• Title/Summary/Keyword: Bingham

Search Result 224, Processing Time 0.023 seconds

An Analysis of Debris Flow Movements Using Rheological Model (레올로지 모델을 이용한 토석류 이동해석)

  • 김상규;서흥석
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.133-144
    • /
    • 1997
  • It was proved from the viscosity test for deposits of debris flows(Kim and Seo, 1997) that the property of debris flows could be represented as Bingham plastic model. Based on this bahavior, numerical analysis for the movement of debris flows is carried out by using a computer progran Polyflow which huts been developed for the analysis of the behavior of non-Newtonian fluid. The numerical results obtained from two sites agree well with the movement predicted by an empirical formula. It can be concluded, therefore. that this scheme can be used for the analysis of the movement of debris flow.

  • PDF

Active Tension Control Using an ER Brake Actuator (ER브레이크 작동기를 이용한 능동 장력 제어)

  • Park, S.B.;Kim, G.W.;Cheong, C.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.102-111
    • /
    • 1996
  • This paper presents a proof-of-concept investigation on an active tension control using an ER (electro-rheological) brake actuator. Firstly, an ERF (electro-rheological fluid) which has an inherent reversible feature from Newtonian fluid to Bingham fluid upon applying an electric field is composed, and its property is tested to obtain intrinsic parameters of the Bingham model. An appropriate size of the ER brake is manufactured on the basis of the Bingham model, and dynamic characteristics of the brake are experimentally identified. After formulating a governing equation of motion of the tension control system, a sliding mode controller is designed to achieve a certain desired level of tension. Both simulation and experimental works are undertaken in order to demonstrate the efficiency and feasibility of the proposed active tension control method.

  • PDF

Control Performance Investigation of MR Fluid Damper using Herschel-Bulkley Shear Model (Herschel-Bulkley 모델을 이용한 MR 댐퍼 승용차의 제어 성능 고찰)

  • 이덕영;황우석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.323-328
    • /
    • 2002
  • The control performance of a vehicle installed with an MR(magnetorheological) fluid-based damper is investigated on the basis of Herschel-Bulkley shear model. Generally, most of MR fluid damper has been analyzed based on a simple Bingham-plastic shear model. However, the Bingham-plastic shear model can not well describe the behavior of the damper on the condition of high velocity and high current field input. Therefore, in this study, the Herschel-Bulkley shear model in which the constant post-yield plastic viscosity in Bingham model is replaced with a power law model dependent on shear rate is used to assess control performance of a vehicle with MR fluid damper suspension system. This study deals with a two-degree-of-freedom suspension using the MR fluid damper for a quarter car model. The response for the bump input to identify the fastness of MR fluid damper embedded skyhook controller and requested magnetic field are investigated.

  • PDF

The Flow Visualization of ER Fluid Between Two Parallel-Plate Electrodes Separated by Small Distance (좁은 평행평판전극 사이의 ER유체 유동의 가시화)

  • Park, Myeong-Kwan;Rhee, Eun-Jun;Oshima, Shuzo;Yamane, Ryuichiro
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.801-810
    • /
    • 1999
  • The purpose of present research was to get characteristics and basic knowledges of electrorheological(ER) suspension. To observe behaviors of the ER suspensions. transparent conductive plates were used to visualize the flow of ER suspensions between two parallel plate electrodes. The influence of flowing speed and intensity of electric field on the ER fluid were examined in circle-shaped electric field, and it takes several hundred milliseconds that suspensions in flow cluster. The present study also conducts a numerical analysis adopting the Bingham model. It is found that simple Bingham model can not property describe the flow behavior in the parallel plates.

Electrorheology of the Suspension Based on Chitosan Adipate as a New Anhydrous ER Fluid

  • Choi, Ung-Su;Ko, Young-Gun
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.142-145
    • /
    • 2001
  • The electrorheology of the chitosan adipnate suspension in silicone oil was investigated. Chitosan adipnate suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the chitosan adipnate suspension exhibited a linear dependence on the volume fraction of particles and an electric field power of 1.88. The experimental results for the chitosan adipnate suspension correlated with the conduction models and this suspension was found to be an anhydrous ER fluid.

  • PDF

Shear stress analysis of phosphorylated potato starch based electrorheological fluid

  • Hong, Cheng-Hai;Choi, Hyoung-Jin
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Electrorheological characteristics of a dispersed system of phosphorylated potato starch particles in silicone oil investigated via a rotational rheometer equipped with a high voltage generator is being reanalysized. Flow curves of these ER fluids both under several applied electric field strengths and with different degrees of phosphate substitution were mainly examined via three different rheological constitutive equations of Bingham model, De Kee-Turcotte model and our previously proposed CCJ model. Among these, the CCJ equation was found to fit the data of phosphorylated potato starch well.

Electrorheology of Chitosan Suspension by Conduction Models (전도성 모델에 의한 키토산 현탁액의 유변학적 특성 연구)

  • 최웅수;안병길;이상순;권오관
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.95-99
    • /
    • 1998
  • The electrorheological (ER) behavior of chitosan suspension in the silicone oil was investigated. Chitosan suspension showed a typical ER response, Bingham flow behavior upon application of an electric field due to the polarizability of the branched amino group of the chitosan particles. The shear yield stress exhibited a linear dependence on the volume fraction of particles and the squared electric field. On the basis of the experimental results, chitosan suspension has been correlated with the conduction models for ER response and found to be an ER fluid.

Electrorheology of Hollow Polyaniline Pimelate Suspension by Conduction Model

  • Choi Ung-Su
    • KSTLE International Journal
    • /
    • v.7 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • The electro rheological behavior of the hollow polyaniline pimelate suspension in silicone oil was investigated. Hollow polyaniline pimelate suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 0.84 power on the electric field. The experimental results for the hollow polyaniline pimelate suspension correlated with the conduction models of Tang et al., and this suspension behaved as an ER fluid.

Electrorheological Properties of Cellulose Phosphate Ester Suspension by Conduction Models (전도성 모델에 의한 인산에스테르셀룰로오즈 현탁액의 전기유변학적 특성 연구)

  • 최웅수;고영건;박용성;권오관
    • Tribology and Lubricants
    • /
    • v.17 no.2
    • /
    • pp.124-129
    • /
    • 2001
  • The electrical and rheological behaviors of the cellulose phosphate ester suspension in the silicone oil were investigated. Cellulose phosphate ester suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the cellulose phosphate ester suspension exhibited a linear dependence on the volume fraction of particles and a square power of the electric field. On the basis of the experimental results, cellulose phosphate ester suspension correlated with the conduction model of Tang et al, and found to be an ER fluid.

Rheology of Hollow Polyaniline Gutarate Suspension Under DC Electric Field

  • Choi, Ung-Su
    • KSTLE International Journal
    • /
    • v.9 no.1_2
    • /
    • pp.36-38
    • /
    • 2008
  • The electrical and rheological behavior of the hollow polyaniline glutarate suspension in silicone oil was investigated. Hollow polyaniline glutarate suspension showed a typical ER response (Bingham flow behavior) under a DC electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 0.95 power on the electric field. The experimental results for the hollow polyaniline glutarate suspension behaved as an ER fluid.