• Title/Summary/Keyword: Bm46

Search Result 77, Processing Time 0.027 seconds

Channel Model and Wireless Link Performance Analysis for Short-Range Wireless Communication Applications in the Terahertz Frequency (테라헤르츠 대역 주파수에서 근거리 무선 통신 응용을 위한 채널 모델 및 무선 링크 성능 분석)

  • Chung, Tae-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.868-882
    • /
    • 2009
  • In this paper, channel model and wireless link performance analysis for the short-range wireless communication system applications in the terahertz frequency which is currently interested in many countries will be described. In order to realize high data rates above 10 Gbps, the more wide bandwidths will be required than the currently available bandwidths of millimeter-wave frequencies, therefore, the carrier frequencies will be pushed to THz range to obtain larger bandwidths. From the THz atmospheric propagation characteristics based on ITU-R P.676-7, the available bandwidths were calculated to be 68, 48 and 45 GHz at the center frequencies of 220, 300 and 350 GHz, respectively. With these larger bandwidths, it was shown from the simulation that higher data rate above 10 Gbps can be achieved using lower order modulation schemes which have spectral efficiency of below 1. The indoor propagation delay spread characteristics were analyzed using a simplified PDP model with respect to building materials. The RMS delay spread was calculated to be 9.23 ns in a room size of $6\;m(L){\times}5\;m(W){\times}2.5\;m(H)$ for the concrete plaster with TE polarization, which is a similar result of below 10 ns from the Ray-Tracing simulation in the reference paper. The indoor wireless link performance analysis results showed that receiver sensitivity was $-56{\sim}-46\;dBm$ over bandwidth of $5{\sim}50\;GHz$ and antenna gain was calculated to be $26.6{\sim}31.6\;dBi$ at link distance of 10m under the BPSK modulation scheme. The maximum achievable data rates were estimated to be 30, 16 and 12 Gbps at the carrier frequencies of 220, 300 and 350 GHz, respectively, under the A WGN and LOS conditions, where it was assumed that the output power of the transmitter is -15 dBm and link distance of 1 m with BER of $10^{-12}$. If the output power of transmitter is increased, the more higher data rate can be achieved than the above results.

Effect of Bombyx mori, Antheraea Yamamai and Antheraea pernyi Silk Protein in Skin Fibroblast Cell Proliferation After Injury (피부세포 증식에 관여하는 실크단백질 탐색)

  • Han, Sang-Mi;Lee, Kwang-Gill;Yeo, Joo-Hong;Kweon, Hae-Yong;Woo, Soon-Ok;Baek, Ha-Ju;Park, Kwan-Kyu
    • Journal of Sericultural and Entomological Science
    • /
    • v.46 no.2
    • /
    • pp.72-76
    • /
    • 2004
  • We have studied the effect of silk proteins to the cell proliferation of human skin fibroblast cells (CCD-986sk) after injury. Silk proteins were extracted treatment with enzyme or NaOH solution from raw silk and culled-cocoon shell of Bombyx mori, Antheraea yamamai and A. pernyi. The cell proliferation after in vitro injury are increased in treatment by Bombyx mori (BM-1,2), Antheraea yamami (AY-1,2) and A. pernyi (AP-1,2). The silk protein fractions-treated cells exhibited proliferation in a dose dependent between $0.1\;{\mu}g/ml$ and $10\;{\mu}g/ml$. But, the macrophage, RAW 264. 7 cell viability was unaffected by the silk protein fractions by MTT assay. The molecular weights of the silk protein fractions were from 300-600 to 900-1500. These results results that the silk protein fractions may function through skin fibroblast proliferation.

Psychometric Validation of the Bahasa Malaysia Version of the EORTC QLQ-CR29

  • Magaji, Bello Arkilla;Moy, Foong Ming;Roslani, April Camilla;Law, Chee Wei;Raduan, Farhana;Sagap, Ismail
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8101-8105
    • /
    • 2016
  • Background: This study examined the psychometric properties of the Bahasa Malaysia (BM) version of the European Organization for Research and Treatment of Cancer (EORTC) Colorectal Cancer-specific Quality Of Life Questionnaire (QLQ-CR29). Materials and Methods: We studied 93 patients recruited from University Malaya and Universiti Kebangsaan Medical Centers, Kuala Lumpur, Malaysia using a self-administered method. Tools included QLQ-C30, QLQ-CR29 and Karnofsky Performance Scales (KPS). Statistical analyses included Cronbach's alpha, test-retest correlations, multi-traits scaling and known-groups comparisons. A p vaue ${\leq}0.05$ was considered significant. Results: The internal consistency coefficients for body image, urinary frequency, blood and mucus and stool frequency scales were acceptable (Cronbach's alpha ${\alpha}{\geq}0.65$). However, the coefficients were low for the blood and mucus and stool frequency scales in patients with a stoma bag (${\alpha}=0.46$). Test-retest correlation coefficients were moderate to high (range: r = 0.51 to 1.00) for most of the scales except anxiety, urinary frequency, buttock pain, hair loss, stoma care related problems, and dyspareunia (r ${\leq}0.49$). Convergent and discriminant validities were achieved in all scales. Patients with a stoma reported significantly higher symptoms of blood and mucus in the stool, flatulence, faecal incontinence, sore skin, and embarrassment due to the frequent need to change the stoma bag (p < 0.05) compared to patients without stoma. None of the scales distinguished between patients based on the KPS scores. There were no overlaps between scales in the QLQ-C30 and QLQ-CR29 (r < 0.40). Conclusions: the BM version of the QLQ-CR29 indicated acceptable psychometric properties in most of the scales similar to original validation study. This questionnaire could be used to complement the QLQ-C30 in assessing HRQOL among BM speaking population with colorectal cancer.

Gamma Knife Radiosurgery for Brain Metastases from Breast Cancer

  • Jo, Kyung Il;Im, Young-Hyuck;Kong, Doo Sik;Seol, Ho Jun;Nam, Do-Hyun;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.5
    • /
    • pp.399-404
    • /
    • 2013
  • Objective : The authors conducted a retrospective cohort study to determine prognostic factors and treatment outcomes of brain metastases (BM) from breast cancer (BC) after Gamma Knife radiosurgery (GKS). Methods : Pathologic and clinical features, and outcomes were analyzed in a cohort of 62 patients with BM from BC treated by GKS. The Kaplan- Meier method, the log-rank test, and Cox's proportional hazards model were used to assess prognostic factors. Results : Median survival after GKS was 73.0 weeks (95% confidence interval, 46.0-100.1). HER2+ [hazard ratio (HR) 0.441; p=0.045], Karnofsky performance scale (KPS) ${\geq}70$ (RR 0.416; p=0.050) and systemic chemotherapy after GKS (RR 0.282; p=0.001) were found to be a favorable prognostic factor of overall survival. Actuarial local control (LC) rate were $89.5{\pm}4.5%$ and $70.5{\pm}6.9%$ at 6 and 12 months after GKS, respectively. No prognostic factors were found to affect LC rate. Uni- and multivariate analysis revealed that the distant control (DC) rate was higher in patients with; a small number (${\leq}3$) of metastasis (HR 0.300; p=0.045), no known extracranial metastasis (p=0.013, log-rank test), or the HER2+ subtype (HR 0.267; p=0.027). Additional whole brain radiation therapy and metastasis volume were not found to be significantly associated with LC, DC, or overall survival. Conclusion : The treatment outcomes of patients with newly diagnosed BM from BC treated with GKS could be affected primarily by intrinsic subtype, KPS, and systemic chemotherapy. Therapeutic strategy and prognosis scoring system should be individualized based on considerations of intrinsic subtype in addition to traditionally known parameters related to stereotactic radiosurgery.

4-Channel 2.5-Gb/s/ch CMOS Optical Receiver Array for Active Optical HDMI Cables (액티브 광케이블용 4-채널 2.5-Gb/s/ch CMOS 광 수신기 어레이)

  • Lee, Jin-Ju;Shin, Ji-Hye;Park, Sung-Min
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.22-26
    • /
    • 2012
  • This paper introduces a 2.5-Gb/s optical receiver implemented in a standard 1P4M 0.18um CMOS technology for the applications of active optical HDMI cables. The optical receiver consists of a differential transimpedance amplifier(TIA), a five-stage differential limiting amplifier(LA), and an output buffer. The TIA exploits the inverter input configuration with a resistive feedback for low noise and power consumption. It is cascaded by an additional differential amplifier and a DC-balanced buffer to facilitate the following LA design. The LA consists of five gain cells, an output buffer, and an offset cancellation circuit. The proposed optical receiver demonstrates $91dB{\Omega}$ transimpedance gain, 1.55 GHz bandwidth even with the large photodiode capacitance of 320 fF, 16 pA/sqrt(Hz) average noise current spectral density within the bandwidth (corresponding to the optical sensitivity of -21.6 dBm for $10^{-12}$ BER), and 40 mW power dissipation from a single 1.8-V supply. Test chips occupy the area of $1.35{\times}2.46mm^2$ including pads. The optically measured eye-diagrams confirms wide and clear eye-openings for 2.5-Gb/s operations.

V-band MIMIC Quadruple Subharmonic Mixer Using Cascode Harmonic Generator (Cascode 하모닉 발생기를 이용한 V-band MIMIC Quadruple Subharmonic 믹서)

  • An Dan;Lee Mun Kyo;Jin Jin Man;Go Du Hyun;Lee Sang Jin;Kim Sung Chan;Chae Yeon Sik;Park Hyung Moo;Shin Dong Hoon;Rhee Jin Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.5 s.335
    • /
    • pp.55-60
    • /
    • 2005
  • A V-band MIMIC quadruple subharmonic mixer is reported in this paper. The cascode harmonic generator is proposed for a high conversion gain. The proposed cascode harmonic generator is shown with a 4-th harmonic output characteristic that represents an average of 2.9 dB and a maximum of 4 dB higher than the conventional multiplier. The measured result of the subharmonic mixer has a conversion gain of 3_4 dB which a good conversion gain at a LO power of 13 dBm. Isolations of LO-to-IF and LO-to-RF were obtained -53.6 dB and -46.2 dB, respectively. The conversion gain of the subharmonic mixer in this study has a higher conversion gain compared with some other reports in millimeter-wave range.

A Study on Iris Image Restoration Based on Focus Value of Iris Image (홍채 영상 초점 값에 기반한 홍채 영상 복원 연구)

  • Kang Byung-Jun;Park Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.2 s.308
    • /
    • pp.30-39
    • /
    • 2006
  • Iris recognition is that identifies a user based on the unique iris texture patterns which has the functionalities of dilating or contracting pupil region. Iris recognition systems extract the iris pattern in iris image captured by iris recognition camera. Therefore performance of iris recognition is affected by the quality of iris image which includes iris pattern. If iris image is blurred, iris pattern is transformed. It causes FRR(False Rejection Error) to be increased. Optical defocusing is the main factor to make blurred iris images. In conventional iris recognition camera, they use two kinds of focusing methods such as lilted and auto-focusing method. In case of fixed focusing method, the users should repeatedly align their eyes in DOF(Depth of Field), while the iris recognition system acquires good focused is image. Therefore it can give much inconvenience to the users. In case of auto-focusing method, the iris recognition camera moves focus lens with auto-focusing algorithm for capturing the best focused image. However, that needs additional H/W equipment such as distance measuring sensor between users and camera lens, and motor to move focus lens. Therefore the size and cost of iris recognition camera are increased and this kind of camera cannot be used for small sized mobile device. To overcome those problems, we propose method to increase DOF by iris image restoration algorithm based on focus value of iris image. When we tested our proposed algorithm with BM-ET100 made by Panasonic, we could increase operation range from 48-53cm to 46-56cm.

Asymmetric Saturated 3-Stage Doherty Power Amplifier Using Envelope Tracking Technique for Improved Efficiency (효율 향상을 위해 포락선 추적 기술을 이용한 비대칭 포화 3-Stage 도허터 전력 증폭기)

  • Kim, Il-Du;Jee, Seung-Hoon;Moon, Jung-Hwan;Son, Jung-Hwan;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.813-822
    • /
    • 2009
  • We have investigated operation of a 1:2:2 asymmetric 3-stage Doherty PA(Power Amplifier) and implemented using the Freescale's 4 W, 10 W PEP LDMOSFETS at 1 GHz. By employing the three peak efficiency characteristics, compared to the two peak N-way Doherty PA, the asymmetric 3-stage Doherty can overcome the serious efficiency degradation along the backed-off output power region and maximize the average efficiency for the modulation signal. To maximize the efficiency characteristic, the inverse class F PA has been designed as carrier and peaking amplifiers. Furthermore, to extract the proper load modulation operation, the adaptive gate bias control signal has been applied to the two peaking PAs based on the envelope tracking technique. For the 802.16e Mobile WiMAX(World Interoperability for Microwave Access) signal with 8.5 dB PAPR(Peak to Average Power Ratio), the proposed Doherty PA has shown 55.46 % of high efficiency at an average output power of 36.85 dBm while maintaining the -37.23 dB of excellent RCE(Relative Constellation Error) characteristic. This is the first time demonstration of applying the saturated PA and adaptive gate bias control technique to the asymmetric 3-stage Doherty PA for the highly efficient transmitter of the base-station application.

Design of a LTCC Front End Module with Power Detecting Function (전력 검출 기능을 포함하는 LTCC 프런트 엔드 모듈 설계)

  • Hwang, Mun-Su;Koo, Jae-Jin;Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal;Yang, Gyu-Yeol;Kim, Jun-Chul;Kim, Dong-Su;Park, Ung-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.844-853
    • /
    • 2008
  • This paper describes the design of a FEM(Front End Module) having power detection function for mobile handset application. The designed FEM consists of a MMIC(Monolithic Microwave Integrated Circuits) power amplifier chip, SAW Tx filter and duplexer, diode power detector and stripline matching circuit. An LTCC(Low Temperature Co-fired Ceramics) technology is adopted for miniaturized FEM. The frequency band is $824{\sim}869$ MHz which is the uplink Tx band of the CDMA mobile system. The size of designed FEM is $7.0{\times}5.5{\times}1.5\;mm^3$, which is an ultra-small size even though the power detector circuit is included. All sub-components of FEM have been developed and measured in advance before being integrated into FEM. The measured output power and gain are 27 dBm and 27 dB, respectively. In addition, the measured ACPR characteristics are 46.59 dBc and 55.5 dBc at 885 kHz and 1.98 MHz offset, respectively.

Immunomodulatory Effects of an Extract from Pinus koraiensis Cone Peel in LP-BM5 Murine Leukemia Viruses-Induced Murine Acquired Immune Deficiency Syndrome (면역 결핍 동물모델에서 잣피 추출물의 면역조절 효과)

  • Kim, Seong Pil;Kwon, Han Ol;Ha, Yejin;Heo, Seok Hyun;Lee, Jeongmin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1027-1034
    • /
    • 2017
  • The immune system is a complex process within the body that protects against disease. Recently, many studies have attempted to discover immunomodulative compounds from natural sources. Pinus koraiensis (PK) cone shell is a by-product of PK. One of the major compounds of PK cone shell is dehydroabietic acid, which has bioactivity, including antiulcer and anti-inflammatory activities. Therefore, this study was performed to examine the immunomodulative effects of PK cone shell. The immunomodulatory effects of PK cone shell extracted with 20% ethanol (EtOH) in vivo were examined initially by measuring the natural killer (NK) cell activity, phagocytic activity, Th1/Th2 cytokines release, serum immunoglobulin, and T/B cell proliferation. The NK cell activity and phagocytic activity were increased significantly by a treatment with a 20% EtOH extract of PK cone shell. Th1 type cytokine and T cell proliferation increased and Th2 type cytokine, B cell proliferation and serum immunoglobulin A, G, and E decreased after a treatment with PK cone shell extract. The 20% EtOH extract of the PK cone shell normalized the unbalanced production of Th1/Th2 type cytokine. This suggests that a 20% EtOH extract of PK cone shell has great potential as a health food.