• Title/Summary/Keyword: Bio-Function

Search Result 793, Processing Time 0.026 seconds

Community Characteristics and Biological Quality Assessment on Benthic Macroinvertebrates of Bongseonsa Stream in Gwangneung Forest, South Korea (광릉숲 내 봉선사천의 저서성 대형무척추동물의 군집 특성 및 생물학적 하천평가)

  • Jung, Sang-Woo;Cho, Yong-Chan;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.6
    • /
    • pp.508-519
    • /
    • 2017
  • There have been many studies on monitoring of biodiversity changes and preservation of Gwangneung Forest Biosphere Reserve (GFBR) in South Korea in recognition of the rare ecosystem that has been preserved for a long period. However, there are few studies on diversity and community characteristics of benthic macroinvertebrates as an indicator of stream health of GFBR. The purpose of this study was to assess the water quality of Bongseonsa Stream that penetrated through Gwangneung Forest and the nearby torrents by analyzing the benthic macroinvertebrates community during April to September 2016. The investigation collected a total of 114 species of benthic macroinvertebrates belonging to 56 families, 17 orders, 8 classes, and 5 phyla from the Bongseonsa Stream and Kwangneung Stream. Ephemeroptera and Trichoptera were the largest groups in species diversity with 30 species (32.3%) and 16 species (17.2%), respectively, and Tubificidae sp., Baetis fuscatus, Antocha KUa, and Cheumatopsyche brevilineata, which usually habit in contaminated streams, appeared frequently. Among the feeding function groups, the gatherers and hunters appeared relatively frequently, and the shredders and scrapers appeared frequently in the torrents. Among the habitat oriented groups, the clingers and burrower appeared more frequently and represented the microhabitats in the shallow areas. The result of the analysis of benthic macroinvertebrates community showed that the dominant index was $0.48{\pm}0.10$ in average while it was lowest with 0.33 in GS 8 of the Gwangneung Forest torrent and highest in BS 1 of Bongseonsa Stream. The diversity and richness indices were inversely proportional to the dominant index and were 2.53 and 4.22, respectively, in GS 8 where the dominant index was low. The result of the analysis of community stability showed that area I, which had high resistance and restoration, was high in Bongseonsa Stream while the area III, which had low resistance and restoration, was high in Gwangneung Forest, indicating that the water system in Gwangneung Forest had a wider distribution of specifies sensitive to agitation. The biological water quality assessment showed ESB of $50.88{\pm}17.69$, KSI of $1.11{\pm}0.57$, and BMI of $78.55{\pm}11.05$. GS 8 of Gwangneung Forest torrent was judged to be the highest priority protective water area with the best water environment and I class water quality with ESB of 63, KSI of 0.55, and BMI of 89.9. On the contrary, BS 1 of Bongseonsa Stream was judged to be the high priority improvement area that had the lowest water quality rating of III with ESB of 25, KSI of 2.13, and BMI of 62.7. Although the diversity of water beetle was higher in the water system of nearby Bongseonsa Stream than the water system inside the Gwangneung Forest, the annual community structure appeared to have distinct differences.

DISEASE DIAGNOSED AND DESCRIBED BY NIRS

  • Tsenkova, Roumiana N.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1031-1031
    • /
    • 2001
  • The mammary gland is made up of remarkably sensitive tissue, which has the capability of producing a large volume of secretion, milk, under normal or healthy conditions. When bacteria enter the gland and establish an infection (mastitis), inflammation is initiated accompanied by an influx of white cells from the blood stream, by altered secretory function, and changes in the volume and composition of secretion. Cell numbers in milk are closely associated with inflammation and udder health. These somatic cell counts (SCC) are accepted as the international standard measurement of milk quality in dairy and for mastitis diagnosis. NIR Spectra of unhomogenized composite milk samples from 14 cows (healthy and mastitic), 7days after parturition and during the next 30 days of lactation were measured. Different multivariate analysis techniques were used to diagnose the disease at very early stage and determine how the spectral properties of milk vary with its composition and animal health. PLS model for prediction of somatic cell count (SCC) based on NIR milk spectra was made. The best accuracy of determination for the 1100-2500nm range was found using smoothed absorbance data and 10 PLS factors. The standard error of prediction for independent validation set of samples was 0.382, correlation coefficient 0.854 and the variation coefficient 7.63%. It has been found that SCC determination by NIR milk spectra was indirect and based on the related changes in milk composition. From the spectral changes, we learned that when mastitis occurred, the most significant factors that simultaneously influenced milk spectra were alteration of milk proteins and changes in ionic concentration of milk. It was consistent with the results we obtained further when applied 2DCOS. Two-dimensional correlation analysis of NIR milk spectra was done to assess the changes in milk composition, which occur when somatic cell count (SCC) levels vary. The synchronous correlation map revealed that when SCC increases, protein levels increase while water and lactose levels decrease. Results from the analysis of the asynchronous plot indicated that changes in water and fat absorptions occur before other milk components. In addition, the technique was used to assess the changes in milk during a period when SCC levels do not vary appreciably. Results indicated that milk components are in equilibrium and no appreciable change in a given component was seen with respect to another. This was found in both healthy and mastitic animals. However, milk components were found to vary with SCC content regardless of the range considered. This important finding demonstrates that 2-D correlation analysis may be used to track even subtle changes in milk composition in individual cows. To find out the right threshold for SCC when used for mastitis diagnosis at cow level, classification of milk samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two levels of SCC - 200 000 cells/$m\ell$ and 300 000 cells/$m\ell$, respectively, were set up and compared as thresholds to discriminate between healthy and mastitic cows. The best detection accuracy was found with 200 000 cells/$m\ell$ as threshold for mastitis and smoothed absorbance data: - 98% of the milk samples in the calibration set and 87% of the samples in the independent test set were correctly classified. When the spectral information was studied it was found that the successful mastitis diagnosis was based on reviling the spectral changes related to the corresponding changes in milk composition. NIRS combined with different ways of spectral data ruining can provide faster and nondestructive alternative to current methods for mastitis diagnosis and a new inside into disease understanding at molecular level.

  • PDF

Effect of Trace Metal on Accumulation and Physiological Response of the Polychaete, Perinereis nuntia (미량금속 노출에 따른 갯지렁이(Perinereis nuntia)의 미량금속 축적 및 생리학적인 반응)

  • Won, Eun-Ji;Ra, Kong-Tae;Hong, Seong-Jin;Kim, Kyung-Tae;Lee, Jae-Seong;Shin, Kyung-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.4
    • /
    • pp.288-295
    • /
    • 2010
  • Metal exposure experiments using polychaete (Perinereis nuntia) as a bio-indicator of trace metals contamination were conducted to evaluate the bioaccumulation and the biomarkers responses such as metallothionein-like protein (MTLPs) and glutathione S-transferase (GST) which was simultaneously exposed to Cadmium (Cd) and Copper (Cu). Cu and Cd concentrations in polychaete were enhanced with increasing exposure time and their concentrations of aqueous medium. Initial accumulation of Cd was higher than that of Cu. Our results showed that the bioaccumulation of Cu and Cd were prohibited, especially at higher Cu levels, suggesting the different cellular uptake mechanisms when Cu and Cd are co-exist. Net accumulation rate of Cu was declined with exposure time but it did not show any significant change for Cd. Although the highest MTLPs concentration was observed at 6 hr of exposure time, it did not show any significant change related to exposure times and metals concentrations. An increase of GST activity tended to increase as a function of exposure time and metals concentrations. And GST activities in P. nuntia have similar tendency with bioconcentration factors in high concentration of Cu (treatment group IV) at post 24 h of exposure. Our results provide new information of the bioaccumulation and biomarker responses to understand the effects of co-existing contaminants (Cu and Cd) using polychaete. Further studies are required to elucidate the bioaccumulation and biomarkers responses for various contaminants.

Proposal on for Response System to International Terrorism (국제 테러리즘의 대응체제 구축방안)

  • Suh, Sang-Yul
    • Korean Security Journal
    • /
    • no.9
    • /
    • pp.99-131
    • /
    • 2005
  • Terrorism which became today's common phenomena over the world is one of the most serious threats the world confront. Although International society make and operate outstanding anti-terrorism system, terror would never end without solving fundamental problems. The main body of terrorism converts from nation to organization and from organization to cell, which makes it difficult for us to recognize the main body. Since the target of today's new terrorism is many and unspecified persons, terrorists will never hesitate to use mass destruction weapons such as nuclear, biological, chemical weapons, and also use cyber-technique or cyber-terrorism. So, effective counter-terrorism measures should be performed as follows. First, it must be better for international society should make long-time plan of solving fundamental problems of terrorism other than to operate directly on terror organization and its means. Second, preventive method should be made. The most effective method of eradicating terrorism is prevention. For this, it is necessary to remove environmental elements of terrorism and terrorist bases, and to stop inflow of money and mass destruction weapons to terrorists. Third, integrated anti-terror organization should be organized and operated for continuous counter-terrorism operations. Also international alliance for anti-terrorism should be maintained to share informations and measures. Fourth, concerned department in the government should prepare counter-terrorism plans in their own parts as follows and make efforts to integrate the plans. - Ministry of Government Administration and Home Affairs : conventional terror - Ministry of Health and Welfare : bio-terror - Ministry of Science and Technology : nuclear-terror Especially, they should convert their policy and operation from post-terror actions to pre-terror actions, designate terror as national disaster and organize integrated emergency response organization including civil, government, and military elements. In conclusion, pre-terror activities and remedy of fundamental causes is the best way to prevent terror. Also, strengthening of intelligence activities, international cooperations, and preventive and comprehensive counter-measures must not ignored.

  • PDF

Diagnostic Classification of Chest X-ray Pneumonia using Inception V3 Modeling (Inception V3를 이용한 흉부촬영 X선 영상의 폐렴 진단 분류)

  • Kim, Ji-Yul;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.773-780
    • /
    • 2020
  • With the development of the 4th industrial, research is being conducted to prevent diseases and reduce damage in various fields of science and technology such as medicine, health, and bio. As a result, artificial intelligence technology has been introduced and researched for image analysis of radiological examinations. In this paper, we will directly apply a deep learning model for classification and detection of pneumonia using chest X-ray images, and evaluate whether the deep learning model of the Inception series is a useful model for detecting pneumonia. As the experimental material, a chest X-ray image data set provided and shared free of charge by Kaggle was used, and out of the total 3,470 chest X-ray image data, it was classified into 1,870 training data sets, 1,100 validation data sets, and 500 test data sets. I did. As a result of the experiment, the result of metric evaluation of the Inception V3 deep learning model was 94.80% for accuracy, 97.24% for precision, 94.00% for recall, and 95.59 for F1 score. In addition, the accuracy of the final epoch for Inception V3 deep learning modeling was 94.91% for learning modeling and 89.68% for verification modeling for pneumonia detection and classification of chest X-ray images. For the evaluation of the loss function value, the learning modeling was 1.127% and the validation modeling was 4.603%. As a result, it was evaluated that the Inception V3 deep learning model is a very excellent deep learning model in extracting and classifying features of chest image data, and its learning state is also very good. As a result of matrix accuracy evaluation for test modeling, the accuracy of 96% for normal chest X-ray image data and 97% for pneumonia chest X-ray image data was proven. The deep learning model of the Inception series is considered to be a useful deep learning model for classification of chest diseases, and it is expected that it can also play an auxiliary role of human resources, so it is considered that it will be a solution to the problem of insufficient medical personnel. In the future, this study is expected to be presented as basic data for similar studies in the case of similar studies on the diagnosis of pneumonia using deep learning.

Carbon Budget in Campus of the National Institute of Ecology (국립생태원 캠퍼스 내 주요 식생의 탄소수지)

  • Kim, Gyung Soon;Lim, Yun Kyung;An, Ji Hong;Lee, Jae Seok;Lee, Chang Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.167-175
    • /
    • 2014
  • This study was conducted to quantify a carbon budget of major vegetation types established in the campus of the National Institute of Ecology (NIE). Carbon budget was measured for Pinus thunbergii and Castanea crenata stands as the existing vegetation. Net Primary Productivity (NPP) was determined by applying allometric method and soil respiration was measured by EGM-4. Heterotrophic respiration was calculated as 55% of total respiration based on the existing results. Net Ecosystem Production (NEP) was determined by the difference between NPP and heterotrophic respiration (HR). NPPs of P. thunbergii and C. crenata stands were shown in $4.9ton\;C\;ha^{-1}yr^{-1}$ and $5.3ton\;C\;ha^{-1}yr^{-1}$, respectively. Heterotrophic respirations of P. thunbergii and C. crenata stands were shown in $2.4ton\;C\;ha^{-1}yr^{-1}$ and $3.5ton\;C\;ha^{-1}yr^{-1}$, respectively. NEPs of P. thunbergii and C. crenata stands were shown in $2.5ton\;C\;ha^{-1}yr^{-1}$ and $1.8ton\;C\;ha^{-1}yr^{-1}$, respectively. Carbon absorption capacity for the whole set of vegetation types established in the NIE was estimated by applying NEP indices obtained from current study and extrapolating NEP indices from existing studies. The value was shown in $147.6ton\;C\;ha^{-1}yr^{-1}$ and it was calculated as $541.2ton\;CO_2ha^{-1}yr^{-1}$ converted into $CO_2$. This function corresponds to 62% of carbon emission from energy that NIE uses for operation of various facilities including the glass domes known in Ecorium. This carbon offset capacity corresponds to about five times of them of the whole national territory of Korea and the representative rural area, Seocheongun. Considered the fact that ongoing climate change was originated from imbalance of carbon budget at the global level, it is expected that evaluation on carbon budget in the spatial dimension reflected land use pattern could provide us baseline information being required to solve fundamentally climate change problem.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Stress distribution of molars restored with minimal invasive and conventional technique: a 3-D finite element analysis (최소 침습적 충진 및 통상적 인레이 법으로 수복한 대구치의 응력 분포: 3-D 유한 요소 해석)

  • Yang, Sunmi;Kim, Seon-mi;Choi, Namki;Kim, Jae-hwan;Yang, Sung-Pyo;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.297-305
    • /
    • 2018
  • Purpose: This study aimed to analyze stress distribution and maximum von Mises stress generated in intracoronal restorations and in tooth structures of mandibular molars with various types of cavity designs and materials. Materials and Methods: Three-dimensional solid models of mandible molar such as O inlay cavity with composite and gold (OR-C, OG-C), MO inlay cavity with composite and gold (MR-C, MG-C), and minimal invasive cavity on occlusal and proximal surfaces (OR-M, MR-M) were designed. To simulate masticatory force, static axial load with total force of 200 N was applied on the tooth at 10 occlusal contact points. A finite element analysis was performed to predict stress distribution generated by occlusal loading. Results: Restorations with minimal cavity design generated significantly lower values of von Mises stress (OR-M model: 26.8 MPa; MR-M model: 72.7 MPa) compared to those with conventional cavity design (341.9 MPa to 397.2 MPa). In tooth structure, magnitudes of maximum von Mises stresses were similar among models with conventional design (372.8 - 412.9 MPa) and models with minimal cavity design (361.1 - 384.4 MPa). Conclusion: Minimal invasive models generated smaller maximum von Mises stresses within restorations. Within the enamel, similar maximum von Mises stresses were observed for models with minimal cavity design and those with conventional design.

Current status and prospects of approval of the new technology-based food additives (신기술이용 식품첨가물 국내·외 심사 현황 및 전망)

  • Rhee, Jin-Kyu
    • Food Science and Industry
    • /
    • v.52 no.2
    • /
    • pp.188-201
    • /
    • 2019
  • In the past, food additives were classified and managed as chemical synthetic and natural additives according to the manufacturing process, but it was difficult to confirm the purpose or function of food additives.CODEX, an internationalstandard, classifies food additives according to their practical use, based on scientific evidence on the technical effects of food additives, instead of classifying them as synthetic or natural. Therefore, very recently, the food additive standards in Korea have been completely revised in accordance with these global trends. Currently, the classification system of food additives is divided into 31 uses to specify their functions and purposes instead of manufacturing methods. Newer revision of the legislative framework for defining and expanding the scope of the Act as an enlarged area is required. Competition for preempting new food products based on bio-based technology is very fierce in order to enhance the safety of domestic people and maximize the economic profit of their own countries. In this age of infinite competition, it is very urgent to revise or supplement the current regulations in order to revitalize the domestic food industry and enhance national competitiveness through the development of food additives using new biotechnology. In this report, current laws on domestic food ingredients, food additives and manufacturing methods, and a comparison of domestic and foreign advanced countries' regulations and countermeasures strategies were reviewed to improve national competitiveness of domestic advanced biotechnology-based food additives industry.