• Title/Summary/Keyword: Blood vessel image

Search Result 89, Processing Time 0.035 seconds

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

A dual path encoder-decoder network for placental vessel segmentation in fetoscopic surgery

  • Yunbo Rao;Tian Tan;Shaoning Zeng;Zhanglin Chen;Jihong Sun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.1
    • /
    • pp.15-29
    • /
    • 2024
  • A fetoscope is an optical endoscope, which is often applied in fetoscopic laser photocoagulation to treat twin-to-twin transfusion syndrome. In an operation, the clinician needs to observe the abnormal placental vessels through the endoscope, so as to guide the operation. However, low-quality imaging and narrow field of view of the fetoscope increase the difficulty of the operation. Introducing an accurate placental vessel segmentation of fetoscopic images can assist the fetoscopic laser photocoagulation and help identify the abnormal vessels. This study proposes a method to solve the above problems. A novel encoder-decoder network with a dual-path structure is proposed to segment the placental vessels in fetoscopic images. In particular, we introduce a channel attention mechanism and a continuous convolution structure to obtain multi-scale features with their weights. Moreover, a switching connection is inserted between the corresponding blocks of the two paths to strengthen their relationship. According to the results of a set of blood vessel segmentation experiments conducted on a public fetoscopic image dataset, our method has achieved higher scores than the current mainstream segmentation methods, raising the dice similarity coefficient, intersection over union, and pixel accuracy by 5.80%, 8.39% and 0.62%, respectively.

Treatment of the Herniated Nucleus Pulposus Syndrome by Chemonucleolysis with Chymopapain

  • Dabezies, Eugene J.
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.111-120
    • /
    • 1984
  • A new restoration method of chest X-ray image (dual project filter) was proposed to improve SNR (signal to noise ratio) characteristics. In this method, a priori information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lungregion, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

In vivo Imaging Flow Cytometer (세포 이미징 기능을 겸비한 생체 유세포 분석기)

  • Lee, Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.9-11
    • /
    • 2007
  • We introduce an in vivo imaging flow cytometer, which provides fluorescence images simultaneously with quantitative information on the cell population of interest in a live animal. As fluorescent cells pass through the slit of light focused across a blood vessel, the excited fluorescence is confocally detected. This cell signal triggers a strobe beam and a high sensitivity CCD camera that captures a snap-shot image of the cell as it moves down-stream from the slit. We demonstrate that the majority of signal peaks detected in the in vivo flow cytometer arise from individual cells. The instrument's capability to image circulating T cells and measure their speed in the blood vessel in real time in vivo is demonstrated. The cell signal irradiance variation, clustering percentage, and potential applications in biology and medicine are discussed.

Fabrication of a Staircase Coil with Improved SNR and Image Uniformity by Structural Changes of a Conventional Birdcage Coil at 1.5T MRI

  • Ryang, Kyung-Seung;Shin, Yong-Jin
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.7 no.1
    • /
    • pp.25-36
    • /
    • 2003
  • The performance of radio frequency (RF) coils, used in MRI units, is determined by the image uniformity and the signal-to-noise ratio (SNR). Birdcage and surface coils are commonly used. A birdcage coil provides a good image uniformity while a surface coil produces a high SNR. In this study, therefore, a staircase coil was designed from a standard version of a birdcage coil, with some structural changes to increase SNR while maintaining image uniformity. In phantom experiments, the improvement of the image to uniformity and the SNR increase of the staircase coil compared with the values for the birdcage coil were about 3.5% and 35%, respectively. In clinical experiment, the SNR increase of the staircase coil, compared with the value for the birdcage coil was about 40% in bone, muscle and blood-vessel tissues. These results show that the performance of the staircase coil was very improved over the standard birdcage coil in terms of SNR, and that image uniformity was maintained. Therefore, the staircase coil designed by this study should be useful in experimental and clinical l.5T MRI systems, and this coil offers an alternative method of quadrature detection.

  • PDF

Laser Speckle Imaging Using Laser Speckle Endoscope (레이저 스펙클 내시경을 이용한 미세혈관 영상화 기법)

  • Jin, Ho-Young;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.91-96
    • /
    • 2010
  • A laser speckle is a random pattern that has a granular appearance produced by reflected light when a coherent laser illuminates an irregular course surface. Laser speckle system has many advantages. It can detect some animals functional parts. Moreover, it relatively consists of simple and in-expensive system. It is very important that detecting micro-vessels through image processed image. Current study is to improve image quality through variable image processing method. But this paper made laser speckle endoscope for miniaturization and commercialization laser speckle system. We had endoscope test through goldfish's tail. We will compare the processed speckle image and halogen image.

A Study on the Detection of Pulmonary Blood Vessel Using Pyramid Images and Fuzzy Theory (피라미드 영상과 퍼지이론을 이용한 폐부 혈관의 검출에 관한 연구)

  • Hwang, Jun-Hyun;Park, Kwang-Suk;Min, Byoung-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.99-106
    • /
    • 1991
  • For the automatic detection of pulmonary blood vessels, a new algorithm is proposed using the fact that human recognizes a pattern orderly according to their size. This method simulates the human recognition process by the pyramid images. For the detection of vessels using multilevel image, large and wtde ones are detected from the most compressed level, followed by the detection of small and narrow ones from the less compressed images with FCM(fuzzy c means) clustering algorithm which classifies similar data into a group. As the proposed algorithm detects blood vessels orderly according to their size, there is no need to consider the variation of parameters and the branch points which should be considered in other detection algirithms. In the detection of patterns whose size changes successively like pulmonary blood vessels, this proposed algorithm can be properly applied

  • PDF

Effects of stenotic severity on the flow structure in a circular channel under a pulsatile flow

  • Kim, Kyung-Won;Cheema, Taqi-Ahmad;Park, Cheol-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.140-146
    • /
    • 2014
  • Stenosis is the drastic reduction in the cross-sectional area of blood vessel caused by accumulations of cholesterol. It affects the blood flow property and structure from the fluid dynamic point of view. To understand the flow phenomenon more clearly, a particle image velocimetry method is used and the fluid dynamic characteristics in a circular channel containing stenosis structure is investigated experimentally in this study. Different stenotic-structured models made of acrylic material are subjected to a pulsatile flow generated by an in-house designed pulsatile pump. The inner diameter of the tube inlet is 20 mm and the length of reduced area for stenosis ranges between 35mm and 40mm. It is circulated continuously through a circular channel by the pump system. Pressure is measured at four different sections during systolic and diastolic phase changes. The phase-averaged velocity field distribution shows a recirculation regime after the stenotic structure. The effects of the stenotic obstructions are found to be more severe when the aspect ratio is varied.

Virtual Angioscopy for Diagnosis of Carotid Artery Stenosis (경동맥 협착증 진단을 위한 가상혈관경)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.9
    • /
    • pp.821-828
    • /
    • 2003
  • The virtual angioscopy was implemented using MR angiography image of carotid artery Inside of the carotid artery is one of the body region not accessible by real optical endoscopy but can be visualized with virtual endoscopy. In order to determine the navigation path, we segmented the common carotid artery and internal carotid artery from the MR angiography image. We used the coordinates as a navigation path for virtual camera that were calculated from medial axis transformation. We used the perspective projection and marching cube algorithm to render the surface from volumetric MRA image data. A stroke occurs when brain cells die because of decreased blood flow to the brain. The carotid artery is the primary blood vessel that supplies the blood flow to the brain. Therefore, the carotid artery stenosis is the primary reason of stroke. The virtual angioscopy is highly recommended as a diagnosis tool with which the specific Place of stenosis can be identified and the degree of stenosis can be measured qualitatively. Also, the virtual angioscopy can be used as an education and training tool for endoscopist and radiologist.