• 제목/요약/키워드: Biomedical Engineering

검색결과 7,029건 처리시간 0.029초

플라스틱 광섬유를 이용한 호흡센서의 개발 (Development of a Respiration Sensor Using Plastic Optical Fiber)

  • 유욱재;백지윤;조동현;장경원;서정기;허지연;이봉수;조영호;박병기;문주현
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.489-494
    • /
    • 2009
  • In this study, we fabricated a plastic optical fiber based sensor which can monitor the respiration of a patient. The circumference changes of the abdomen were measured using a mirror, a light source and optical detectors because the circumferences of the abdomen could be varied with respiration. The intensity of the reflected lights were measured according to the changes of distance between mirror and plastic optical fiber connected to a light source and a photodiode-amplifier system using a Y-coupler. The respiration signals of fiber-optic sensor system were compared with those of the respiratory and temperature transducers of the $BIOPAC^{(R)}$ system. It is expected that a fiber-optic respiration sensor could be developed for real time respiration monitoring during MRI procedure based on this study.

1차원 광섬유 팬텀선량계를 이용한 치료용 광자선의 피부 및 선량보강영역에서 상대선량 측정 (Measurement of Relative Depth dose of Therapeutic Photon Beam Using One-Dimensional Fiber-Optic Phantom Dosimeter)

  • 문진수;장경원;유욱재;서정기;박장연;조영호;이봉수
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.96-101
    • /
    • 2011
  • In this study, we fabricated a fiber-optic phantom dosimeter by arraying square type of plastic optical fibers in a PMMA phantom for measuring relative depth doses of therapeutic photon beams. To minimize the cross-talk between fiber-optic dosimeters, we selected appropriate septum by measuring leaked scintillating lights according to the various kinds of septa. In addition, we measured percentage depth doses of 6, 15 MV photon beams using a fiber-optic phantom dosimeter.

An Array-Type RGB Sensor for Precision Measurement of pH

  • Kim, Ji-Sun;Oh, Han-Byeol;Kim, A-Hee;Kim, Jun-Sik;Lee, Eun-Suk;Goh, Bong-Jun;Choi, Ju-Hyeon;Shin, Ye-Ji;Baek, Jin-Young;Lee, Ki Sung;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.700-704
    • /
    • 2015
  • As pH is a widely used index in chemical, medical, and environmental applications, research on pH sensors has been active in recent years. This study obtained RGB values by measuring the reflected light from a liquid sample to detect fine changes in pH, and performed mathematical modeling to investigate the relationship between the detected optical signal and pH value. Also, the trends in pH changes were easily identified by analyzing RGB values and displaying them in the color coordinate for easy visualization of data. This method implemented a user-friendly system that can measure and analyze in real time. This system can be used in many fields such as genetic engineering, environmental engineering, and clinical engineering, because it not only can measure pH but also replaces a colorimeter or turbidimeter.

반사형 소자를 이용한 시료의 컬러정보 및 농도분석 (An Optical Technique for Concentration Measurement by Color Analysis)

  • 이태희;김지선;정구인;최주현;오한별;김아희;정현철;조영빈;전재훈
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1121-1127
    • /
    • 2014
  • Many studies have been done to measure and analyze color for various purposes. Visual assessment has lack of objectivity and the equipment for color measurement is very expensive. In this study, we developed a device for quantitative analysis of the color using optical elements. With the color sensor, the ratio of RGB was calculated by measuring the light intensity that is reflected from an object. Inverse transformation of optical signal was performed to detect the color density. The suggested color analyzer can detect color information as well as sample concentration. Results of this study are expected to be used in various medical fields such as pH indicator and urine analysis.

새로운 학부 의공학 교육과정의 일환으로 의공학 실험과목의 제안 (A proposal for Biomedical Engineering Laboratory Class as a Part of a Novel Curriculum for Biomedical Engineering Education)

  • 박현진;지영준;서종범
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권4호
    • /
    • pp.289-294
    • /
    • 2011
  • Laboratory class is an integral part of biomedical engineering education. Current biomedical engineering curriculum in Korea mostly includes mandatory laboratory classes. Most of the Korean biomedical laboratory classes focus on electrical engineering aspects, while molecular/biological engineering aspects are neglected. Many leading universities in U.S.A. offer a more balanced laboratory class where both electrical engineering aspects and molecular/biological engineering aspects are considered. As a part of an effort to enhance undergraduate biomedical engineering education, a new biomedical engineering laboratory class is proposed to offer a more balanced laboratory learning experience.

광섬유와 OTDR을 이용한 실시간 수위 및 온도 측정 (Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR)

  • 심혁인;유욱재;신상훈;장재석;김재석;장경원;조승현;문주현;이봉수
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1239-1244
    • /
    • 2014
  • In this study, two fiber-optic sensors were fabricated to measure water level and temperature using optical fibers, a coupler, a Lophine and an OTDR (optical time-domain reflectometer). First, using Fresnel's reflection generated at the distal-ends of each optical fiber, which was installed at different depth, we measured the water level according to the variation of water level. Next, we also measured the temperature of water using a temperature sensing probe based on the Lophine, whose absorbance changes with the temperature. The measurable temperature range of the fiber-optic sensor is from $5^{\circ}C$ to $65^{\circ}C$ because the maximum operation temperature of the optical fiber without a physical deterioration is up to $80^{\circ}C$.

핵의학 적용을 위한 광섬유 기반의 알파/베타 검출기의 제작 및 특성분석 (Fabrication and Characterization of a Fiber-Optic Alpha/Beta Detector for Nuclear Medicine Application)

  • 홍승한;유욱재;신상훈;서정기;한기택;전다영;조승현;이봉수
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.367-373
    • /
    • 2012
  • We fabricated a fiber-optic alpha/beta detector, which is composed of a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer, to obtain the energy spectra of radioactive isotopes. As inorganic scintillators of a sensing probe, a ZnS(Ag) film was coupled with a $CaF_2$(Eu) crystal for alpha and beta spectroscopy. In this study, $^{210}Po$ and $^{90}Sr$ were used as alpha and beta sources, respectively, and we measured the radiation energy spectra using a fiber-optic alpha/beta detector to identify alpha and beta emitting radionuclides for nuclear medicine application. Also, the variations of energy spectrum were obtained according to the length of plastic optical fiber.

적외선 투과 광섬유를 이용한 고주파 열치료 과정에서의 온도분포 측정 (Measurements of temperature distribution using an infrared optical fiber during radiofrequency ablation)

  • 유욱재;서정기;조동현;장경원;신상훈;이봉수;탁계래;박병기;문주현
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.397-405
    • /
    • 2008
  • In this study, we have measured temperature distribution using infrared optical fibers during radiofrequency ablation (RFA). Infrared radiations generated from the water around inserted electrode are transferred by silver halide optical fibers and are measured by a thermopile sensor. Also, the output voltages of a thermopile sensor are compared with those of the thermocouple recorder. It is expected that a noncontact temperature sensor using an infrared optical fiber can be developed for the temperature monitoring during RFA treatments based on the results of this study.