• Title/Summary/Keyword: Bit-rate

Search Result 3,046, Processing Time 0.03 seconds

Effect of Water on the Lightweight Air-Mixed Soil Containing Silt Used for Road Embankment (도로성토체로 사용된 실트질 계열의 경랑기포혼합토에 대한 물의 영향)

  • Hwang, Joong-Ho;Ahn, Young-Kyun;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.23-32
    • /
    • 2010
  • This study was especially conducted to find out the characteristics of the lightweight air-mixed soil (slurry density 10 kN/$m^3$) containing silt related to water. Compression strength, permeability, and capillary height of the lightweight air-mixed soil were studied, and also to support these studies, the structure of that soil was analyzed in detail. Air bubbles of various sizes are inside the lightweight air-mixed soil, and its distribution in a location is almost constant. A numerous tiny pores are inside the air bubbles so that the lightweight air-mixed soil can be saturated with water. Porosity is also estimated through the image analysis. Peak strength of the lightweight air-mixed soil is not dependent on water, but behavior of stress-strain is affected by the water. Permeability is about $4.857{\times}10^{-6}cm/sec$, which is a little bit higher than the clay's permeability. Capillary rise occurs rapidly at the beginning of the test until the lapse of 100 minutes and then its increase rate becomes slow. The capillary rise causes the increase of the density of the lightweight air-mixed soil, and thus it is required to pay attention to this phenomenon during structure design and maintenance of the lightweight air-mixed soil.

Prevention and Overcoming Strategies for Taeoom in the Nursing Workplace: Based on the P-S-O-R Framework (간호업무 현장에서의 태움 예방 및 극복방안: P-S-O-R 프레임워크를 기반으로)

  • Eun Jin Kim;Sodam Kim;Sang-Hyeak Yoon;Sung-Byung Yang
    • Journal of Service Research and Studies
    • /
    • v.13 no.4
    • /
    • pp.70-96
    • /
    • 2023
  • Recently, the high turnover rate of nursing staff and the problems caused by increased job stress have been highlighted as social issues, and the problem of 'Taeoom' in nursing organizations has received increasing attention. Therefore, the purpose of this study is to propose a solution to the Taeoom problem, including bullying in the nursing work environment, as there is an urgent need to find a solution to prevent and overcome this problem. For this purpose, based on the S-O-R framework and previous studies, job stress and turnover intention were derived as outcome variables of Taeoom and communication competence as an antecedent factor, and a research model was constructed with the expectation that mindfulness and social support would serve as moderating variables to help overcome this problem. Data were collected through a survey of 300 nurses who had experienced Taeoom within the past year, and the hypotheses were tested using a structural equation model. The results revealed that the higher the communication competence of nurses, the less they perceived the damage of Taeoom, and that the damage caused by Taeoom leads to turnover intention through high job stress. In addition, mindfulness and social support significantly attenuated the positive effects of burnout on job stress and job stress on turnover intention, respectively. The significance of this study is that it proposed an extended P-S-O-R framework by adding a prevention stage to the existing S-O-R framework, and further tested the moderating effects of mindfulness and social support variables. It is expected that the findings of this study will provide concrete guidelines to prevent and overcome the Taeoom problem that can be applied in practice.

A 2×2 MIMO Spatial Multiplexing 5G Signal Reception in a 500 km/h High-Speed Vehicle using an Augmented Channel Matrix Generated by a Delay and Doppler Profiler

  • Suguru Kuniyoshi;Rie Saotome;Shiho Oshiro;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.10
    • /
    • pp.1-10
    • /
    • 2023
  • This paper proposes a method to extend Inter-Carrier Interference (ICI) canceling Orthogonal Frequency Division Multiplexing (OFDM) receivers for 5G mobile systems to spatial multiplexing 2×2 MIMO (Multiple Input Multiple Output) systems to support high-speed ground transportation services by linear motor cars traveling at 500 km/h. In Japan, linear-motor high-speed ground transportation service is scheduled to begin in 2027. To expand the coverage area of base stations, 5G mobile systems in high-speed moving trains will have multiple base station antennas transmitting the same downlink (DL) signal, forming an expanded cell size along the train rails. 5G terminals in a fast-moving train can cause the forward and backward antenna signals to be Doppler-shifted in opposite directions, so the receiver in the train may have trouble estimating the exact channel transfer function (CTF) for demodulation. A receiver in such high-speed train sees the transmission channel which is composed of multiple Doppler-shifted propagation paths. Then, a loss of sub-carrier orthogonality due to Doppler-spread channels causes ICI. The ICI Canceller is realized by the following three steps. First, using the Demodulation Reference Symbol (DMRS) pilot signals, it analyzes three parameters such as attenuation, relative delay, and Doppler-shift of each multi-path component. Secondly, based on the sets of three parameters, Channel Transfer Function (CTF) of sender sub-carrier number n to receiver sub-carrier number l is generated. In case of n≠l, the CTF corresponds to ICI factor. Thirdly, since ICI factor is obtained, by applying ICI reverse operation by Multi-Tap Equalizer, ICI canceling can be realized. ICI canceling performance has been simulated assuming severe channel condition such as 500 km/h, 8 path reverse Doppler Shift for QPSK, 16QAM, 64QAM and 256QAM modulations. In particular, 2×2MIMO QPSK and 16QAM modulation schemes, BER (Bit Error Rate) improvement was observed when the number of taps in the multi-tap equalizer was set to 31 or more taps, at a moving speed of 500 km/h and in an 8-pass reverse doppler shift environment.

A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results (CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구)

  • Jae-Seok An;Ji-Na Kim;Kwang-Seo Park;Eun-Bit Joo;Sang-Hyuk Yoon;Yoon-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2024
  • Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

Bulb Propagation on Nerine by Tissue Culture (조직배양에 의한 네리네 대량증식)

  • Han, Soo-Gon;Kang, Chan-Ho;Choi, In-Young;Choi, So-Ra;Lim, Hoi-Chun;Lee, Jin-Je;Oh, Nam-Ki;Choi, Jeong-Sik
    • Korean Journal of Plant Resources
    • /
    • v.21 no.2
    • /
    • pp.134-138
    • /
    • 2008
  • Nerine from south africa and its sparkling flower shape make us estimate it as a hopeful kind of cut follow. There was a few studies on Nerine in korea. We started this study to set bulb propagation methods. The propagation by tissue culture was changeable according to the growth regulators The best growth regulator combination which makes a lot of Bulblet was NAA $0{\sim}0.5$ + BA $0.5{\sim}2.0mg\;{\cdot}\;L^{-1}$ in Nerine bowdenii ‘Favourite’ and Nerine sarniens ‘Red’ respectively. The adjust culture media source for tissue culture were glucose 9% as a carbon source and ($NH_4+NO_3$) 40mM as a nitrogen source. When glucose was used as a carbon source, Bulblet were harvested a little bit low then sucrose but comparative emergence rate was so high that it is good for carbon source in nerine tissue culture. When we consist culture media as MS+BA $1.0mg\;{\cdot}\;L^{-1}$+sucose 7% + ($NH_4+NO_3$) 40mM, the produced Bulblet were reached up to 1.7 each per bulb and emergence rate was up to 100% irrespective of acclimatization period. The suitable culture explant for nerine tissue culture was scale. When scale was cultured with MS+BA $1.0mg\;{\cdot}\;L^{-1}$+sucose 7%, its propagation efficiency was 54 times greater than using growing point. A proper culture part of the scaly leaf was middle part (8 scaly leaf from outer 8th scaly leaf) when middle part was cultured the number of Bulblet were up to 1.8 each per explant.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

Development of a deep-learning based tunnel incident detection system on CCTVs (딥러닝 기반 터널 영상유고감지 시스템 개발 연구)

  • Shin, Hyu-Soung;Lee, Kyu-Beom;Yim, Min-Jin;Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.915-936
    • /
    • 2017
  • In this study, current status of Korean hazard mitigation guideline for tunnel operation is summarized. It shows that requirement for CCTV installation has been gradually stricted and needs for tunnel incident detection system in conjunction with the CCTV in tunnels have been highly increased. Despite of this, it is noticed that mathematical algorithm based incident detection system, which are commonly applied in current tunnel operation, show very low detectable rates by less than 50%. The putative major reasons seem to be (1) very weak intensity of illumination (2) dust in tunnel (3) low installation height of CCTV to about 3.5 m, etc. Therefore, an attempt in this study is made to develop an deep-learning based tunnel incident detection system, which is relatively insensitive to very poor visibility conditions. Its theoretical background is given and validating investigation are undertaken focused on the moving vehicles and person out of vehicle in tunnel, which are the official major objects to be detected. Two scenarios are set up: (1) training and prediction in the same tunnel (2) training in a tunnel and prediction in the other tunnel. From the both cases, targeted object detection in prediction mode are achieved to detectable rate to higher than 80% in case of similar time period between training and prediction but it shows a bit low detectable rate to 40% when the prediction times are far from the training time without further training taking place. However, it is believed that the AI based system would be enhanced in its predictability automatically as further training are followed with accumulated CCTV BigData without any revision or calibration of the incident detection system.

The Effect of Eating Habits and Lifestyle on the Food Intake of University Students in Daejeon (대전지역 대학생들의 식생활 실태 및 생활습관이 식품섭취에 미치는 영향)

  • 박상욱
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.14 no.1
    • /
    • pp.11-19
    • /
    • 2004
  • To investigate the effect of eating habits and lifestyle on the food intake of university students in Daejeon, 104 male students(26.75%) and 282 female students(73.75%) were surveyed about their food intake, eating habits, and lifestyle using the questionnaire. The major food served as breakfast was steamed rice(76.05%) and there was a little significant difference between male and female. The major food served as lunch was also steamed rice(73.77%) and male students ate it more than female ones. According to the survey, 41.95% of the subjects had breakfast regularly, and 24.35% seldom, which showed no significant difference between male and female. In case of lunch, the percentile of subjects(54.55%) who had regularly eaten lunch was more than that of breakfast, and there was a little significant difference between male and female. The survey said most subjects(49.22%) had eaten dinner irregularly, which rate was higher in male students. The meal skipped usually was the breakfast(24.35%), which rate was higher in female students. The reason why the subjects skipped the meal was mainly due to the lack of sufficient time for breakfast and lunch, and for dinner to the weight loss. Among the subjects, 80% said they were non-smokers; 96.44% in female students and 35.58% in male ones. In case of drinking, most subjects said they sometimes drank(67.19%) and the frequency of drinking was once or twice a month(51.99%), which showed the significant difference between male and female. In the aspects of effects of drinking and smoking on the food intake, the drinking practice after eating was shown to be the highest(55.98%); smoking generally affected the food intake, which showed the difference between male and female. Food intake during the examination period didn't show any differences to the usual one or increased a little bit, which showed a difference between male and female. Losing appetite during the examination period was shown mainly in the female students. When they felt blue or tired, the food intake decreased, which showed a significant difference between male and female was shown. When feeling good, the food intake significantly increased, which showed a significant difference between male and female. Therefore, there was a significant difference between male and female in the actual eating habits and in the aspects of food intake.

  • PDF

Evaluation on the Immunization Module of Non-chart System in Private Clinic for Development of Internet Information System of National Immunization Programme m Korea (국가 예방접종 인터넷정보시스템 개발을 위한 의원정보시스템의 예방접종 모듈 평가연구)

  • Lee, Moo-Sik;Lee, Kun-Sei;Lee, Seok-Gu;Shin, Eui-Chul;Kim, Keon-Yeop;Na, Bak-Ju;Hong, Jee-Young;Kim, Yun-Jeong;Park, Sook-Kyung;Kim, Bo-Kyung;Kwon, Yun-Hyung;Kim, Young-Taek
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.65-75
    • /
    • 2004
  • Objectives: Immunizations have been one of the most effective measures preventing from infectious diseases. It is quite important national infectious disease prevention policy to keep the immunizations rate high and monitor the immunizations rate continuously. To do this, Korean CDC introduced the National Immunization Registry Program(NIRP) which has been implementing since 2000 at the Public Health Centers(PHC). The National Immunization Registry Program will be near completed after sharing, connecting and transfering vaccination data between public and private sector. The aims of this study was to evaluate the immunization module of non-chart system in private clinic with health information system of public health center(made by POSDATA Co., LTD) and immunization registry program(made by BIT Computer Co., LTD). Methods: The analysis and survey were done by specialists in medical, health field, and health information fields from 2001. November to 2002. January. We made the analysis and recommendation about the immunization module of non-chart system in private clinic. Results and Conclusions: To make improvement on immunization module, the system will be revised on various function like receipt and registration, preliminary medical examination, reference and inquiry, registration of vaccine, print-out various sheet, function of transfer vaccination data, issue function of vaccination certification, function of reminder and recall, function of statistical calculation, and management of vaccine stock. There are needs of an accurate assessment of current immunization module on each private non-chart system. And further studies will be necessary to make it an accurate system under changing health policy related national immunization program. We hope that the result of this study may contribute to establish the National Immunization Registry Program.

  • PDF