A Comparative Study of the Subjective Symptoms of Bioabsorbable and Metallic Osteofixation System in Zygomatic Bone Fracture

흡수성과 비흡수성 내고정물 사용 후 관골 골절 환자의 자각증상의 차이

  • Park, Woo Jin (Department of Plastic and Reconstructive Surgery, College of Medicine, Dongguk University) ;
  • Shin, Hye Kyoung (Department of Plastic and Reconstructive Surgery, College of Medicine, Dongguk University)
  • 박우진 (동국대학교 의과대학 성형외과학교실) ;
  • 신혜경 (동국대학교 의과대학 성형외과학교실)
  • Received : 2004.10.21
  • Published : 2005.03.10

Abstract

The surgical treatment of craniofacial disorders, using metallic internal osteofixation system has inspired an evolution with advanced operative technique and fixation devices over past two decades. As any other surgical procedures, this procedure also associates problems such as infection, palpability, loosening, and restrict craniofacial skeleton growth, which lead to undue secondary operations for removal. These problems are improved by using bioabsorbable osteofixation system. We compared the patient's subjective symptoms using bioaborbable system versus metallic osteofixation system in zygomatic bone fracture. we should take the individual steps (postoperative 2 weeks, and 1 year) in treating fractured zygoma. From August, 2001 to August, 2003, we used bioabsorbable osteofixation system in 28 patients in zygomatic fracture ($Biosorb^{TM}FX^{(R)}$) and compared 23 patients who were treated with metallic osteofixation system. There was no significant difference in the both groups in subjective symptoms and postoperative result.

Keywords

References

  1. Jeffrey AG, Facial AQ Alan RC: Early experience with biodegradable fixation for congenital pediatric craniofacial surgery. J Craniofac Surg 8: 110, 1997 https://doi.org/10.1097/00001665-199703000-00009
  2. Danzig LA, Woo SL-Y, Akeson WH: Internal fixation plates after fifty-six years of implantation: Report of a case. Clin Orthop Relat Res 149: 20, 1980
  3. Kukani RK, Pani KC, Neuman C, Leonard F: Polylactic acid for surgical implants. Atch Surg 93: 839, 1966 https://doi.org/10.1001/archsurg.1966.01330050143023
  4. Cutright DE, Hunsuck EE: The repair of fractures of the orbital floor using biodegradable polylactic acid. Oral Surg Oral Med Oral Pathol 33: 28, 1972 https://doi.org/10.1016/0030-4220(72)90204-6
  5. Eelco J. Bergarna DDS, Fred R, Rozema DDS, Ruud RM, Bos DDS, Wim C, De Br'uijn: Foreign body reactions to Resorbable Poly(L-Lactide) Bone plates and Screws Used for the fixation of Unstable Zygomatic Fractures. J Oral Maxillofac Surg 51: 666, 1993 https://doi.org/10.1016/S0278-2391(10)80267-8
  6. Epply BL, Sadove AM: Resorbable coupling fixation in craniosynostosis surgery: experimental and clinical applications. J Craniofac Surg 6: 477, 1995 https://doi.org/10.1097/00001665-199511000-00011
  7. Ferretti C, Reyneke JP: Mandibular, sagittal split osteotomies fixed with biodegradable or titanium screws: a prospective, comparative study of postoperative stability. Oral Surg Oral Med Pathol Oral Radiol Endod 93: 534, 2002 https://doi.org/10.1067/moe.2002.124091
  8. Brian LS, David HP, Dennis M, Gerard Kearns: The removal of plates and screws after Le Fort I osteotomy. J Oral Maxillofac Surg 56: 184, 1998 https://doi.org/10.1016/S0278-2391(98)90865-5
  9. Ashammakhi N, Peltoniemi H, Waris E, Suuronen R, Serlo W, Kellomaki M, Tormala P, Waris T: Developments in craniomaxillofacial surgery: use of self-reinforced bioabsorbable osteofixation devices. Plast Reconstr Surg 108: 167, 2001 https://doi.org/10.1097/00006534-200107000-00027
  10. Enislidis G, Lagogiannis G, Wittwer G, Glaser C, Ewers R: Fixation of zygomatic fractures with a biodegradable copolymer osteosynthesis system: short-and long-term results. Int J Oral Maxillofac Surg 34: 19, 2005
  11. Richard JL, John WF: Tissue changes adjacent to titanium plates in patients. J Cranio-Maxillofac Surg 30: 103, 2002 https://doi.org/10.1054/jcms.2002.0286
  12. Norholt SE, Pedersen TK, Jensen J: Le Fort I miniplate osteosynthesis: a randomized, prospective study comparing resorbable PLLA/PGA with titanium. Int J Oral Maxillofac Surg 33: 245, 2004 https://doi.org/10.1006/ijom.2003.0505
  13. Laine P, Kontio R, Lindqvist C, Suuronen R: Are there any complications with bioabsorbable fixation devices?: A 10 year review in orthognathic surgery. Int J Oral Maxillofac Surg 33: 240, 2004 https://doi.org/10.1006/ijom.2003.0510
  14. Schortinghuis J, Rudolf KMB, Vissink A: Complications of internal fixation of maxillofacial fractures with microplates. J Oral Maxillofac Surg 57: 130, 1999 https://doi.org/10.1016/S0278-2391(99)90224-0