• 제목/요약/키워드: Bioabsorbable system

검색결과 9건 처리시간 0.026초

흡수성과 비흡수성 내고정물 사용 후 관골 골절 환자의 자각증상의 차이 (A Comparative Study of the Subjective Symptoms of Bioabsorbable and Metallic Osteofixation System in Zygomatic Bone Fracture)

  • 박우진;신혜경
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.227-230
    • /
    • 2005
  • The surgical treatment of craniofacial disorders, using metallic internal osteofixation system has inspired an evolution with advanced operative technique and fixation devices over past two decades. As any other surgical procedures, this procedure also associates problems such as infection, palpability, loosening, and restrict craniofacial skeleton growth, which lead to undue secondary operations for removal. These problems are improved by using bioabsorbable osteofixation system. We compared the patient's subjective symptoms using bioaborbable system versus metallic osteofixation system in zygomatic bone fracture. we should take the individual steps (postoperative 2 weeks, and 1 year) in treating fractured zygoma. From August, 2001 to August, 2003, we used bioabsorbable osteofixation system in 28 patients in zygomatic fracture ($Biosorb^{TM}FX^{(R)}$) and compared 23 patients who were treated with metallic osteofixation system. There was no significant difference in the both groups in subjective symptoms and postoperative result.

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

  • Jeon, Hong Bae;Kang, Dong Hee;Gu, Ja Hea;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • 제43권1호
    • /
    • pp.40-45
    • /
    • 2016
  • Background Bioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws. Methods A total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland) plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA) in 61 patients. Their mean age was 35.2 years (range, 15-84 years). Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla. Results Complications occurred in eight (3.4%) of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction. Conclusions Inadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.

The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

  • Choi, Won Chul;Choi, Hyun Gon;Kim, Jee Nam;Lee, Myung Cheol;Shin, Dong Hyeok;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.135-139
    • /
    • 2016
  • Background: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant removal has been developed in the last decade. The purpose of this study is to share the experience of authors and to demonstrate the efficacy of bioabsorbable mesh in a variety of craniofacial trauma operations. Methods: Between October 2008 and February 2015, bioabsorbable meshes were used to reconstruct various types of craniofacial bone fractures in 611 patients. Any displaced bone fragments were detached from the fracture site and fixed to the mesh. The resulting bone-mesh complex was designed and molded into an appropriate shape by the immersion in warm saline. The mesh was molded once again under simultaneous warm saline irrigation and suction. Results: In all patients, contour deformities were restored completely, and bone segments were fixed properly. The authors found that the bioabsorbable mesh provided rigid fixation without any evidence of integrity loss on postoperative computed tomography scans. Conclusion: Because bioabsorbable meshes are more flexible than bioabsorbable plates, they can be molded and could easily reconstruct the facial bone in three dimensions. Additionally, it is easy to attach bone fragments to the mesh. Bioabsorbable mesh and screws is effective and can be easily applied for fixation in various craniofacial trauma reconstructive scenarios.

생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료 (Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures)

  • 권덕주;이용범;신준
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF

슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기- (Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note-)

  • 인용;박원종;박종범;홍승환
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.60-63
    • /
    • 2002
  • 목적 : 네 겹의 슬괵건을 이용한 전방십자인대 재건술시 대퇴터널을 횡고정 핀과 흡수성 간섭나사로 함께 고정하는 수기를 소개하고자 한다. 수술 술기 : 반건양건과 박건을 채취하여 네 겹으로 준비하였다. 경골터널과 대퇴터널을 만드는데 대퇴터널의 깊이는 35 mm로 하였다. Rigidfix system의 가이드를 삽입하고 가이드의 위쪽 관에만 구멍을 내었다. 이식건을 통과시킨후 횡고정 핀 을 고정하였다. 이후 이식건을 경골쪽으로 당기면서 흡수성 간섭 나사로 고정하였다. 결론 : 슬괵건 전방십자인대 재건술시 횡고정 핀과 흡수성 간섭나사를 이용한 대퇴터널 고정은 강한 초기 고정과 이식건의 골통합을 촉진시킬 수 있는 좋은 방법으로 사료되어 소개하였다.

  • PDF

남아있는 다발을 보존한 전방십자인대 재건술 (Arthroscopic Anterior Cruciate Ligament Reconstruction with Remnant Bundle Preservation)

  • 안진환;이상학
    • 대한관절경학회지
    • /
    • 제13권2호
    • /
    • pp.87-96
    • /
    • 2009
  • 최근 전방십자인대 손상의 치료에 남아있는 인대 다발이 이식건의 생물학적 치유를 도우며 고유 수용감각(proprioception) 기능을 유지할 뿐만 아니라 슬관절의 전방 전위 억제의 생역학적 기능을 가지는 것으로 연구되고 있다. 이러한 이론을 바탕으로 남아있는 전방십자인대를 보존하는 노력들은 다양하게 시도되고 있다. 전방십자인대 손상의 자연 경과는 아직도 논란이 되고 있으나 선택적인 환자에 있어서 보존적 치료는 비교적 좋은 결과를 얻을 수 있으므로 불필요한 재건술을 줄일 수 있다. 최근 시도되고 있는 선택적 다발 재건술 및 남아있는 다발을 보존하는 전방십자인대 재건 수술 수기들은 다양한 방법으로 시도되고 있으며 남아있는 다발을 보존하는 장점이 있으나 협소한 적응증을 가진다. 저자들의 남아있는 다발을 보존하는 전방십자인대 재건술은 자가 슬괵건을 이용한 단일다발 재건술을 시행하면서 잔존하는 이완된 다발에 봉합사를 통과시킨 후 봉합사를 추가적인 터널 없이 bioabsorbable cross pin (RIGIDfix system, Mitek, Johnson & Johnson, USA) 구멍을 통하여 당기고 고정하는 방법이다. 전방십자인대 재건술시 남아있는 다발을 보존하는 방법은 이식건의 생물학적 치유을 촉진하고 또한 경골 부착부에 남아있는 기계수용체를 보존하므로 기능적 회복에 도움이 될 것으로 기대된다. 저자들의 방법은 비교적 광범위한 적응증을 가지며 적은 합병증으로 남아있는 다발을 효과적으로 보존할 수 있는 술식으로 전방십자인대 수술시 좋은 치료 선택의 하나로 사료된다.

  • PDF

In Vitro 분해가 PLA/PEG 용융블렌드 섬유의 무게감량률 및 인장강도에 미치는 영향 (Effect of In Vitro Degradation on the Weight Loss and Tensile Strength of PLA/PEG Melt Blend Fiber)

  • 윤철수;지동선
    • 폴리머
    • /
    • 제33권6호
    • /
    • pp.581-587
    • /
    • 2009
  • PLA와 PEG를 사용하여 용융블렌드 방법으로 PLA/PEG 블렌드 섬유를 제조한 후 in vitro 환경조건인 pH7.4, 온도 $37\;^{\circ}C$의 완충용액에서 1~8주 동안 가수분해한 다음 무게감량률 및 인장강도 등에 미치는 영향을 검토하였다. 가수분해 시간이 1주에서 8주까지 증가함에 따라 블렌드 시간은 10~30분으로, PEG 함량은 5~30 wt%로 증가할수록 PLA/PEG 블렌드 섬유의 무게감량률은 증가하는 경향이, 인장강도 및 인장탄성률은 감소하는 경향이 현저하게 나타남을 확인하였다. 결론적으로 가수분해 시간 2주까지는 PLA/PEG 블렌드 섬유의 무게 감량률은 약 0.9% 이내이고 강도유지율은 약 90% 이상을 나타냄으로써 임계상처치유기간 중 양호한 강도가 유지될 수 있음을 확인하였다.

자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 - (Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes)

  • 안진환;이상학;안형권;강홍제
    • 대한관절경학회지
    • /
    • 제9권2호
    • /
    • pp.222-231
    • /
    • 2005
  • 목적: 저자들은 5가닥의 자가 슬괵건을 이용하여 기존의 전내측 다발에 부가적인 후외측 다발을 통한 전방 십자인대 이중 다발 재건술을 소개하고자 한다. 수술 술기: 경골 터널은 기존의 단일 터널 방법을 사용하였고, 대퇴 터널은 전내측과 후외측 다발을 위한 이중 터널 방법을 사용하였다. 전내측 대퇴 터널은 최소한의 대퇴 과간 절흔 성형술 후 기존의 방법과 동일하게 11시 혹은 1시 방향에 대퇴과 절흔의 후방 경계(over-the-top)에서 후방 피질골이 1 mm 두께로 남아 있게 만든다. 또한 후 외측 대퇴 터널은 outside-in 방법을 사용하여 관절 내 터널 위치는 슬관절 90도 굴곡 상태에서 외측 반월상 연골 후각의 경골 부착부 내연(inner margin)에서 외측 대퇴과 내측벽의 상방 $5{\sim}7mm$ 부위에 4.5 mm reamer 이용하여 만들어 준다. 이중 다발을 위한 이식건으로 전내측 다발은 기존의 4가닥 슬괵건을 사용하고 후외측 다발은 반건양건 단일 가닥으로 만든다. 대퇴 터널 고정 방법으로 전내측 다발은 rigid fix system으로 고정하며 후외측 다발은 관절 밖에 miniplate를 이용하여 endobutton 방식으로 결찰로 고정한다. 이 후 경골 터널 고정은 슬관절을 $10{\sim}20$도 굴곡 상태에서 이중 다발을 함께 인장 강도를 주고 간섭 나사못으로 고정하고 post tie로 보강한다. 결론: 저자들은 비교적 우수한 결과를 보여주었던 기존의 전내측 다발에 회전 안정성을 위한 부가적인 후외측 다발을 통해 5가닥(경우에 따라 6가닥)의 자가 슬괵건을 이용한 이중 다발 재건술을 시행함으로써 좋은 결과가 기대된다.

  • PDF