• Title/Summary/Keyword: Biomedical Monitoring

Search Result 455, Processing Time 0.036 seconds

A Case of Natural Mycoplasmosis in Spontaneously Hypertensive Rats (Mycoplasm pulmonis에 자연 감염된 SHR 랫드)

  • Roh, In-Soon;Oh, Seung Hyun;Park, Ji Young;Choi, Kyung-Chul;Han, Jeong-Hee;Jin, Hee-Kyung;Do, Seon Gil;Suh, Jun Gyo;Oh, Yang Seok;Park, Seong-Jun;Seong, Je-Kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.579-582
    • /
    • 2001
  • Twenty one Spontaneously Hypertensive Rats(SHR) that were 4- to 21-month-old were examined histopathologically and serologically during a routine health monitoring of the rat colony. The results of the enzyme linked immunosorbent assay(ELISA) for murine pathogens demonstrated that 14 of 21 SHR rats had antibodies to Mycoplasma pulmonis. Histopathologically, the mycoplasma positive SHR rats were observed to have the typical pulmonary lesions which are characterized by the hyperplasia of the lymphoid tissue around the bronchi, bronchioles and vessels. Based on the histopathological findings and serological results, this case was diagnosed as a murine mycoplasmosis of SHR rats.

  • PDF

Epidural Space Identification Device Using Air-filled Catheter (공기도관을 사용하는 경막외강 자동탐지기구)

  • 강재환;김현식;김경아;김상태;배진호;임승운;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.9-13
    • /
    • 2003
  • An assist device was developed to identify the epidural space by continously monitoring the air-filled catheter pressure. The pressure signal appropriately amplified and filtered enabled to alarm the needle introduction into the epidural space by thresholding detection. Ten LEDs provided a visual change of catheter pressure before alarming for user convenience. Clinical trials were performed in 30 patients with 83% success rate at the first trial. When failed, the second trial was enough for successful anesthesia. The air volume introduced during each anesthesia was less than 1ml, causing side effects. Air filling of the catheter could also minimize infection possibility. Therefore, the present device guarantees safe anesthesia with user convenience.

The Effects of Microwave Irradiated on Rabbit's ICP (전자기파 조사가 실험동물의 뇌압에 미치는 영향)

  • Park, Jin-Han;Kim, Seong-Ho;Han, Dong-Ro;Bae, Jang-Ho;Kim, Oh-Lyong;Choi, Byung-Yearn;Cho, Soo-Ho;Lee, Jun-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.213-220
    • /
    • 1994
  • Damages on central nervous system induced by the exposure of microwave. However, the effects of microwave on ICP are not studied yet. The ICP affected by the condition of the brain has an significant effect on vital sign. So we investigated the changes of ICP of the rabbits after exposure. Twenty four rabbits were devided into 3 groups depending on the amount of exposure to microwave. One group was composed with 8 rabbits were exposed to microwave for 10 miniutes. Other were composed to microwave for 20 miniutes, 30 miniures, respectively. Intracranial pressure on each group were measured by subdural type ICP monitoring catheter immediately, first day, 3rd day, 5th day and 7th day after exposure of microwave. Results indicates that intracranial pressure of rabbits are not affected with statistical significance by exposure of microwave.

  • PDF

Analysis of Fracture Risk due to Alterations of Bone Quality by Metastatic Bone Tumor (전이성 골암으로 인한 골질 변화와 이로 인한 골절 위험성 분석)

  • Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.213-222
    • /
    • 2012
  • While much has been learned about the mechanisms of metastatic spread of cancer to bone, there has been little headway in establishing guidelines for monitoring the alteration in bone quality and estimating fracture risk. The aims of this study are, therefore, 1) to evaluate bone quality induced by metastatic bone tumor by analyzing the characteristics on bone microarchitecture and degree of bone mineralization and 2) analyze fracture risk increased secondary to the bone quality changes by metastatic bone tumor through calculating mechanical rigidities based on in-vivo micro CT images. For this study, eighteen female SD rats (12 weeks old, approximate 250 g) were randomly allocated in Sham and Tumor groups. W256 (Walker carcinosarcoma 256 malignant breast cancer cell) was inoculated in the right femur (intraosseous injection) in Tumor group, while 0.9% NaCl (saline solution) was injected in Sham group. The right hind limbs of all rats were scanned by in-vivo micro-CT to acquire structural parameters and degree of bone mineralization at 0 week, 4 weeks, 8 weeks, and 12 weeks after surgery. At the same time, urine was collected by metabolic cages for a biochemical marker test in order to evaluate bone resorption. Then, bone metastasis had been directly identified by positron emission tomography. Finally, axial, bending and torsional rigidities had been calculated based on in-vivo micro CT images for predict fracture risk. The results of this study showed that metastatic bone tumor might induce significant decrease in bone quality and increase of fracture risk. This study may be helpful to monitoring a degree of bone metastasis and predicting fracture risk due to metastatic bone tumor. In addition, this noninvasive diagnostic methodology may be utilized for evaluating other bone metabolic diseases such as osteoporosis.

Respiratory Effort Monitoring Using Pulse Transit Time in Human (인체에서 맥파전달시간을 이용한 호흡노력 모니터링)

  • 정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.485-489
    • /
    • 2002
  • In this study. respiratory efforts were monitored by the change of pulse transit time (PTT) which is related with the arterial pressure PTT is the time interval between the peak of R wave in ECG and the maximal slope point of photoplethysmogram(PPG). Biosignals, ECG and finger photoplethysmogram(PPG), were converted to digital data, and PTT was evaluated in personal computer with every heart beat. Results were presented as a graph using spline interpolation. The software was implemented in C$\^$++/ as a window-based application program. PTT was periodically changed according to airflow in resting respiration. In the resting respiration, PTT was changed according to the respiratory cycle. The amplitude of PTT fluctuation was increased by deep respiration, and increased by partial airway obstruction. These results suggest that PTT is responsible to respiratory effort which could be evaluated by the pattern of PTT change. And it is expected that PTT could be applied in the monitoring of respiratory effort by noninvasive methods, and is very useful method for the evaluation of respiratory distress.

Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods (온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화)

  • Kim, Jong-Min;Kumar, Suchit;Jo, Young-Seung;Park, Joshua Haekyun;Kim, Jeong-Hee;Lee, Chulhyun;Oh, Chang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

Development of Continuous ECG Monitor for Early Diagnosis of Arrhythmia Signals (부정맥 신호의 조기진단을 위한 연속 심전도 모니터링 기기 개발)

  • Choi, Junghyeon;Kang, Minho;Park, Junho;Kwon, Keekoo;Bae, Taewuk;Park, Jun-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.45-50
    • /
    • 2021
  • With the recent development of IT technology, research and interest in various bio-signal measuring devices are increasing. But studies related to ECG(electrocardiogram), which is one of the most representative bio-signals, particularly arrhythmic signal detection, are incomplete. Since arrhythmia has various causes and has a poor prognosis after onset, preventive treatment through early diagnosis is best. However, the 24-hour Holter electrocardiogram, a tool for diagnosing arrhythmia, has disadvantages in the limitation of use time, difficulty in analyzing motion artifact due to daily life, and the user's real-time alarm function in danger. In this study, an ECG and pulse monitoring device capable of continuous measurement for a long time, a real-time monitoring app, and software for analysis were developed, and the trend of the measured values was confirmed. In future studies, research on derivation of quantitative results of ECG signal measurement analysis is required, and further research on the development of an arrhythmic signal detection algorithm based on this is required.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

A study on the extraction of risk factor and its application for senile dementia patient at home based on accidental cases (사고사례를 통한 재가치매환자의 위험요소 추출 및 그 활용에 관한 연구)

  • Lee, Hang-Woon;Eom, Jin-Sup;Choi, Mi-Hyun;Lee, Soo-Jeong;Choi, Jin-Seung;Moon, Seok-Woo;Tack, Gye-Rae;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.12 no.1
    • /
    • pp.11-18
    • /
    • 2009
  • The purpose of this study was, first, to extract the risk factor by investigating several cases of accident of senile dementia patient at home, and second, based on these results to provide basic information for the determination of monitoring factor for the care of senile dementia patient. Basic and behavioral characteristics, Short form of Samsung Dementia Questionnaire (S-SDQ), Activities of Daily Living (ADL), and cases of accident were investigated with 55 senile dementia patient at home (16 male, 39 female). Based on these questionnaires, risk factors were extracted and frequency, cooccurrence frequency, and occurring place of risk factors, presence or not, region, and degree of injury were investigated. Frequency between risk factors and behavioral characteristics, ADL, and S-SDQ was analyzed by crosstabulation frequency analysis. Results showed that 12 risk factors were extracted, and the frequency of 'going out' was the highest, and risk factors for injury were 'tumble', 'bump', 'slip', and 'fall'. Cooccurrence frequency analysis showed that the occurrence of 'fall', 'going out', 'fire of gas', and 'violence' with other factors was relatively higher than others. The occurring place of risk factor was the highest in home neighborhood, and the region of injury in knee, and the degree of injury with bruise. Crosstabulation frequency analysis showed that factors which had difference in frequency of risk factor were behavioral disorder, disorder of daily living and ADL. Factor which had difference in frequency due to the degree of behavioral disorder and disorder of daily living was 'going out', and factors which had difference in frequency due to the degree of ADL were 'slip' and 'fire of gas'.

  • PDF