• Title/Summary/Keyword: Bioelectric

Search Result 64, Processing Time 0.021 seconds

An Electromyographic Study of the Efficacy of Mandibular Movement Esercise on Opening Limitation (개구제한시 하악운동연습의 효과에 관한 근전도학적 연구)

  • Chang-Kwon Song;Kyung-Soo Han;Ho-In Jung
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.1
    • /
    • pp.61-71
    • /
    • 1992
  • 52 Dental students without masticatory problems were selected for this study. They were trained on several mandibular position and mandibular movement exercise, that is, rest position, light bite, tapping, hinge opening, habitual opening, opening limitation, stretch exercise, resistance exercise and clenching. The objectives of this study was to investigate the effects of mandibular movement exercise, especially stretch and resistance, on the experimentally guided limited mouth opening. Muscle activity of the anterior temporalis and the masseter on above mentioned position or exercise were recorded with bioelectric processor EM2(Myotronics, U.S.A.) and the data were processed with SPSS. The obtained results were as follows : 1. Activity of the muscles at rest position were decreased with mandibular movement exercise. 2. Forceful mouth opening on opening limitation increased muscle activity greatly, especially of the masseter. 3. On opening limitation, stretch or resistance exercise was very efficient for decrease of muscle activities. 4. There were no difference of muscle activity between on hinge opening and on habitual opening. Therefore, for muscle relaxation, the two movement exercise can be used interchangeably.

  • PDF

Development of a Excercise Prescription Device using EMG Signal (근전도 신호를 이용한 운동 처방 장치 개발)

  • Kim, Ho-joon;Lee, Jun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.152-157
    • /
    • 2012
  • In this paper, we develop a muscle exercise prescription system and present a prescription method by analyzing bioelectric signal of human muscles. This system is designed to give right exercise prescriptions include strength, duration, frequency of exercise after diagnosing personal body condition using EMG(Electromyography). With the help of these prescriptions all users can keep there optimum exercise status and avoid excess exercise symptom and, we van utilize in all the measurements like abnormal posture, muscle power, muscle regidity, muscle fatigue, muscle balance. Also easily accessable system can offer variable utilizations such as in health care center, sports center, social welfare center, social medical center, school, and kinder garden.

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.

Health Promotion Lifestyle According to Self-Perception of Obesity and Objective Status Measured by Bioelectric Impedance Analysis in College Women (여대생의 주관적 체형지각과 생체전기 임피던스법으로 측정한 비만도에 따른 건강증진 생활양식)

  • Chang, Eun-Young;Kim, Jeong-Sun;Shin, Su-Jin
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.5
    • /
    • pp.693-699
    • /
    • 2009
  • Purpose: The purpose of this study was to identify congruence between self-perception and objective status of obesity according to %Fat, and to investigate health promotion lifestyle in college women. Methods: The participants were a convenience sample of 392 college women who were eligible and agreed to participate in this study. Respondents were asked questions using a health promotion lifestyle profile and were evaluated for their body composition using InBody 3.0. The data were analyzed with SPSS 14.0 program, which was used for Chi square, ANOVA, and post-hoc comparison with Scheffe. Results: The major findings were as follows; 1) Overall, 41.8% of participants misclassified their perceived status of weight by %Fat standards and kappa was 0.329. 2) Two percent were underweight by BMI but overweight by %Fat and 39.0% normal weight by BMI but overweight by %Fat. 3) There were significant differences in health promotion lifestyle according to self-perception of body weight but there was no difference in health promotion lifestyle according to %Fat standards. Conclusion: These findings suggest the necessity for development and application of tailored health promotion program based on self-perception of body weight and %Fat in order to reform incorrect body image and health behavior in college women.

Effects of the Changes of Mandibular Position on the Muscle Activity in Masseter and Anterior Temporalis and on the Bite Force (하악위의 변화가 교근과 전측두근의 근활성 및 교합력에 끼치는 영향)

  • Sun-Oh Kwon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.13 no.1
    • /
    • pp.43-52
    • /
    • 1988
  • The author studied masticatory muscle activity and bite force in normal persons without Temporomandibular Disorders(TMD) signs and symptoms, The number of subjects was 15, and the age of them was from 22 to 25 years. Electromyography was used to record the muscle activity in tapping and clenching movement with or without occlusal splint. 3 splints were made from 3 different mandibular position, that if, centric occlusion position, Rocabado's mandibular rest position, Dawson's centric relation position. The thickness of splint was 3.0-3.5㎜ at molar region. The muscle examined were Masseter and Anterior Temporalis attached with surface electrodes and the device used to measure the EMG level was Bioelectric processor Model EM2. After recording the EMG, the author measured the bite force level in clenching movement with bite force meter Model MPM-3000 in the dame position used in the EMG experiment. The obtained results were as follow : 1. With occlusal splints insetion, the amount of decreased muscle activity in Anterior Temporalis was more than those in Masseter. 2. In the three maxillomandibular relationships with occlusal splints, Masseter showed slightly increased level of muscle in centric occlusion but Ant. Temporalis showed decreased level of muscle activity reversely in that position. 3. Muscle activities between Rocabado's rest position and Dawson's centric relation position were generally similar whatever the muscles or the movements the author examined. 4. Bite force in clenching movement increased with splints insertion, especially with the splint registered in centric occlusion position.

  • PDF

Influence of Interference of the Non-chewing Side on Electromyographic Activity of Masticatory Muscles (비저작측 교합간섭이 저작근 활성도에 미치는 영향)

  • Hun-Bong Kwan;Hong-So Yang
    • Journal of Oral Medicine and Pain
    • /
    • v.13 no.1
    • /
    • pp.23-33
    • /
    • 1988
  • The purpose of this study was to standardized and classify the coordination pattern among the chewing side and non-chewing side masseter and anterior muscles, in terms of EMG values on lateral excursion, clenching, and mastication in presence of the non-chewing side. In this study, 25 subjects were selected for experiment of lateral excursion, clenching and mastication and EMG value of the masseter and anterior temporal muscle on both sides were recored 2 times respectively. The bioelectric processor model EM2(Myo-tonic research, INC. U.S.A.) with the surface electrodes were used to record the EMG activity during all experimental procedures. The results were as follows : 1. During lateral excursion on intereference of non-chewing side, the EMG values of the temporal muscle were significantly more prominent than those of the temporal muscle on the non-chewing side. The EMG values of non-chewing side were significantly more prominent than those of chewing side on the both side masseter muscle and those of chewing side were significantly more prominent than those of non-chewing side on the both side temporal muscle. 2. During clenching on the occlusal interferance, the EMG values of non-chewing side masseter muscle were most prominent. 3. During mastication on the occlusal interferance, the EMG values of the chewing side temporal muscle were most prominent and those of non-chewing side temporal muscle were the lowest. 4. The EMG values of temporal muscle of non-chewing side on interferance were significantly more prominent than those of canine guidance during lateral excursion. 5. During clenching on the occlusal interferance, the EMG values of the masseter and the temporal muscles of the non-chewing side were significantly more prominent than canine guidance, but those of chewing side temporal muscle on canine guidance were significantly more prominent than those of interferance. 6. During mastication on canine guidance, the EMG Values of the temporal muscle on the chewing side, the masseter muscle on the chewing side and the temporal muscle on the non-chewing side were more prominent than those of interferance, but temporal muscle of non-chewing side was not different between canine guidance and occlusal interferance on non-chewing side.

  • PDF

Factors influencing the bio-impedance data in tissue segments along the three arm meridians: a pilot study

  • Lim, Chi Eung Danforn;Wong, Felix Wu Shun;Smith, Warren
    • CELLMED
    • /
    • v.1 no.1
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Bioelectric impedance measurements have been reported to show significant variation between individuals. Different physiological conditions like thickened skin, obesity, and fluid retention can affect the impedance measurement. Therefore, it is important to learn what other factors can affect the measurements of impedance even in healthy individuals. Such information is a prerequisite for understanding the changes in impedance associated with acupuncture treatment. This study investigated the bio-impedance properties of tissue segments in the arms of a number of healthy subjects, so as to define the factors that might influence the variation of the bio-impedance data in acupuncture meridians studies. 51 healthy subjects were recruited through Liverpool Hospital, Sydney. Demographic data was collected from each subject including the age, sex, BMI, and time since most recent meal. Electrodes were applied to the forearms of each test subject. Measurements were done by a purpose-built Bio-Impedance Research Device (BIRD-I) which allowed the determination of core resistance (Rc) and core reactance (Xc) of each of the three meridian tissue segments on the anterior surface of the forearm. No significant difference was found in the core resistance attributable to age group, gender, BMI or meal intake. However, a statistically significant trend in increasing resistance from the radial to ulnar aspect of the forearm (p < 0.001) was found. No significant difference was found in the core resistance of test tissue segments among the 51 healthy subjects measured in this study. However, the trend of increasing core resistance from the radial to ulnar aspects of the arm deserves further investigation.

The Association between Bone Density at Os Calcis and Body Composition in Healthy Children Aged 9-12 Years (9-12세 정상 아동에서 종골 골밀도와 체성분의 연관성)

  • Shin, Eun-Kyung;Kim, Ki-Suk;Kim, Hee-Young;Lee, In-Sook;Joung, Hyo-Jee;Cho, Sung-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.1
    • /
    • pp.72-79
    • /
    • 2004
  • Objectives : This cross-sectional study aimed to quantify the relationship between the bone mineral density at the os calcis and the body mass composition in healthy children. Methods : The areal bone mineral density was measured at the os calcis with peripheral dual energy X-ray absorptiometry. The fat free mass, fat mass and percentage fat mass were measured using bioelectric impedance, in 237 Korean children, aged 9 to 12 years. The sexual maturity was determined by self assessment, using standardized series of the 5 Tanner stage drawings, accompanied by explanatory text. Results : From multiple linear regression models, adjusted for age, sexual maturity and height, the fat free mass was found to be the best predictor of the calcaneal bone mineral density in both sexes. About 15 and 20% variabilities were found in the calcaneal bone mineral densities of the boys and girls, respectively, which can be explained by the fat free mass. After weight adjustment, the percentage fat mass was negatively associated with the calcaneal bone mineral density in both sexes. Conclusions : The findings of this study suggest that the fat free mass, among the body compositions, is the major determinant of bone mineral density at the os calcis in Korean children aged 9 to 12 years. Obesity, defined as the percentage fat mass, is assumed to have a negative effect on the calcaneal bone density in children of the same weight.

Comparison of Electrodermal Activity between Hypertensive and Non-hypertensive Subject in Health Screening Population (건강검진자 대상 고혈압 유무에 따른 피부전기활동성 비교 연구)

  • Kim, Young Eun;Kim, Chul;Yea, Sang Jun;Yang, Chang Sop;Song, Mi Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.847-852
    • /
    • 2013
  • The aim of this study was to investigate the difference of electrodermal activity between the hypertensive and non-hypertensive subjects. A total 161 subjects who visited a hospital for health check ups from August 2011 through November 2011 and from September 2012 through November 2012 were included in this study. We divided the subjects into two groups by blood pressure, hypertension group(81 patients) and non-hypertension group(180 subject). Then we compared electrodermal activity between two groups by using the autonomic bioelectric response device model CP-6000A. The data was analyzed by independent t-test and logistic regression. In this study, there was a significant difference in electrodermal activity(the mean absolute value of positive, negative pulse conductivity) between hypertensive and normotensive group in t-test and electrodermal activity showed the significant influence on the prevalence risk of hypertension with age, body mass index and dyslipidema in binominal logistic regression. In conclusion, hypertensive patients had high level of electrodermal activity compared with normotensive subjects and this finding suggests that electrodermal activity which is explained excess tendency in Korean traditional medicine could be used for diagnosis in hypertension patients at Korean traditional medical clinic.

Usefulness of Abdominal Fat Measured by Computed Tomography and Bioelectric Impedance Analysis as an Obesity Index (컴퓨터단층촬영과 생체전기 저항 분석법으로 측정된 복부지방의 비만지표로서의 유용성)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.807-813
    • /
    • 2011
  • For obesity management requires accurate measurement of abdominal fat. The purpose of this study was to find out the correlation between abdominal fat and lipid measured with BIA and CT. Secondly, This study investigate for usefulness of abdominal fat measured by BIA and CT as an obesity index. As a result, TG showed higher value in the overweight obese group than normal group but HDL showed lower value in the overweight obese group than normal group. TG and HDL appeared significantly relationship with by BIA and CT in the normal group. However, in the overweight obese group TG showed significantly relationship with the BIA. According to multiple regression analysis on BMF and TAF was affected by HDL in the normal group. And BMF, %BF was affected by TG in overweight obese group. In conclusion, abdominal fat showed significant correlation with lipid. Abdominal fat measured by BIA and CT to assess obesity index is considered as a useful way to evaluate.