대사 정도 등의 통제 불가능한 인자들은 제외하고 최소한의 통제 할 수 있는 감마카메라 그 자체의 민감도 보정을 목적으로, 본 연구에서는 각각의 감마카메라의 민감도를 측정하여 전신 뼈검사를 추적 검사(follow-up)로 시행하였을 경우 보정할 수 있는 합리적인 보정계수 산출에 대한 연구를 하였다. 실험재료 및 방법 : 각 감마카메라의 민감도 측정은 IAEA에서 권고하는 면 선원 민감도 측정 방법에 따라 BRIGHT-VIEW, PRECEDENCE, ECAM, ECAM signature, ECAM Plus, SYMBIA T2, INFINIA의 감마카메라 7대를 분석하였다. 민감도 측정을 위한 $^{99m}Tc$ 면 선원은 전신 뼈 검사에 일반적인 계수율인 4~7 Kcps를 기준으로 제작하였다. 모든 감마카메라는 저 에너지 고 분해능용 평행다중구멍 조준기 (Low Energy High Resolution multi parallel Collimator)를 장착하였고, 15%의 Window Width, 140-keV photopeak로 설정하였다. $^{99m}Tc$ 면 선원을 조준기에 최대한 밀착시킨 후 60초, 120초 동안 계수를 측정하여 보정계수를 산출하였다. $^{99m}Tc$ 면 선원으로 산출한 보정계수를 실제 환자 전신 뼈 검사에 적용시킬 수 있는지 확인하기 위하여 27명의 환자를 대상으로 전신 뼈 검사를 수행하고 보정계수를 적용 후 비교 분석하였다. 결과 : $^{99m}Tc$ 면 선원을 이용하여 실험한 결과, 각 감마카메라의 민감도는 ECAM plus가 가장 높았으며 ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, INFINIA, PRECEDENCE 감마카메라 순으로 관찰되었다. 이를 기초로 하여 상대적으로 중간 정도의 민감도를 갖는 ECAM 감마카메라를 기준으로 보정계수를 산출했을 때 각각 1.07, 1.05, 1.03, 1.00, 0.90, 0.83, 0.72로 분석되었다. $^{99m}Tc$ 면 선원의 실험을 통해 산출한 보정계수와 전신 뼈 검사로 산출된 보정계수의 차이를 분석하였을 때 통계적으로 유의한 차이가 없었다(p<0.05). 결론 : 암환자의 골 전이 진단에 있어 전신 뼈 검사는 예민도가 높고 비침습적이며 비교적 쉽게 시행할 수 있는 장점이 있어 추적검사로 널리 이용되고 있다. 그러나 추적 검사로 전신 뼈 검사를 시행할 경우 연속적으로 동일한 감마카메라만을 사용하는 것은 여건상 불가능하며, 동일한 감마카메라를 사용한다 하더라도 시간의 경과에 따른 장비의 효율에 변화를 고려하지 않을 수 없다. 따라서 서로 다른 감마카메라를 대상으로 산출된 민감도 보정계수의 임상적 적용은 정기적으로 전신 뼈 검사를 받는 환자의 진단에 일관성을 더 해 줄 수 있을 것으로 기대된다.

  • PDF

슬림 핏(Slim-fit) 드레스 셔츠 패턴 설계를 위한 3D Body Scan Data 활용에 관한 연구 -40대 남성을 중심으로- (3D Body Scan Data Analysis for the Slim-fit Dress Shirts Pattern Design -Focused on the 40s Male-)

  • 신경희;서추연
    • 한국의류학회지
    • /
    • 제38권1호
    • /
    • pp.97-109
    • /
    • 2014
  • This study developed a functional dress shirt for adult males that reflected the body surface variation of a human body section by motion. This study conducted a 3D body scan for 8 subjects in their 40's based on the Size Korea 2010 database. Data recorded the proper posture change value and body surface change value to develop functional dress shirts for adult males. We scanned the subjects with a 3D body scanner for five primarily male wearing dress shirts and operating postures, right standing, arms raised to $90^{\circ}$ horizontal forward position, arms raised $90^{\circ}$ to the horizontal position side, lift up the arm $180^{\circ}$, and arm forward $90^{\circ}$ in a bent posture. We analyzed the 3D scan data from those motions to examine change of length using 3D software Rapidform XOS. The results indicated that the body surface sections with contraction were the front and rear shoulder area, armpit and central length as well the width of arms at more than 10%. The increased body section included the body and armpit back length; in addition, the rear arm vibration girth and under arm girth were more than 10%. In order to reflect the size variation of for each motion, the ease amount of the front and rear shoulder length and width needs to be reduced 20% because it affects the shoulder length during the right standing. The results suggest that the ease amount of the shoulder length should be minimal. The ease amount of the back size needs to be 0.5-2cm bigger and set 0.5-1.5cm longer than the dress shirt length side drooping to compensate for the side length shortage of each motion. The sleeve length needs to be 0-0.5cm shorter, and ease amount of the girth of sleeve bottom needs to be reduced 0-0.7cm due to the size variation of arms. However, the girth of the rear arms is suggested to be 0-0.6cm longer in the ease amount to the rear arm girth as the extension is more than 10% over the width and length of each motion.

전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질 (Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations)

  • 조평곤;김유현;최종학;이기열;김형철;김장섭;신동철;이성현;이준협;신귀순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.453-460
    • /
    • 2009
  • 슬라이스 두께(slice thickness)와 선속시준(beam collimation, BC)의 변화에 따른 CT gantry aperture 내의 선량 분포와 영상의 질을 알아보고자 하였다. CT장치로는 64-slice MDCT 스캐너(Brilliance 64, Philips, Cleveland, USA)를 사용하였다. 피사체가 없는 경우(air scan)의 선량측정을 위해 CT용 전리함을 gantry aperture내의 회전중심점(isocenter)과 12시, 3시, 6시, 9시 방향에서 회전중심점으로부터 5 cm 간격으로 30 cm까지 BC를 변화시키면서 각각 측정 하였다. 또한 5개의 구멍(팬텀의 중심과 12시, 3시, 6시, 9시 방향)으로 구성된 CT head and body dose phantom을 gantry aperture 내에 위치시키고 각 지점에서 선량을 측정하였다. Gantry aperture 내 피사체의 위치변화에 대한 영상의 노이즈를 비교하기 위해서 AAPM CT용 팬텀의 물통을 회전중심점과 12시 방향으로 5 cm와 10 cm 이동시킨 후 BC를 변화시키면서 스캔한 후 팬텀의 중심과 12시, 3시, 6시, 9시 방향의 지점에서 노이즈를 측정하였다. 이 중에서 몇 군데의 위치는 영상 영역에서 벗어나서 측정 할 수가 없었다. 이때 노이즈 측정을 위해서 영상재구성의 슬라이스 두께는 5 mm로 하였다. 측정한 결과 다음과 같은 결론을 얻었다: 첫째, CTDIw는 회전중심점으로부터 멀어질수록, BC가 넓어질수록 감소하였다. 둘째, BC의 넓이가 비슷한 경우의 CTDIw는 거의 유사한 값을 보였다. 즉, CTDIw는 검출기 배열의 수나 화소의 크기 보다는 전체적인 BC의 넓이에 의존하고 있음을 알 수 있었다. 셋째, air scan과 phantom scan 경우 모두에서 CTDIw는 BC가 증가될수록 감소하였다. 그러나 air scan의 경우보다 head phantom scan 시 약 30%, body phantom scan 시 약 52% 정도 CTDIw의 값이 감소하였다. 넷째, BC와 팬텀의 위치 변화에 따른 노이즈 값은 $2{\times}0.5\;mm$의 BC을 제외하고는 head phantom scan한 경우 3.9~5.9, body phantom scan한 경우 5.3~7.4로 나타나, BC와 팬텀의 위치변화에 따라서 큰 차이가 없었다. 따라서 피사체의 위치가 gantry aperture 내 SFOV(scan field of view)에 포함될 경우 회전중심점에 정확하게 위치시키지 않아도 영상의 질에는 많은 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계 (Development of Men Slacks Pattern Using 3D Scan Data)

  • 손부현
    • 대한가정학회지
    • /
    • 제46권9호
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

천해용 Side Scan Sonar의 송수신 시스템 구현 및 운용에 관한 연구 (Development of a Side Scan Sonar System for Underwater Sun)

  • 오영석;이철원;강도욱;우종식
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.222-227
    • /
    • 2000
  • "Side scan sonar" using acoustic signal has been developed to survey cable laying, sunken bodie\ulcorner bottom and so on. It use the acoustic signals, which are emitted from two transducer arrays, to get gemetri\ulcorner target area. This system consists of transceiver board, towed body, and deck unit. The transceiver board, w\ulcorner watertight canister of the towed body, controls the transmitting and receiving of 400kHz acoustic signals from \ulcorner After receiving the scattered signals, it processes the filtering, AGF(Automatic Gain Control), TVG(Time Heterodyne. The deck unit is composed of the signal processing part, A/D converter, power supplier, and real\ulcorner And the towed body has been designed to satisfy the optimal hydrodynamic behavior during towing. The de\ulcorner theory of transceiving part and some results from field-experiments will be introduced here.

  • PDF

StereoLithography로 3차원 형상가공을 위한 레이저 조사경로 생성에 관한 연구 (A study on laser scan path generation for manufacturing 3-dimensional body using StereoLithography)

  • 안대건;김준안;이석희;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.687-692
    • /
    • 1993
  • This paper deals with the generation of laser scan path for manufacturing 3-dimensional body using StereoLithography. The purpose of this study is to develop one module of the StersoLithography system(SLA) for Rapid Protyping and Manufacturing. AutoCAD system is used to supply CAD information from model. The X-Y controller which was made for a special purpose is used to test this system. The system software developed is composed of 3 main modules, the first module is calculating the boundary point os laser scan path. The scound module is generating final output file which is used to down load on the controller. The result of this study shows a good algorithm to generate laser scan path on the basis of simple mathematical background.

  • PDF

임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례 (Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report)

  • 신석현;박찬익;강세하;문지은;오민석;박철민;전우진;한성구;김선재;최수진
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.245-256
    • /
    • 2023
  • 임플란트 고정성 보철물 제작 시 디지털 시스템을 이용하여 수복할 때, 3차원적인 임플란트 위치의 구내 스캔과 임시 의치 혹은 임시 보철물 장착 후 구내 스캔을 이용한 이중 디지털 스캐닝(double digital scanning) 기법이 필요하다. 구내 스캔 시, 스캔 바디를 안정적인 랜드마크로 이용하면 다지털 인상의 정확도 향상과 기공과정이 효율적이고 단순화될 수 있다. 본 증례는 완전 디지털 시스템을 활용하여 맞춤형 치과용 임플란트 지대주 및 임시 보철물, 최종 보철물을 계획하고 제작하였다. 임플란트 식립 후, 임플란트에 체결한 구내 스캔 바디와 임시 의치 조직면에 인기 된 구내 스캔 바디의 스캔 영역을 중첩하였다. 중첩된 파일에서 임시 의치의 수직 고경에 맞는 맞춤형 치과용 임플란트 지대주와 임시 보철물을 제작하여 환자에게 시적 하였고, 임시 보철물을 토대로 최종 보철물을 제작하였다. 임시 의치 제작 시 설정한 수직 고경, 중심위 등을 최종 보철물까지 활용하여 기능 및 심미적으로 만족할 만한 결과를 얻어 이를 보고하고자 한다.

인체의 3차원 스캔 데이터를 이용한 밀착 바디 슈트 개발 (2D Pattern Development of Tight-fitting Bodysuit from 3D Body Scan Data for Comfortable Pressure Sensation)

  • 정연희
    • 한국생활과학회지
    • /
    • 제15권3호
    • /
    • pp.481-490
    • /
    • 2006
  • Adjusting pressure level in the construction of athletes' tight-fitting garments by reducing the elastic knit pattern is a challenging subject, which influences the performance of the wearer directly. Therefore, in this study, relationship between the reduction rates of the basic pattern obtained from 3D human scan data and resultant clothing pressure was explored to improve the fit and pressure exerted by clothing. 3D scan data were obtained using Cyberware and they were transformed into a flat pattern using software based on Runge-Kutta method. Reduction rate was examined by subjective wear test as well as objective pressure measurement. As a result, difference in the length between the original 3D body scan data and the 2D tight-fitting pattern was 0.02$\sim$0.50cm (0.05$\sim$1.06%), which was within the range of tolerable limits in making clothes. Among the five garments, the 3T-pattern was superior in terms of subjective sensation and fit. The pressure of the 3T pattern was 2$\sim$4 gf/cm2 at five locations on the body, which is almost the same or a bit higher than that of Z-pattern. In the case of tight-fitting overall garment, the reduction rate of the pattern in the wale direction is more critical to the subjective sensation than the course direction. It is recommended that the reduction grading rules of course direction should be larger than that of Ziegert for a better fit of tight-fitting garments. In the case of wale direction, however, reduction grading rule should be kept the same as suggested earlier by Ziegert (1988).

  • PDF

고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정 (Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy)

  • 윤재식;이재곤;이기현;임광석;최학기;이상미
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.98-103
    • /
    • 2014
  • 갑상선 분화암 환자의 방사선 치료에서 I-131의 유효반감기는 환자에게 투여하는 양의 계산뿐만 아니라 환자의 격리 입원기간의 결정, 환자로부터 가족들이 받게 되는 선량을 계산하는데 유용한 값이다. 하지만 이 값은 물리적반감기와는 달리 실측을 해야만 얻을 수 있어 입원 격리중인 환자에게 계측하기가 기술적으로 어려운 문제가 있다. Dual time I-131 whole body scan의 초기촬영과 지연촬영 사이의 체내잔류방사능량을 이용하여 전신과 갑상선에 유효반감기를 추정해 보았다. 또한 혈중 크레아티닌 농도, GFR, 투여량이 유효반감기와 상관관계가 있는지 알아보았다. 유효반감기 측정을 위해 전신에 체내잔류방사능량과 갑상선의 잔류방사능량을 측정하기 위해 환자의 전신을 흥미영역으로 설정한 후 배후방사능을 보정하여 전신의 체내잔류방사능량을 획득하였고, 갑상선 부위에 ROI를 설정한 후 배후 방사능을 보정하여 갑상선의 잔류방사능량을 획득하였다. 초기영상과 지연영상의 측정값 사이의 비율을 계산하여 전신과 갑상선의 유효반감기를 구하였다. 또한 유효반감기와 GFR, 혈중크레아티닌 농도, I-131 투여량과의 상관관계를 분석하였다. 전신의 체내잔류방사능량을 측정한 값의 유효반감기는 $17.06{\pm}5.50$시간으로 나타났고 갑상선의 잔류방사능량을 측정한 값의 유효반감기는 $17.22{\pm}5.41$시간으로 나타났으며 두 유효반감기는 유의한 차이를 보이지 않았다(P=0.887). GFR 값이 올라갈수록 전신의 유효반감기(r=-0.407, P=0.003)와 갑상선 유효반감기(r=-0.473, P=0.001) 모두 유의하게 감소하였으며 혈중크레아티닌 농도가 올라갈수록 전신의 유효반감기(r=0.309, P=0.029)와 갑상선 유효반감기(r=0.371, P=0.008) 모두 유의하게 증가하였다. 투여량은 두유효반감기와 상관관계를 보이지 않았다. 본 연구를 통해 고용량 방사성요오드 치료환자 입원기간의 최적화 연구와 기존 유효반감기를 구하기 위해 종사자의 피폭 및 복잡성을 보완하여 간편하게 측정을 할 수 있을 것이라 생각한다. 또한 분석된 갑상선의 유효반감기를 적용한 MIRD schema의 내부피폭선량 평가 연구에도 활용할 수 있을 것으로 사료된다.

  • PDF