• 제목/요약/키워드: Bio-logger

검색결과 11건 처리시간 0.022초

바이오로거 부착 위치가 점농어(Lateolabrax maculatus)의 혈액 성상 및 바이오로거 부착효율에 미치는 영향 (Effect of Bio-logger Attachment Location on Blood Characteristics and Bio-logger Attachment Efficiency in Spotted Sea Bass Lateolabrax maculatus)

  • 오승용
    • 한국수산과학회지
    • /
    • 제56권5호
    • /
    • pp.651-659
    • /
    • 2023
  • The effect of bio-logger tagging location on blood characteristics and bio-logger attachment efficiency in spotted sea bass (mean body weight 2356.7 g) was investigated. The fish were tagged at four different tagging locations: no-tag (control), operculum attachment (OA), dorsal muscle attachment (DA), and cauda peduncle muscle attachment (CA). The blood properties and bio-logger attachment efficiencies were examined on days 1, 7, 14, and 35 after tagging the bio-logger at each tagging location. During the experimental periods, the concentrations of hematocrit and hemoglobin in whole blood, and GOT (glutamic oxaloacetic transaminase), GPT (glutamic pyruvic transaminase), total protein (TP), glucose, total cholesterol, cortisol, and superoxide dismutase in plasma were not affected by the attachment location of the bio-logger, however, the TP concentration was significantly lower in OA than in the control group on day 7. After tagging for 35 days, the efficiencies of bio-logger attachment in the OA, DA, and CA after tagging for 35 days were 33.3%, 100.0%, and 33.3%, respectively. These results indicate that, in our experimental condition, the most appropriate bio-logger attachment location is DA, providing basic information on bio-logger utilization methods for ecological and biological biotelemetry surveys of the spotted sea bass.

MEASUREMENT OF FIELD PERFORMANCE FOR TRACTOR

  • M. J. NahmGung;Park, C. H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.819-826
    • /
    • 2000
  • This study was performed to develop a measurement system of tractor field performance for plow and rotary operations. Measurement system for tractor consisted of torque sensors to measure torque of drive axles and PTO axle, speed sensors to measure rotational speed of drive axles and engine, microcomputer to control data logger, and data logger as I/O interface system. The measurement system was installed on four-wheel-drive tractor. Four-element full-bridge type strain gages were used for torque measurement of drive axles and optical encoders were used to measure speeds of drive axles and engine. Slip rings were mounted on the rotational axles. Signals from sensors were inputted to data logger that was controlled by microcomputer with parallel communication. Sensors were calibrated before the field tests. Regression equations were found on completion of the calibrations. The field experiment was performed at paddy fields and uplands. Rotary and plow were used when the tractor was operated in the field. Travelling speeds of the tractor were 1.9 km/h, 2.7 km/h, 3.7 km/h, 5.5 km/h, 8.2 km/h, and 11.8 km/h. Operating depths of implements were maintained approximately 20cm during the tests. Torque data of drive axles were different at each location during plow and rotary operations. Results showed that torque of rear axles were greater than those of front axles. Total torque were 6860 - 11064 Nm at the upland and 7360 - 14190 Nm at the paddy field for plow operations. It was found that torque at the paddy field were about 20% greater than those at the upland for plow operations. Torque data showed that rotary operations required less power than plow operation at the paddy field and the upland. Torque measurements at each axle for rotary operations were only 8 - 16% of plow operations in the upland and 15 - 20% in the paddy field.

  • PDF

A review on fish bio-logging for biotelemetry applications

  • Jikang Park;Sung-Yong Oh
    • Fisheries and Aquatic Sciences
    • /
    • 제26권12호
    • /
    • pp.698-707
    • /
    • 2023
  • Fish are an essential resource in human society, and while ecological research on them is challenging, it is absolutely necessary. Recent technologies enabled researchers to monitor underwater fish behavior. Acoustic signals, satellite-mediated location estimation, and light-based geolocation are powerful tools for tracking fish movements from freshwater to deep-sea habitats. These tools allow us to track various fish species and elucidate their ecology. Furthermore, based on these technologies, we can develop fisheries management plans and enhance aquaculture productivity. In this review, we also discuss challenges in improving current technologies and provide future recommendations for fish bio-logging studies.

Detection of Fever with Subcutaneously Implanted Thermo-Loggers in Cattle Administered with Lipopolysaccharide

  • Ro, Younghye;Bok, Jin-Duck;Lee, Hun-Jun;Kang, Sang-Kee;Kim, Danil;Lee, Yoonseok
    • 한국임상수의학회지
    • /
    • 제35권3호
    • /
    • pp.97-99
    • /
    • 2018
  • The aim of this study is to determine whether subcutaneous temperature (ST) was correlated with rectal temperature (RT) in cattle with inducing artificial fever. In order to determine the correlation between their temperatures, the experiment was performed as follow: Among nine Holstein steers, lipopolysaccharide (LPS) was intravenously administered at a dose of $0.5{\mu}g/kg$ of body weight to six Holstein steer, then, 6 ml of saline was administrated to three steers as a control group. After LPS injection, ST was recorded using subcutaneously implanted thermo-logger sensors at 10-min intervals, and RT was measured using a digital thermometer at 0, 1, 2, 3, 4, 8 and 12 h. In steers with LPS injection, RT was highest at 3 to 4 h and recovered to a pre-challenge temperature at 8-22 h. A similar fluctuation was shown in ST except for an unexpected decrease at 1 h, and a positive correlation between RT and ST was observed in LPS-challenged steers (r = 0.497, P = 0.04). This result suggests that ST could be utilized as an index for early detection of infectious diseases or physiological events.

Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers

  • Lee, Y.;Bok, J.D.;Lee, H.J.;Lee, H.G.;Kim, D.;Lee, I.;Kang, S.K.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권2호
    • /
    • pp.299-306
    • /
    • 2016
  • Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean${\pm}$standard deviation [SD], $37.1^{\circ}C$ to $37.36^{\circ}C{\pm}0.91^{\circ}C$ to $1.02^{\circ}C$). STs are $1.39^{\circ}C$ to $1.65^{\circ}C$ lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below $36.5^{\circ}C$ or $37^{\circ}C$, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below $36.5^{\circ}C$ or $37^{\circ}C$ resulting in a much improved mean${\pm}$SD of $37.6^{\circ}C{\pm}0.64^{\circ}C$ or $37.8^{\circ}C{\pm}0.55^{\circ}C$, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.

스투키의 가열에 의한 생체 신호 변화 특성에 대한 실험 연구 (Experimental Study on Bio-signal Characteristics of Stuckyi during Heating)

  • 남다현;김정배
    • 융복합기술연구소 논문집
    • /
    • 제6권1호
    • /
    • pp.7-11
    • /
    • 2016
  • An experiment was performed to show the bio-signal characteristics of the Stuckyi when was heated. To measure the bio-signal of the plant, this study used the electrode with copper(+) and constantan(-). The electrode was directly inserted into the Stuckyi stems. And used T-type thermocouple to measure the inside temperature of the Stuckyi. During the experiments, room temperature also measured with T-type thermocouple. Heating was made with hair dryer periodically that 3 times turned on for heating 5 min and off for non-heating 25 min. Under the situation, the responses of the Stuckyi including voltage potential and inside temperature were measured using data logger(HP-34970A) according to the distances(15cm, 30cm, 45cm) between hair dryer and the plant. Through the experiments, We knew that the inside temperature has similar level and behavior with the room temperature at normal state. And during heating period, the inside temperature and the potential were also simultaneously increased sharply. From the experiments, we revealed that the measuring system of bio-signal of the plant being proposed in this study can be useful to show the Characteristics of the plants.

돈사용 환기팬을 위한 돈사 내 온도 분포 특성 (Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System)

  • 김현태;김웅
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

IoT 기반 지능형 수위 모니터링 플랫폼 설계 및 구현 (Design and Implementation of IoT-Based Intelligent Platform for Water Level Monitoring)

  • 박지훈;강문성;송정헌;전상민
    • 농촌계획
    • /
    • 제21권4호
    • /
    • pp.177-186
    • /
    • 2015
  • The main objective of this study was to assess the applicability of IoT (Internet of Things)-based flood management under climate change by developing intelligent water level monitoring platform based on IoT. In this study, Arduino Uno was selected as the development board, which is an open-source electronic platform. Arduino Uno was designed to connect the ultrasonic sensor, temperature sensor, and data logger shield for implementing IoT. Arduino IDE (Integrated Development Environment) was selected as the Arduino software and used to develop the intelligent algorithm to measure and calibrate the real-time water level automatically. The intelligent water level monitoring platform consists of water level measurement, temperature calibration, data calibration, stage-discharge relationship, and data logger algorithms. Water level measurement and temperature calibration algorithm corrected the bias inherent in the ultrasonic sensor. Data calibration algorithm analyzed and corrected the outliers during the measurement process. The verification of the intelligent water level measurement algorithm was performed by comparing water levels using the tape and ultrasonic sensor, which was generated by measuring water levels at regular intervals up to the maximum level. The statistics of the slope of the regression line and $R^2$ were 1.00 and 0.99, respectively which were considered acceptable. The error was 0.0575 cm. The verification of data calibration algorithm was performed by analyzing water levels containing all error codes in a time series graph. The intelligent platform developed in this study may contribute to the public IoT service, which is applicable to intelligent flood management under climate change.

넙치(Paralichthys olivaceus) 산소 소비율에 미치는 Pop-up Satellite Archival Tag (PSAT) 체외 부착과 수온의 영향 (External Attachment of Pop-up Satellite Archival Tag (PSAT) and Water Temperature Affect Oxygen Consumption Rate of the Olive Flounder Paralichthys olivaceus)

  • 이근수;강필준;박혜미;오승용
    • 한국수산과학회지
    • /
    • 제56권5호
    • /
    • pp.660-666
    • /
    • 2023
  • This study aimed to examine the effect of external pop-up satellite archival tags (PSATs) attachment and water temperature on the oxygen consumption rate (OCR) of the olive flounder (mean body weight 2281.7 g). The OCRs of fish were measured under conditions of three different water temperature conditions (15, 20, and 25℃) and two different tagging methods [non-tagging, control; bio-logger external attachment with a miniature PSAT (dummy mrPAT), BEA] using a closed flow-through respirometer. The OCRs of fish linearly increased with the increase in water temperature in both the control and BEA (P<0.001); however, the OCRs of BEA were approximately 1.8-1.9 times lower than those of the control at each water temperature (P<0.001). The Q10 values of the control and BEA were the highest in the water temperature range of 15 to 20℃, but sensitivity to water temperature changes was higher in BEA than in the control. The metabolic energy loss rate (MEL) of fish increased with increasing water temperature regardless of external tagging, but the MEL of the control was higher than that of BEA (P<0.001). These results demonstrate that OCR, thermal sensitivity, and energy expenditure are all affected in adult olive flounder with external PSAT attachment.

시설원예용 조합형 다겹보온자재의 보온 특성 (Heat Insulation Characteristics of Multi Layer Materials for Greenhouse)

  • 정성원;김동건;이석건;남상헌;이용범
    • 생물환경조절학회지
    • /
    • 제18권4호
    • /
    • pp.341-347
    • /
    • 2009
  • 본 연구는 수출과채류 시설원예 재배농가의 에너지 절감을 위한 보온자재의 개발을 목표로 수행되었으며 본 보에서는 시설 온실에 사용되어지는 단일 보온자재와 조합형 다겹보온자재에 대해 보온 특성을 조사하기 위하여 실험과 수치해석을 수행하였다. 실험해석의 경우, 실험모듈을 통해 내부 열원의 보온 효과를 조사하기 위해 내 외부의 온도는 K형 열전대와 데이터 획득 장치로 측정하였고, 측정된 온도를 통해 보온자재의 보온특성을 구명하였다. 수치해석은 상용코드인 CFX-11을 이용하였고 다겹보온자재의 내부 공기층은 고려하지 않고 해석하였으며 해석에서 필요한 다겹보온자재의 물성치인 열전도도는 과도 열선법에 의해 측정되는 QTM-500을 사용하였다. 실험 결과, 조합형 보온자재가 단겹 보온자재에 비해 약 45~55%까지 보온율이 높았고, 조합조건에 따라 보온 효과가 달라지기 때문에 보온성이 우수한 조합 조건을 얻을 수 있을 것으로 예상된다. 수치해석 결과와 실험 결과와의 보온율을 비교해 보면 수치해석의 결과가 실험 결과의 보온율에 비해 다소 저하하는 경향을 나타내었는데 이는 다겹보온자재 내부의 공기층을 무시하여 나타난 오차로서 향후 보온자재 내부의 공기층을 고려할 경우 보다 정확한 수치해석 결과를 얻을 수 있을 것이다.