• Title/Summary/Keyword: Bode Plot

Search Result 52, Processing Time 0.018 seconds

A Study on the Diagnosis of Secondary Battery by Phase Response (위상응답에 의한 이차전지의 진단에 관한 연구)

  • Park, Seung-Gon;Kang, Dea-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.99-104
    • /
    • 2019
  • It was proposed the use of an inducive element to measure the SOH of a secondary battery by phase response. As a result of simulating the Randles equivalent model of a secondary battery, the inductive element used as the load has a high response characteristic and increases the maximum phase response frequency band. In order to obtain the frequency band in which the phase response characteristic of the secondary battery is well observed, the phase response was measured with the change of the inductance value of the inductive element, 33uH,49mohm inductive element with the maximum phase response at 631Hz was used. The phase response measurements for secondary battery with different SOH showed that the phase response for each 20% of SOH showed a difference of about 3.8(degree), enabling the SOH diagnosis of secondary battery by the phase measurement for the inductive element.

Parameter Estimation by OE model of DC-DC Converter System for Operating Status Diagnosis

  • Jeon, Jin-Hong;Kim, Tae-Jin;Kim, Kwang-Su;Kim, Kwang-Hwa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.206-210
    • /
    • 2004
  • This paper deals with a parameter estimation of the DC-DC converter system for its diagnosis. Especially, we present the results of parameter estimation for the DC-DC converter model by the system identification method. The parameter estimation for the DC-DC converter system aims at the diagnosis of its operating status. For the operating status diagnosis of the DC-DC converter system, we assume that the DC-DC converter system is an equivalent model of the Buck converter and estimate the main parameter for on-line diagnosis. In addition, for verification of an estimated parameter, we compare a bode plot of the estimated system transfer function and measurement results of the HP4194 instrument. It is a control system analyzer for system transfer function measurement. Our results confirm that the main parameter for diagnosis of the DC-DC converter system can be estimated by the system identification method and that the aging status of the system can be predicted by these results on operating status.

Effect of R-C Compensation on Switching Regulation of CMOS Low Dropout Regulator

  • Choi, Ikguen;Jeong, Hyeim;Yu, Junho;Kim, Namsoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.172-177
    • /
    • 2016
  • Miller feedback compensation is introduced in a low dropout regulator (LDO) in order to obtain a capacitor-free regulator and improve the fast transient response. The conventional LDO has a limited bandwidth because of the large-size output capacitor and parasitic gate capacitance in the power MOSFET. In order to obtain a stable frequency response without the output capacitor, LDO is designed with resistor-capacitor (R-C) compensation and this is achieved with a connection between the gain-stage and the power MOS. An R-C compensator is suggested to provide a pole and zero to improve the stability. The proposed LDO is designed with the 0.35 μm CMOS process. Simulation testing shows that the phase margin in the Bode plot indicates a stable response, which is over 100o. In the load regulation, the transient time is within 55 μs when the load current changes from 0.1 to 1 mA.

The Stability Improvement of Brushless DC Motor by Digital PI Control (디지털 PI제어에 의한 브러시리스 직류모터의 안정도 향상)

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin;Im, Tae-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.38-46
    • /
    • 2000
  • This study have established proper mathematical equivalent model of Brushless DC (BLDC) motor and estimated the motor parameter by means of the back-emf measurement as being the step input to the controlled target BLDC motor. And the validity of proposed estimation method is confirmed by the test result of step response. As well, we have designed the reasonable digital controller as a consequence of the root locus method which is obtained from the open-loop transfer function of BLDC motor with hall sensor, and the determination of control gain for variable speed control. Here, revised Ziegler-Nichols tuning method is applied for the proper digital gain establishment, and the system stability is verified by the frequency domain analysis with Bode-plot and experimentation.

  • PDF

Modeling and Feedback Control of LLC Resonant Converters at High Switching Frequency

  • Park, Hwa-Pyeong;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.849-860
    • /
    • 2016
  • The high-switching-frequency operation of power converters can achieve high power density through size reduction of passive components, such as capacitors, inductors, and transformers. However, a small-output capacitor that has small capacitance and low effective series resistance changes the small-signal model of the converter power stage. Such a capacitor can make the converter unstable by increasing the crossover frequency in the transfer function of the small-signal model. In this paper, the design and implementation of a high-frequency LLC resonant converter are presented to verify the power density enhancement achieved by decreasing the size of passive components. The effect of small output capacitance is analyzed for stability by using a proper small-signal model of the LLC resonant converter. Finally, proper design methods of a feedback compensator are proposed to obtain a sufficient phase margin in the Bode plot of the loop gain of the converter for stable operation at 500 kHz switching frequency. A theoretical approach using MATLAB, a simulation approach using PSIM, and experimental results are presented to show the validity of the proposed analysis and design methods with 100 and 500 kHz prototype converters.

Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석)

  • Jo, Jongmin;Lee, Taejin;Yun, Donghyun;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.

Controller Design of Stand-Alone or Grid-Connected Inverter to Compensate Harmonics Caused by Nonlinear Load (비선형부하에 의해 발생하는 고조파 보상을 위한 독립형 또는 계통연계형 인버터 제어기 설계)

  • Sin, Chanho;Lim, Kyungbae;Petrus, Simatupang Desmon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.440-448
    • /
    • 2017
  • This paper proposes a controller design of a distributed source inverter in stand-alone mode or grid-connected mode to compensate the current or voltage harmonics caused by local nonlinear load. The PR-based multi loop controller has been used to improve the dynamic performance of the system and to compensate the output voltage or grid current harmonics. The multi-loop controller consists of an outer current controller and an inner voltage controller for the output voltage control in stand-alone mode. In grid-connected mode, an outer current controller is added to the output voltage controller for the grid current control. The design performance of each controller is described through the Root locus and Bode plot of the transfer functions. The validity of the proposed control algorithm and design parameters has been verified through the PSiM simulation and experimental results.

A Practical Tuning Method of Dual-Input PSS and its Application to Large Power System (다중-입력 PSS의 실제적인 튜닝 방법과 대형 전력 시스템에의 적용)

  • Kim, Dong-Joon;Moon, Young-Hwan;Hur, Jin;Shin, Jeong-Hoon;Kim, Tae-Kyun;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.362-370
    • /
    • 2002
  • This paper describes the practical tuning method of dual-input PSS and its application to Muju P/P #2 with Proto PSS, which is based on DSP technology and uses both frequency and power. First, the model parameters of generator system used in this paper have been derived from the generator characteristic testing. Then, in the selection of PSS parameters, the Bode plot is plotted in order to tune the PSS's time constants which are able to compensate the phase lagging due to generator and excitation system. In addition, the eigenvalue analysis is also performed for determining a reliable PSS gain, $K_{s}$. Finally, the transient stability program has been utilized to verify the safe operation of Proto PSS against the predictable disturbances such as the AVR-step test and generator unloading test. In on-site test, the simulated results have been identically duplicated by implementing AVR step test in Muju P/P #2 with Proto PSS, which has the previously designed PSS parameters.s.

Damping for Wind Turbine Electrically Excited Synchronous Generators

  • Tianyu, Wang;Guojie, Li;Yu, Zhang;Chen, Fang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.801-809
    • /
    • 2016
  • The electrically excited synchronous generator (EESG) is applied in wind turbine systems recently. In an EESG control system, electrical torque is affected by stator flux and rotor current. So the control system is more complicated than that of the permanent-magnet synchronous generator (PMSG). Thus, the higher demanding of the control system is required especially in case of wind turbine mechanical resonance. In this paper, the mechanism of rotor speed resonant phenomenon is introduced from the viewpoint of mechanics firstly, and the characteristics of an effective damping torque are illustrated through system eigenvalues analysis. Considering the variables are tightly coupled, the four-order small signal equation for torque is derived considering stator and rotor control systems with regulators, and the bode plot of the closed loop transfer function is analyzed. According to the four-order mathematical equation, the stator flux, stator current, and electrical torque responses are derived by torque reference step and ramp in MATLAB from a pure mathematical deduction, which is identical with the responses in PSCAD/EMTDC simulation results. At last, the simulation studies are carried out in PSCAD software package to verify the resonant damping control strategy used in the EESG wind turbine system.

A Study on Corrosion Resistance Characteristics of PVD Cr-N Coated Steels by Electrochemical Method

  • Ahn, SeungHo;Yoo, JiHong;Choi, YoonSeok;Kim, JungGu;Han, JeonGun
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.289-295
    • /
    • 2003
  • The corrosion behavior of Cr-N coated steels with different phases (${\alpha}-Cr$, CrN and $Cr_2N$) deposited by cathodic arc deposition on Hl3 steel was investigated in 3.5% NaCl solution at ambient temperature. Potentiodynamic polarization test, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were the techniques applied to characterize the corrosion behavior. It was found that the CrN coating had a lower current density from potentiodynamic polarization test than others. The porosity, corresponding to the ratio of the polarization resistance of the uncoated and the coated substrate, was higher in the $Cr_2N$ coating than in the other Cr-N coated steels. EIS measurements showed, for the most of Cr-N coated steels, that the Bode plot presented two time constants. Also, the $Cr_2N$ coating represents the characteristic of Warburg behavior after 72hr of immersion. The coating morphologies were examined in planar view and cross-section by SEM analyses and the results were compared with those of the electrochemical measurement. The CrN coating had a dense, columnar grain-sized microstructure with minor intergranular porosity. From the above results, the CrN coating provided a better corrosion protection than the other Cr-N coated steels.