• 제목/요약/키워드: Bio-Housing

검색결과 61건 처리시간 0.028초

일회용 스트립형 효소면역센서용 플랫폼의 개발 (Development of Disposable Enzyme-linked Immunosensor Strip Platform)

  • 최지혜;이승재;장승철;김경천
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.400-405
    • /
    • 2011
  • This study introduced the development of a strip type disposable enzyme-linked immunosensor platform for the detection of IgG. Strips of the strip sensor were fabricated by using commercial nitrocellulose filter membranes and a housing holder for the strips was manufactured by using a standard injection molding process for a plastic material. An IgG-urease conjugate was prepared and used for the competitive immune-binding with sample IgG. From the enzymatic reaction between the conjugated urease and urea added, ammonia was generated and caused a localized alkaline pH change on the immobilized antibody band which was coated onto the sensor strips. This pH increase subsequently caused a color change of the antibody band in the presence of a pH indicator, phenol red. Used in conjunction with a competitive immunoassay format, the intensity of the color produced is directly linked with the concentration of target analyte, IgG, and specific measurement of IgG in a lateral flow immunoassay format was achieved over the range 100 ppb to 2000 ppb IgG.

국산 유용 수종의 오일열처리 연구 I - $200^{\circ}C$ 열처리 낙엽송과 오동나무 시편의 재색변화 - (Investigation on the Oil Heat Treatment of Domestic Utilization Species I - The Color Changes of Larch and Paulowniawood Specimens Treated at $200^{\circ}C$ -)

  • 강춘원;임호묵;강호양
    • 한국가구학회지
    • /
    • 제26권2호
    • /
    • pp.138-144
    • /
    • 2015
  • Among several thermal wood modification methods German oil heating technology was applied for color changing larch and paulowniawood specimens. They were heat treated at $200^{\circ}C$ for 3 hours in an autoclave filled with linseed oil. The CIE $L^*a^*b^*$ color indexes of the shells and cores of the oil heated specimens were measured. The color difference indexes between the oil heated and the control specimens of larch and paulowniawood were in the range of 6 and 12, which implies considerably different. The color difference indexes between the core layers of the larch and paulowniawood specimens were 4.3 and 1.7, respectively. It could be concluded that the specimens of the two species were color changed uniformly by oil heating.

Polyethylene Glycol 주입방법과 건조방법이 목재 부피수축률에 미치는 효과 (Effects of the Methods of Polyethylene Glycol Impregnation and Drying on the Volumetric Shrinkage of Wood)

  • 이원희;강춘원;홍승현;강호양
    • 한국가구학회지
    • /
    • 제27권1호
    • /
    • pp.43-48
    • /
    • 2016
  • PEG (Polyethylene glycol) impregnation in wood reduces the occurrence of checking during kiln drying. The volumetric shrinkages of wood PEG impregnated by pressure (PEG-P) or soaking (PEG-S) methods, and oven-dried by vent (VD) or air-tight (AD) methods were measured and compared with the controls. The average oven-dry weight of PEG impregnated specimens was larger than that of the controls by 3.6 g, but was not influenced by the drying methods. The average of the total volumetric shrinkage of PEG-P-VD specimens was the least (2.3%), while that of CON-S-AD specimens was the largest (28.9%). Within a drying method the total volumetric shrinkage of the control was the largest followed by PEG-S and PEG-P specimens, which implied that residual PEG in wood restrained its shrinkage during drying.

High-Temperature Drying of Bamboo Tubes Pretreated with Polyethylen Glycol Solution

  • Kang, Chun-Won;Chung, Woo-Yang;Han, Jae-Ok;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.139-146
    • /
    • 2017
  • This study was conducted to develop a new drying technology in order to quickly and massively dry bamboo tubes without crack and check. The bamboo tubes with the diameter of 45 mm - 68 mm had been impregnated in the solution of PEG-1000, and then were dried under room temperature and high temperature, respectively. The cracks occurred on all control specimens while no cracks were found on PEG treated specimens during drying at room temperature due to effect of PEG restraining the circumferential shrinkage of bamboo tube. But the drying period of this method was too long (200 days) compared to 10 hours of kiln drying. During fast high temperature drying, cracks occurred on all control specimens, but no cracks were found on PEG treated specimens, which could be accounted for more solidified PEG due to higher drying temperature and faster drying rate, and the tension set formed on the surface of bamboo tube in the early stage of drying owning to high drying temperature and low relative humidity. Thus, it is advised that PEG treated bamboo tube should be fast dried at high temperature in order to not only prevent crack or check in short drying period but also increase the dimensional stability of the products made of bamboo tubes.

도시유역의 물순환 및 수질 개선을 위한 저영향개발 시설의 비용 효율 분석 (Cost-Effectiveness Analysis of Low-Impact Development Facilities to Improve Hydrologic Cycle and Water Quality in Urban Watershed)

  • 최정현;김경민;심인경;이옥정;김상단
    • 한국물환경학회지
    • /
    • 제36권3호
    • /
    • pp.206-219
    • /
    • 2020
  • As urbanization and impermeable areas have increased, stormwater and non-point pollutants entering the stream have increased. Additionally, in the case of the old town comprising a combined sewer pipe system, there is a problem of stream water pollution caused by the combined sewer overflow. To resolve this problem, many cities globally are pursuing an environmentally friendly low impact development strategy that can infiltrate, evaporate, and store rainwater. This study analyzed the expected effects and efficiency when the LID facility was installed as a measure to improve hydrologic cycle and water quality in the Oncheon stream in Busan. The EPA-SWMM, previously calibrated for hydrological and water quality parameters, was used, and standard parameters of the LID facilities supported by the EPA-SWMM were set. Benchmarking the green infrastructure plan in New York City, USA, has created various installation scenarios for the LID facilities in the Oncheon stream drainage area. The installation and maintenance cost of the LID facility for scenarios were estimated, and the effect of each LID facility was analyzed through a long-term EPA-SWMM simulation. Among the applied LID facilities, the infiltration trench showed the best effect, and the bio-retention cell and permeable pavement system followed. Conversely, in terms of cost-efficiency, the permeable pavement systems showed the best efficiency, followed by the infiltration trenches and bio-retention cells.

방염처리가 톱밥-귤박 혼합파티클보드의 흡음성능에 미치는 영향 (Effect of Flame Resistant Treatment on The Sound Absorption Capability of Sawdust-mandarin Peel Composite Particleboard)

  • 강춘원;;강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권4호
    • /
    • pp.511-517
    • /
    • 2015
  • 방염처리에 의한 톱밥-귤박 혼합파티클보드의 방염성능과 흡음성능의 변화를 관찰하고자 톱밥과 귤박을 혼합하여 파티클보드를 제작하였다. 보드로부터 원반형 시험편을 제작하여 무처리 보드에 2마이크로폰 전달함수법으로 보드의 흡음률을 측정하고 동일한 시험편에 방염수지를 도포한 후 동일한 방법으로 흡음률을 측정하였다. 방염성능 시험은 무처리와 방염처리 톱밥-귤박 혼합파티클보드를 45도 연소챔버에서 연소하여 탄화면적을 비교하였다. 방염처리에 의해시험편의 중량은 6.3% 정도 증가하였으며 탄화면적은 46.7% 정도 감소하였다. 흡음률은 측정주파수범위(500-6,400 Hz) 에서 방염처리 시험편이 무처리 시험편보다 약간 낮게 나타났다. 무처리와 방염처리 톱밥-귤박 혼합파티클보드의 흡음성능은 측정주파수 영역에서 상용 석고보드(두께 11 mm)보다 우수한 흡음성능을 나타내어 비내력벽 등의 흡음판으로의 이용이 기대된다.

침지형 MBR 공정의 공기 세정 최적화를 통한 효율적 막 오염 제어 (Optimization of air scouring for an effective control of membrane fouling in submerged MBR)

  • 김준영;백병도;장인성
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.645-652
    • /
    • 2016
  • A membrane module including grid was designed and introduced to MBR (membrane bio-reactor) for the purpose of better control of membrane fouling. It could be anticipated that the grid enhances the shear force of fluid-air mixture into the membrane surface by even-distributing the fluid-air to the membrane module. As MLSS concentration, packing density which is expressed in the ratio of the housing and the cross-sectional area of membrane fibers ($A_m/A_t$) and air-flow rate were changed, membrane foulings were checked by monitoring fouling resistances. The total fouling resistance ($R_c+R_f$) without grid installation (i.e., control) was $2.13{\times}10^{12}m^{-1}$, whereas it was reduced to $1.69{\times}10^{12}m^{-1}$ after the grid was installed. Regardless of the grid installation, the $R_c+R_f$ increased as the packing density increased from 0.09 to 0.28, however, the increment of resistance for the grid installation was less than that of the control. Increase in the air flow rate did not always guarantee the reduction of fouling resistance, indicating that the higher air flow rate can partially de-flocculate the activated sludge flocs, which led to severer membrane fouling. Consequently, installation of grids inside the housing have brought a beneficial effect on membrane fouling and optimum air flow rate is important to keep the membrane lowering fouling.

온실 내 초분광 영상 취득 시 할로겐과 차광 커튼이 미치는 영향 (Effects of Halogen and Light-Shielding Curtains on Acquisition of Hyperspectral Images in Greenhouses)

  • 김태양;유찬석;강예성;장시형;박준우;강경석;백현찬;박민준;박진기
    • 한국농림기상학회지
    • /
    • 제23권4호
    • /
    • pp.306-315
    • /
    • 2021
  • 본 연구는 유리온실 내에서 초분광 영상을 취득하였을 때 차광 커튼과 할로겐이 DN value스펙트럼에 미치는 영향에 관한 것이다. 국립식량과학원 남부작물부 유리온실에 설치된 자동영상취득시스템을 이용하였으며 30° 기울어진 보정용 Tarp (1.4×1.4 m, 12%)를 설치한 후 하우징과 거리별(0.7~2.1 m) 영상데이터를 4가지 조건으로 3반복 취득했다. 차광 커튼과 할로겐을 모두 사용하지 않고 영상을 취득하였을 경우, 직달광부분과 그림자부분은 550 nm를 기준으로 스펙트럼의 변동성이 커졌다. 직달광부분과 그림자부분의 평균 변동계수(Coefficient of variation, CV)값은 각각 1.8%, 4.2%이며 그림자 유무에 관계없이 CV값을 계산 할 경우 12.5%로 증가되었다. 차광 커튼을 사용하지 않고 할로겐만을 이용한 경우 직달광부분과 그림자 부분의 CV 값은 2.6%, 10.6%이고 그림자 유무에 관계없이 CV 값을 계산할 경우 11.2%로 나타났으며 하우징과 거리에 따른 할로겐 보광량 차이로 인해 스펙트럼 변화폭이 증가되었다. 차광커튼만을 사용한 경우 CV 값은 1.6%이며 직달광과 그림자부분의 구분이 사라졌다. 차광 커튼과 할로겐을 모두 사용한 경우 하우징과 거리에 따른 할로겐의 보광량 차이로 CV 값은 10.2%로 증가했다. 할로겐과 차광 커튼을 모두 사용한 영상의 높이 범위 별 CV 값을 계산하였을 때 0.1 m 범위는 1.4%, 0.2 m범위는 1.9%, 0.3 m 범위는 2.6%, 0.4 m 범위는 3.3%로 나타났다. 따라서 온실에서 표준화된 영상데이터를 취득하기 위해서는 차광 커튼을 이용해 광을 균일하게 해야하고 할로겐램프를 이용해 보광 할 경우 대상의 수직 높이가 0.2 m 미만이며 대상과 하우징의 거리가 일정하게 유지 되었을 때 유효하다고 판단된다.

휴대용 유전율식 수분계를 이용한 목재의 전건밀도 추정 (Estimation of Wood Oven-Dry Density by Using a Portable Dielectric Moisture Meter)

  • 강춘원;임호묵;강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권5호
    • /
    • pp.629-639
    • /
    • 2017
  • 현재 합천 해인사에 보관되어 있는 고려속장경(일명 팔만대장경)은 역사적 가치나 규모면에 있어서 세계적인 문화재이나 아직도 어떤 수종으로 만들어졌는지 모르고 있다. 중요한 문화재이기 때문에 손상없이 비파괴적으로 수종을 추정하는 방법이 필요하다. 밀도를 알게 되면 수종을 추정하기 쉽다. 유전율식 목재수분계의 원리를 역으로 이용하면 함수율을 알고 있는 목재의 전건밀도를 얻을 수 있다는데 착안하여 연구를 수행하였다. 국내산 100여 개 수종, 122개 재감의 전건밀도를 치수법과 유전율식 목재수분계 추정법으로 구하여 두 계수의 상관관계와 회귀식을 찾았으며 문헌자료를 이용하여 회귀식의 유의성을 검정하였다. 치수법으로 측정한 전건밀도와 유전율식 목재수분계로 추정한 전건밀도는 매우 높은 상관관계를 나타냈다. 이 관계식을 이용하면 팔만대장경판의 전건밀도를 추정할 수 있으며 나아가 수종을 예측할 수 있을 것이다.

바이오디젤 원료용 유채 함수율 센서 개발 (Development of a Moisture Content Sensor for Rapeseed as Biodiesel Raw Material)

  • 이충근;최용;전현종;정광식
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.15-20
    • /
    • 2009
  • This study was conducted to develop a moisture sensor for rapeseed, a bio-diesel material. A typical rapeseed, SUNMANG, was used as a raw material. The rapeseed moisture content sensor consists of three components, such as upper and bottom electrodes, a test material dish, and a fixing housing. To evaluate the performance, a data acquisition system was equipped with the rapeseed moisture sensor, computer, printer, and main board. The findings of this study were: 1) the rapeseed moisture content was inversely proportional to electric resistance, and 2) values of electric resistance were recorded in a range of $10{\sim}100\;M{\Omega}$, depending upon a change of the moisture content. The determination of coefficient ($R^2$) and standard error between rapeseed moisture content and electric resistance were 0.9921 and ${\pm}0.289$, which indicated a highly correlative relationship. The response of rapeseed moisture sensor to temperature change was also observed for further performance test. Satisfying results were obtained, such as the determination of coefficient ($R^2$) of 0.9918, predicted standard error of ${\pm}0.373%$, deviation of 0.103%, measurement error of $0.14{\sim}0.48%$, standard deviation of $0.01{\sim}0.22%$, and measurement time of 28.3 s per point, respectively.