• 제목/요약/키워드: Bioabsorbable

검색결과 72건 처리시간 0.024초

Bioabsorbable osteofixation for orthognathic surgery

  • Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.6.1-6.9
    • /
    • 2015
  • Orthognathic surgery requires stable fixation for uneventful healing of osteotomized bony segments and optimal remodeling. Titanium plates and screws have been accepted as the gold standard for rigid fixation in orthognathic surgery. Although titanium osteofixation is the most widely used approach, the use of bioabsorbable devices has been increasing recently. Biodegradation of bioabsorbable devices eliminates the need for a second operation to remove metal plates and screws. However, long-term stability and relapse frequency in bioabsorbable osteofixation are still insufficiently studied, especially in cases of segmental movements of great magnitude or segmental movements to a position where bony resistance exists. This paper reviews the background, techniques, and complications of bioabsorbable osteofixation and compares bioabsorbable and titanium osteofixation in orthognathic surgery in terms of skeletal stability.

Application of Bioabsorbable Plates in Orthognathic Surgery

  • Kim, Young-Kyun;Shim, Cheong-Hwan;Bae, Ji-Hyun;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권1호
    • /
    • pp.60-64
    • /
    • 2006
  • Backgrounds: Though they are considered as reliable devices, titanium plates and screws have limitations due to some potential problems. To overcome these problems, researches on bioabsorbable materials for internal fixation have been continuing. Recently, there are many clinical trials to apply biodegradable internal fixation devices in oral and maxillofacial surgery. The purpose of this study was to evaluate the clinical results of application of bioabsorbable plates and screws in orthognathic surgery. Methods: Fifty-four patients with dentofacial deformity (17 male patients and 37 female patients) were selected in this study. The patients were treated by internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm pretapped screws (Biosorb FX, Bionix Implants, Inc., Finland). The patients were evaluated for complications during the follow-up period. Results: Five patients (9.3%) experienced complications. All complications in these cases were infection. No other complications related with physical or mechanical properties of bioabsorbable plates were found such as malunion or nonunion, fractures of plates and loosening of screws. All complications were minor and adequately managed with drainage and supportive care with antibiotics coverage. Conclusions: From the results, the use of these fixation systems in orthognathic surgery will provide a promising alternative titanium fixation in appropriate cases.

Cephalometric evaluation of skeletal stability and pharyngeal airway changes after mandibular setback surgery: Bioabsorbable versus titanium plate and screw fixation

  • Phu Hnin Thet;Boosana Kaboosaya
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.181-190
    • /
    • 2024
  • Purpose: This study compared sequential changes in skeletal stability and the pharyngeal airway following mandibular setback surgery involving fixation with either a titanium or a bioabsorbable plate and screws. Materials and Methods: Twenty-eight patients with mandibular prognathism undergoing bilateral sagittal split osteotomy by titanium or bioabsorbable fixation were randomly selected in this study. Lateral cephalometric analysis was conducted preoperatively and at 1 week, 3-6 months, and 1 year postoperatively. Mandibular stability was assessed by examining horizontal (BX), vertical (BY), and angular measurements including the sella-nasion to point B angle and the mandibular plane angle (MPA). Pharyngeal airway changes were evaluated by analyzing the nasopharynx, uvula-pharynx, tongue-pharynx, and epiglottis-pharynx (EOP) distances. Mandibular and pharyngeal airway changes were examined sequentially. To evaluate postoperative changes within groups, the Wilcoxon signed-rank test was employed, while the Mann-Whitney U test was used for between-group comparisons. Immediate postoperative changes in the airway were correlated to surgical movements using the Spearman rank test. Results: Significant changes in the MPA were observed in both the titanium and bioabsorbable groups at 3-6 months post-surgery, with significance persisting in the bioabsorbable group at 1 year postoperatively (2.29°±2.28°; P<0.05). The bioabsorbable group also exhibited significant EOP changes (-1.21±1.54 mm; P<0.05) at 3-6 months, which gradually returned to non-significant levels by 1 year postoperatively. Conclusion: Osteofixation using bioabsorbable plates and screws is comparable to that achieved with titanium in long-term skeletal stability and maintaining pharyngeal airway dimensions. However, a tendency for relapse exists, especially regarding the MPA.

생흡수성판을 이용한 하악골 골절의 치료 : 일차보고 (TREATMENT OF MANDIBLE FRACTURES USING BIOABSORBABLE PLATES: PRELIMINARY STUDY)

  • 김영균;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권6호
    • /
    • pp.570-575
    • /
    • 2001
  • This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Thirty-four fractures of the mandible in 27 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pre-tapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 5.3 days. Patients were evaluated for complications during the follow-up period, which ranged from 2 to 18 months. Five patients(18.5%) experienced complications. These included infection (four patients), and premature occlusal contact(one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures with the advantage that they do not need to be removed.

  • PDF

중족골두 무혈성 괴사에서 생체흡수성 핀으로 고정한 배측 쐐기 절골술 (Dorsal Wedge Osteotomy Using Bioabsorbable Pins for the Treatment of Freiberg's Disease)

  • 공현식;백구현;김지형;정문상
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.59-63
    • /
    • 2005
  • Purpose: To present the procedure and results of dorsal wedge osteotomy fixated by bioabsorbable polyglycolide pins for the treatment of symptomatic Freiberg's disease. Materials and Methods: From January 1997 to December 2002, six patients with Freiberg's disease underwent dorsal wedge osteotomy of the metatarsal neck to bring the healthy plantar part of the metatarsal head into articulation. Bioabsorbable polyglycolide pins were used for the fixation and short-leg walking cast was applied for 4 weeks. Results: All patients returned to full daily activities without pain in three months after the operation. Radiographically, solid healing of the osteotomy was observed at average ten weeks. The active range of motion of the metatarsophalangeal joint increased by a mean gain of 30 degrees, and no complication such as displacement, osteolysis or sinus formation was observed. Conclusion: Dorsal wedge osteotomy fixated by bioabsorbable pins for patients with symptomatic Freiberg's disease is effective procedure that provides relatively early range of motion exercise and avoids second procedure for implant removal.

  • PDF

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 - (The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report -)

  • 임홍철;노경선;양재혁
    • 대한관절경학회지
    • /
    • 제10권1호
    • /
    • pp.87-90
    • /
    • 2006
  • 자가 슬개건을 이용한 전방십자인대 재건술 시 사용되는 생분해성 간섭나사로 인한 합병증은 많지 않다. 저자들은 슬개건을 사용한 전방십자인대 재건술 시 생분해성 간섭 나사로 이식건을 고정 후 경골과 대퇴골 터널에 발생한 지연성 염증반응 1예에 대해 보고하고자 한다.

  • PDF

생분해성 간섭나사를 이용한 전방 십자 인대 재건술 후 발생한 결절종 - 증례보고 - (Pretibial Ganglion after Anterior Cruciate Ligament Reconstruction with Bioabsorbable Interference Screw fixation $(Bioscrew^{\circledR})$ - A Case Report -)

  • 송은규;심상돈;김명선
    • 대한관절경학회지
    • /
    • 제6권2호
    • /
    • pp.188-191
    • /
    • 2002
  • 자가 슬괵건을 이용한 전방 십자인대의 재건술시 사용되는 Poly-L-Lactic-Acid 성분의 생분해성 간섭나사로 인한 합병증은 많지 않다. 저자들은 전방 십자 인대 재건술시 생분해성 간섭나사로 이식건을 고정 후 경골 터널 전방에 발생한 결절종에 대해 결절종 절제술과 동시에 간섭나사를 제거한1예에 대해 보고하는 바이다.

  • PDF

흡수성과 비흡수성 내고정물 사용 후 관골 골절 환자의 자각증상의 차이 (A Comparative Study of the Subjective Symptoms of Bioabsorbable and Metallic Osteofixation System in Zygomatic Bone Fracture)

  • 박우진;신혜경
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.227-230
    • /
    • 2005
  • The surgical treatment of craniofacial disorders, using metallic internal osteofixation system has inspired an evolution with advanced operative technique and fixation devices over past two decades. As any other surgical procedures, this procedure also associates problems such as infection, palpability, loosening, and restrict craniofacial skeleton growth, which lead to undue secondary operations for removal. These problems are improved by using bioabsorbable osteofixation system. We compared the patient's subjective symptoms using bioaborbable system versus metallic osteofixation system in zygomatic bone fracture. we should take the individual steps (postoperative 2 weeks, and 1 year) in treating fractured zygoma. From August, 2001 to August, 2003, we used bioabsorbable osteofixation system in 28 patients in zygomatic fracture ($Biosorb^{TM}FX^{(R)}$) and compared 23 patients who were treated with metallic osteofixation system. There was no significant difference in the both groups in subjective symptoms and postoperative result.