• Title/Summary/Keyword: Block length

Search Result 680, Processing Time 0.028 seconds

A Comparative Research on the Drafting Method of the Basic Patterns for Women (여성용 원형 제도법에 관한 비교 연구)

  • Kim, Jeong-Hee;Kim, Hee-Jin;Cho, Jae-Hee;Lim, Kyoung-Hwa;Yi, Kyong-Hwa
    • Korean Journal of Human Ecology
    • /
    • v.10 no.4
    • /
    • pp.379-390
    • /
    • 2001
  • The purpose of this study is to investigate the fitness according to drafting method of the block patterns for women in Korea. The major findings of this study are as follows: 1. According to comparative analysis of required measurements, two measurements of back length and bust girth are used in Proportional Drafting Method (Munhwa). In case of Compromise Drafting Methods are used across chest, across back, bust length, bust width, full length in front, across shoulder and shoulder length in addition to back length and bust girth. The type of Armstrong as a Short Measure Drafting Method uses 10 measurements for the drafting the bodice. 2. While Esmod block pattern arid Armstrong's block pattern are the lightest in full width and other widths. Rasara block pattern is the most ample. In Lee, Myung-hee's block pattern and Lee, Hyung-sook's block pattern, amounts of drooping are decided $3{\sim}4cm$, but drooping amounts of other block patterns are decided corresponding to real measurements. While cap height in Esmod and Armstrong's sleeve patterns are directly measured Armhole length of the block pattern, cap height of other sleeve patterns are used armhole depth and cap height length as well as armhole length. 3. When analyzing to indirect measurements, Esmod block pattern shows the least different between full length of block pattern and that of body form. Munhwa block pattern and Kim, Hyosook's block pattern are mostly same to body form back length. However all of the block patterns are sheller than body form length. In case of Suh, Wansuk's block pattern, across back and across chest are same size, but other block patterns show difference between across back and across chest. Most block patterns' neck width in front and bach bodice are almost same. Front neck width is generally bigger than back neck width in some cases.

  • PDF

A Study on the Determination of the Information Block Length of mBIZ Code (mBIZ 부호의 최적 정보장 결정에 관한 연구)

  • Song, J.C.;Yoo, B.S.;Won, D.H.;Park, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.461-464
    • /
    • 1988
  • In order to use mBIZ code as the practical transmission code, the information block length have to be determined. If the information block length is short, timing information disapperance is reduced, but transmission speed is increased as the result of inserted redundancy bit. While, if the information block length is long, timing information disapperance and jitter are caused. So it is very important to determine the optimal timing information block length. Therefore, in this paper, we determined the optimal information block length using S/X endurance method.

  • PDF

A Study on the Headway bewteen Dongdaegu and Busan by block system length (폐색 구간 길이에 따른 동대구-부산간 운전 시격 연구)

  • Kim, Yong-Kyu;Yang, Doh-Chul;Kim, Jong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1292-1294
    • /
    • 2002
  • In this study, the block section length of the given area has been analyzed to improve the headway which caused by the mixed operation of high speed trains and normal trains on the electrified railway of Dongdaegu to Busan. After establishing the average length of block section and the adjustable average length of block section of Dongdaegu to Busan, it is possible to perform the headway simulation regarding the signal system based on the established length. Although high speed trains as well as low speed trains including freight trains operate together, the experimental results indicate that the modification of the block section length shows the possibility of the improvement of headway.

  • PDF

How to Avoid Graft-Tunnel Length Mismatch in Modified Transtibial Technique for Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Graft

  • Ko, Dukhwan;Kim, Hyeung-June;Oh, Seong-Hak;Kim, Byung-June;Kim, Sung-Jae
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.407-412
    • /
    • 2018
  • Background: We conducted this study to determine the optimal length of patellar and tibial bone blocks for the modified transtibial (TT) technique in anterior cruciate ligament (ACL) reconstruction using the bone-patellar tendon-bone (BPTB) graft. Methods: The current single-center, retrospective study was conducted in a total of 64 patients with an ACL tear who underwent surgery at our medical institution between March 2015 and February 2016. After harvesting the BPTB graft, we measured its length and that of the patellar tendon, patellar bone block, and tibial bone block using the arthroscopic ruler and double-checked measurements using a length gauge. Outcome measures included the length of tibial and femoral tunnels, inter-tunnel distance, length of the BPTB graft, patellar tendon, patellar bone block, and tibial bone block and graft-tunnel length mismatch. The total length of tunnels was defined as the sum of the length of the tibial tunnel, inter-tunnel distance and length of the femoral tunnel. Furthermore, the optimal length of the bone block was calculated as (the total length of tunnels - the length of the patellar tendon) / 2. We analyzed correlations of outcome measures with the height and body mass index of the patients. Results: There were 44 males (68.7%) and 20 females (31.3%) with a mean age of 31.8 years (range, 17 to 65 years). ACL reconstruction was performed on the left knee in 34 patients (53%) and on the right knee in 30 patients (47%). The optimal length of bone block was 21.7 mm (range, 19.5 to 23.5 mm). When the length of femoral tunnel was assumed as 25 mm and 30 mm, the optimal length of bone block was calculated as 19.6 mm (range, 17 to 21.5 mm) and 22.1 mm (range, 19.5 to 24 mm), respectively. On linear regression analysis, patients' height had a significant correlation with the length of tibial tunnel (p = 0.003), inter-tunnel distance (p = 0.014), and length of patellar tendon (p < 0.001). Conclusions: Our results indicate that it would be mandatory to determine the optimal length of tibial tunnel in the modified TT technique for ACL reconstruction using the BPTB graft. Further large-scale, multi-center studies are warranted to establish our results.

Design of an Area-Efficient Architecture for Block-wise MAP Turbo Decoder (면적 효율적인 구조의 블록 MAP 터보 복호기 설계)

  • Kang, Moon-Jun;Kim, Sik;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.8A
    • /
    • pp.725-732
    • /
    • 2002
  • Block-wise MAP (Maximum A posteriori) decoding algorithm for turbo-codes requires less memory than Log-MAP decoding algorithm. The ER (Bit Error Rate) performance of previous block-wise MAP decoding algorithm depend on the block length and training length. To maximize hardware utilization and perform successive decoding, the block length is set to be equal to the training length in previous MAP decoding algorithms. Simulation result on the BER performance shows that the EBR performance can be maintained with shorter blocks when training length is sufficient. This paper proposes an architecture for area efficient block-wise MAP decoder. The proposed architecture employs the decoding schema for reducing memory by using the training length, which in N times larger than block length. To efficiently handle the proposed schema, a pipelined architecture is proposed. Simulation results show that memory usage can be reduced by 30%~45% in the proposed architecture without degrading the BER performance.

Advancing the Gauge Block Interferometer and Automating the Gauge Block Calibration (게이지 블록 간섭계의 선진화 및 완전 자동화)

  • Kang Chu-Shik;Kim Jae-Wan;Suh Ho-Suhng;Lee Won-Kyu;Kim Jong-Ahn
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.547-550
    • /
    • 2005
  • Gauge blocks are the most widely used material measure in length field in industry. The gauge block interferometer, which is the gauge block measuring system, comprises Twyman-Green type interferometer optics and light sources having precisely known wavelengths. This paper describes the work done for advancing the measurement system and automating the measurement process. The advancing of the system was done mainly by exchanging the spectral lamp with the frequency stabilized lasers, and the automation of measurement was achieved by modifying the hardware and developing the automatic measuring software. As the results of this work, the contrast of interferometric fringes of gauge blocks longer than 100 mm s enhanced about 20 times, and the measurement time has reduced down to 50% by automation.

  • PDF

High Performance HIGHT Design with Extended 128-bit Data Block Length for WSN (WSN을 위한 128비트 확장된 데이터 블록을 갖는 고성능 HIGHT 설계)

  • Kim, Seong-Youl;Lee, Je-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.124-130
    • /
    • 2015
  • This paper presents a high performance HIGHT processor that can be applicable for CCM mode. In fact, HIGHT algorithm is a 64-bit block cipher. However, the proposed HIGHT extends the basic block length to 128-bit. The proposed HIGHT is operated as 128-bit block cipher and it can treat 128-bit block at once. Thus, it can be applicable for the various WSN applications that need fast and ultralight 128-bit block cipher, in particular, to be operated in CCM mode. In addition, the proposed HIGHT processor shares the common logics such as 128-bit key scheduler and control logics during encryption and decryption to reduce the area overhead caused by the extension of data block length. From the simulation results, the circuit area and power consumption of the proposed HIGHT are increases as 40% and 64% compared to the conventional 64-bit counterpart. However, the throughput of the proposed HIGHT can be up to two times as fast. Consequently, the proposed HIGHT is useful for USN and handheld devices based on battery as well as RFID tag the size of circuit is less than 5,000 gates.

IP Design of Corrected Block TEA Cipher with Variable-Length Message for Smart IoT

  • Yeo, Hyeopgoo;Sonh, Seungil;Kang, Mingoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.724-737
    • /
    • 2020
  • Corrected Block TEA(or XXTEA) is a block cipher designed to correct security weakness in the original block TEA in 1998. In this paper, XXTEA cipher hardware which can encrypt or decrypt between 64-bit and 256-bit messages using 128-bit master key is implemented. Minimum message block size is 64-bit wide and maximal message block size is 256-bit wide. The designed XXTEA can encrypt and decrypt variable-length message blocks which are some arbitrary multiple of 32 bits in message block sizes. XXTEA core of this paper is described using Verilog-HDL and downloaded on Vertex4. The operation frequency is 177MHz. The maximum throughput for 64-bit message blocks is 174Mbps and that of 256-bit message blocks is 467Mbps. The cryptographic IP of this paper is applicable as security module of the mobile areas such as smart card, internet banking, e-commerce and IoT.

On the Design of Block Lengths for Irregular LDPC Codes Based on the Maximum Variable Degree

  • Chung, Kyu-Hyuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11C
    • /
    • pp.907-910
    • /
    • 2010
  • This paper presents the design of block lengths for irregular low-density parity-check (LDPC) codes based on the maximum variable degree $d_{{\upsilon},max}$. To design a block length, the performance degradation of belief-propagation (BP) decoding performance from upper bounds on the maximum likelihood (ML) decoding performance is used as an important factor. Since for large block lengths, the performance of irregular LDPC codes is very close to the Shannon limit, we focus on moderate block lengths ($5{\times}10^2\;{\leq}\;N\;{\leq}\;4{\times}10^3$). Given degree distributions, the purpose of our paper is to find proper block lengths based on the maximum variable degree $d_{{\upsilon},max}$. We also present some simulation results which show how a block length can be optimized.

Effect of Evacuation Variables on Pressure Change in the Die Cavity (다이캐스팅 금형 공간 내의 감압도에 미치는 제 변수의 영향)

  • Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.20 no.3
    • /
    • pp.181-187
    • /
    • 2000
  • There are two types of vacuum die casting, one is known as the chill block method, and the other is the valve block method. Efficiency of the valve block method is better than the chill block method. However purchasing and maintaining cost of the former one is very high, the latter method is popular in many small and medium die casting shops. Simple evacuation system using chill vent was prepared to investigate the effect of the air pressure, hose length and chill vent type on the pressure change in die cavity in this study. The rate of evacuation was influenced by the evacuation method, chill vent condition and hose length. Evacuation time became longer and vacuum level lower when evacuating cavity via chill vent. It took a longer time to evacuate the cavity when a longer hose was used. Vacuum level in the cavity also decreased with increase in hose length.

  • PDF