• 제목/요약/키워드: Blower Control

검색결과 107건 처리시간 0.024초

PWM 제어기를 이용한 브로워용 인버터 (An Inverter for Blower by using PWM controller)

  • 라병훈;김성준;강태경;고강훈;이현우;김광태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.181-183
    • /
    • 2004
  • Conventional VVVF control voltage-fed inverter of blower induction motor has advantage that very speedy response characteristics for air-harmonic. But there have bad power factor on input orient have its large volume and high error ratio over 80%. And there are very expensive by reason of using the capacitor input rectifier. In this paper, It could make the smoothing capacitor-less inverter for air-blower motor by using the instantaneous compensation PWM controller. This inverter system has small volume and value compare with the conventional VVVF control inverter for blower induction motor for air-harmonic equipment.

  • PDF

틸팅열차 주변압기 냉각시스템의 동적모델 (Effective Dynamic Models of a Cooling System for the Main Transformer in a Tilting Train)

  • 한도영;노희전;원재영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.22-29
    • /
    • 2008
  • In order to improve the efficiency of a main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of optimal control algorithms of a cooling system, mathematical models of a main transformer cooling system were developed. These include dynamic models of a main transformer, an oil pump, an oil cooler, a blower, and a pipe. Control algorithms for a blower and an oil pump were selected in order to identify the effectiveness of dynamic models. A simulation program was developed by using the developed dynamic models and the selected control algorithms. Simulation results showed good predictions of dynamic behaviors of a main transformer cooling system. Therefore, dynamic models, which were developed in this study, may be effectively used to develop control algorithms of a main transformer cooling system.

  • PDF

오수/합병정화조의 배출물 제어시스템 연구 (The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;김건호;오지영;임총규;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 추계학술대회
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구 (The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;박윤규;강경식
    • 대한안전경영과학회지
    • /
    • 제3권4호
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

V/F제어를 이용한 송풍기의 일정한 공기압제어 (A Constant Air Volume Rate Control of Blower Using V/F Control)

  • 정종호;문제연;윤서진;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.100-102
    • /
    • 1998
  • This paper presents technique to control blower at constant air volume rate using V/F Control. Especially, this control method have not pressure sensors to measure because of using torque-speed relation based on the fan laws. Therefore, this technique is very simple and practical.

  • PDF

UPS 기능을 갖는 A/C Blower용 인버터 시스템 개발 (Development of the Inverter System with UPS Function for the Air-Conditioning Blower)

  • 임승범;이윤하;목형수;지준근
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.302-308
    • /
    • 2011
  • 현재 철도 차량용 공조 시스템은 3상 AC 380V를 입력으로 받아 온/오프 제어만 하고 있어 효율 저감 및 소음 등의 문제점을 가지고 있으며 AC 전원 공급이 차단될 경우 blower 동작이 멈추는 문제점을 가지고 있다. 본 논문에서는 UPS 기능을 갖는 A/C blower용 인버터 시스템을 제안한다. 제안한 인버터 시스템은 입력으로 AC 전원과 DC 전원을 받아서 blower 구동용 유도전동기의 V/F 제어를 하며, CAN통신을 이용하여 속도, 모드 및 Soft-Start 시간 등을 제어한다. 또한 CAN 통신 고장시에는 정비용으로 RS-232통신을 이용해서도 제어할 수 있고 조작자가 직접 하드웨어적으로 제어할 수도 있어 기존의 문제점을 보완할 수 있다. 시뮬레이션과 실험을 통해 제안한 인버터 시스템의 유용성을 입증한다.

하수처리장의 효율적인 Blower Control Logic 개발을 위한 유입수질 기반 공기공급량 적용 연구 (Application of the Proper Air Supply Amount Based on the Influent Water Quality for the Development of Efficient Blower Control Logic in Sewage Treatment Plants)

  • 여우석;김종규
    • 대한토목학회논문집
    • /
    • 제42권4호
    • /
    • pp.493-499
    • /
    • 2022
  • 하수처리장의 방류수 수질기준이 강화되고 있으며, 이에 따라 하수처리장 시설도 고도화되고 있다. 또한 하수처리장의 방류수질은 높은 수준으로 유지되어야 하며, 이에 따라 효율적인 하수처리장 운영이 매우 중요한 이슈로 대두되고 있다. 본 연구에서는 하수처리장의 Blower Control Loigc 개발을 위해, 하수도 시설기준의 기본 송풍량 산정 방식을 기반으로 유입수질에 따른 필요 산소량 및 송풍량을 산정하였다. 본 연구를 통해 A 하수처리장의 실제 4월 수질 데이터를 적용하여 송풍량을 산정한 결과, 평균적으로 약 12 %의 송풍량이 절감이 될 수 있다는 것을 확인하였다. 본 연구에서 산정한 결과에 따라 Blower Control Logic을 개발하여 실제 하수처리장에 적용하게 된다면, 유입수질을 기반으로 송풍량 제어가 가능함에 따라 운전자의 경험에 의존하고 있는 기존의 하수처리 운영방식에서 벗어나 하수처리장 자율제어가 가능할 것으로 판단된다. 또한, 송풍량 및 전력비 절감이 이루어진 효율적인 하수처리장 운영을 기대 할 수 있으며, 이를 통해 불필요한 에너지 및 탄소 절감에 기여할 수 있을 것이라고 판단된다.

열진공 챔버용 폐회로 열제어시스템 설계 및 성능평가 (Design and Performance Test of a Closed Loop Thermal Control System for Thermal Vacuum Chamber)

  • 서희준;조혁진;박성욱;문귀원;정상헌;허환일
    • 한국항공우주학회지
    • /
    • 제44권1호
    • /
    • pp.88-97
    • /
    • 2016
  • 폐회로 열제어 시스템은 열진공 챔버의 온도를 $-150^{\circ}C{\sim}120^{\circ}C$와 같은 온도 조건으로 모사하기 위한 시스템으로, 극저온 블로워, 슈라우드, 히터, 극저온 밸브 등으로 구성된다. 본 연구는 우주 열환경 모사를 위한 폐회로 열제어 시스템의 설계 요소 정의 및 제어 변수별 실험 결과 등을 포함하고 있다. 폐회로 열제어 시스템 설계를 위해 설계 요소인 블로워 용량, 슈라우드 재질, 형태에 따른 특성 등의 분석을 수행 하였다. 폐회로 열제어 시스템의 극저온 블로워 필요 유량은 에너지 평형 방정식에 의해 결정되며, 제어는 작동 유체의 밀도 제어를 통해 제어된다. 밀도, 회전수와 같은 제어 변수별 실험을 통해 슈라우드 온도 분포 균질도 및 균일도를 측정하여 요구된 폐회로 열제어 시스템의 성능을 확인 하였다.

타워형 에어컨 송풍기 소음의 능동제어 (Active Control of Noise from Fan Blowers in Tower-type Air Conditioners)

  • 류경완;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.87-93
    • /
    • 2017
  • This paper investigates active noise control of tower-type air conditioners using the filtered-x least mean square (FXLMS) algorithm to reduce fan blower noise transmission. Firstly, the main components required for the active control system including the error sensor, the control speaker and the reference sensors are selected. Since the noise could significantly reduce if the reference signal includes every frequency response information, a various reference signals from accelerometers and a microphone are used. Secondly, the controller based on the FXLMS algorithm with a single-channel reference signal is implemented. Then, the control performance is examined experimentally for the different reference signals. It is found that the accelerometer signal well possesses the motor vibration related noise and a microphone signal could includes global noise. When using the reference signal with a microphone located near the motor and the fan blower, the active control system reduces the noise globally, except for several peaks.

열진공 챔버용 극저온 블로워 설계 및 성능평가 (Design and Performance Tests of a Cryogenic Blower for a Thermal Vacuum Chamber)

  • 서희준;조혁진;박성욱;문귀원;허환일
    • 한국항공우주학회지
    • /
    • 제43권11호
    • /
    • pp.1008-1015
    • /
    • 2015
  • 위성체의 지상 검증 시험에는 열진공 챔버가 사용되며, 열제어 시스템은 열진공 챔버의 핵심이라고 할 수 있다. 특히, 기체 질소를 이용한 폐회로 열제어 시스템의 성능은 극저온 블로워의 성능에 의해 결정된다. 본 연구의 최종 목표는 설계 요구조건 $-150^{\circ}C{\sim}150^{\circ}C$의 온도 조건, 유량 150 CFM, 0.5 bara 이상의 차압을 갖는 극저온 블로워를 개발하는 것으로, 1차원 해석툴 및 CFD를 이용한 성능해석을 통해 임펠러를 설계 하였으며, 구동부와 유체부의 열전달 방지를 위한 열장벽, 모터의 과열 방지를 위한 냉각 시스템 등이 설계되었다. 표준대기상태에서 실험을 통해 성능을 검증하였으며, 최종적으로 열진공 챔버내에 설치하여 운영 조건에서 극저온 블로워의 성능을 확인하였다.