• Title/Summary/Keyword: Bending-under-tension

Search Result 145, Processing Time 0.021 seconds

A Study on the Evaluation of Corrosion Resistance of Coated Steel Using Polymer Dispersion (폴리머 디스퍼션을 이용한 강재의 내식성 평가에 관한 연구)

  • Jo, Young-Kug
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.103-109
    • /
    • 2003
  • Reinforced concrete structures under sever conditions such as marine structures, bridges and structural constructed with aggregated(dredged front sea). can be deteriorated from corrosion of the reinforcing bars. The purpose of this study is to evaluate the corrosion reflectance of coated steel using polymer dispersion and polymer cement slurry. Polymer dispersion and polymer cement slurry with various polymer types were coated to the surface of bars and steel plate, and tested for accelerated corrosion tests. Tests include adhesion in tension, bending test, chloride ion spray, penetration of NaCl 10% solution and carbonation. From the test results, the corrosive resistance of steel is considerably improved by using polymer dispersion and polymer cement flurry at surface of steel. The difference of the corrosive resistance is hardly recognized according to types of polymer dispersion. The coated steel using polymer dispersion and polymer foment slurry will be improved to a great extent compared to those of plain steel when increasing content of chloride ion in cement concrete.

Riser Configuration Design for a 15-MW Floating Offshore Wind Turbine Integrated with a Green Hydrogen Facility

  • Sung-Jae Kim;Sung-Ju Park
    • Journal of Ocean Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.137-147
    • /
    • 2024
  • Green hydrogen presents a sustainable and environmentally friendly solution for clean energy production and transportation. This study aims to identify the optimal profile of green hydrogen transportation risers originating from a floating offshore wind turbine (FOWT) integrated with a hydrogen production facility. Employing the Cummins equation, a fully coupled dynamic analysis for FOWT with a flexible riser was conducted, with the tower, mooring lines, and risers described using a lumped mass line model. Initially, motion response amplitude operators (RAOs) were compared with openly published results to validate the numerical model for the FOWT. Subsequently, a parametric study was conducted on the length of the buoyancy module section and the upper bare section of the riser by comparing the riser's tension and bending moment. The results indicated that as the length of the buoyancy module increases, the maximum tension of the riser decreases, while it increases with the lengthening of the bare section. Furthermore, shorter buoyancy modules are expected to experience less fatigue damage, with the length of the bare section having a relatively minor impact on this phenomenon. Consequently, to ensure safety under extreme environmental conditions, both the upper bare section and the buoyancy module section should be relatively short.

Stress analysis of high-temperature superconducting wire under electrical/magnetic/bending loads

  • Dongjin Seo;Yunjo Jung;Hong-Gun Kim;Hyung-Seop Shin;Young-Soon Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.19-23
    • /
    • 2023
  • The Second-generation high-temperature superconducting (HTS) Rare-Earth Barium Copper Oxide (REBCO) wire is a composite laminate having a multi-layer structure (8 or more layers). HTS wires will undergo multiple loads including the bending-tension loads during winding, high current density, and high magnetic fields. In particular, the wires are subjected to bending stress and magnetic field stress because HTS wires are wound around a circular bobbin when making a high-field magnetic. Each of the different laminated wires inevitably exhibits damage and fracture behavior of wire due to stress deformation, mismatches in thermal, physical, electrical, and magnetic properties. Therefore, when manufacturing high-field magnets and other applications, it is necessary to calculate the stress-strain experienced by high-temperature superconducting wire to present stable operating conditions in the product's use environment. In this study, the finite element model (FEM) was used to simulate the strain-stress characteristics of the HTS wire under high current density and magnetic field, and bending loads. In addition, the result of obtaining the neutral axis of the wire and the simulation result was compared with the theoretical calculation value and reviewed. As a result of the simulation using COMSOL Multiphysics, when a current of 100 A was applied to the wire, the current value showed the difference of 10-9. The stress received by the wire was 501.9 MPa, which showed a theoretically calculated value of 500 MPa and difference of 0.38% between simulation and theoretical method. In addition, the displacement resulted is 30.0012 ㎛, which is very similar to the theoretically calculated value of 30 ㎛. Later, the amount of bending stress by the circular mandrel was received for each layer and the difference with the theoretically obtained the neutral axis result was compared and reviewed. This result will be used as basic data for manufacturing high-field magnets because it can be expanded and analyzed even in the case of wire with magnetic flux pinning.

Prediction of the Rupture of Circular Sections of Reinforced Concrete and Fiber Reinforced Concrete

  • Adjrad, A.;Bouafia, Y.;Kachi, M.S.;Ghazi, F.
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.3
    • /
    • pp.373-381
    • /
    • 2016
  • As part of this study, has been developed a numerical method which allows to establish abacuses connecting the normal force with bending moment for a circular section and therefore to predict the rupture of this type of section. This may be for reinforced concrete (traditional steel) or concrete reinforced with steel fibers. The numerical simulation was performed in nonlinear elasticity up to exhaustion of the bearing capacity of the section. The rupture modes considered occur by plasticization of the steel or rupture of the concrete (under compressive stresses or tensile stresses). Regarding the fiber-reinforced concrete, the rupture occurs, usually, by tearing of the fibers. The behavior laws of the different materials (concrete and steel) correspond to the real behavior. The influence of several parameters was investigated, namely; diameter of the section, concrete strength, type of steel, percentage of reinforcement and contribution of concrete in tension between two successive cracks of bending. A comparison was made with the behavior of a section considering the conventional diagrams of materials; provided by the BAEL rules. A second comparative study was performed for fibers reinforced section.

A Comparison Study of Structure Behavior of Flexible Riser Using Numerical and Theoretical Methods (유연식 라이저에 대한 유한요소법과 이론적 방법에 의한 구조 거동의 비교 연구)

  • Yim, Ki-Ho;Jang, Beom-Seon;Yoo, Dong-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.4
    • /
    • pp.258-265
    • /
    • 2016
  • A flexible riser consists of several layers which have different materials, shapes and functions. The layers designed properly can take the design load safely, and each property of layer provides a complexity of flexible riser. Such complexity/unit-property is an input for global analysis of flexible riser. There are several approaches to calculate the complexity of flexible riser, those are experimental, numerical and theoretical methods. This paper provides a complexity from numerical and theoretical analysis for 2.5 inch flexible riser of which details and the experimental data are already produced under tension, external pressure, and bending moment. In addition, comparison of stiffness and stress are also provided. Especially, analysis of stress could lead to researches on ultimate strength or fatigue strength of flexible risers.

Mechanical Properties and Garment Formability of PET/Spandex Stretch Fabrics (PET/스판덱스 스트레치 직물의 역학특성과 의류형성성능)

  • Kim, Hyunah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.6
    • /
    • pp.1098-1108
    • /
    • 2017
  • This paper investigated stretchability with fabric mechanical properties of one-way and two-way stretch fabrics. For this purpose, 1-way and 2-way woven fabrics were prepared using 150d PET/spandex covered yarns with different thermal treatment according to 4 kinds of wet thermal machines subsequently, fabric mechanical properties were measured and compared with regular PET fabrics. In addition, the garment formability of stretch fabrics was predicted and compared to regular fabrics according to wet thermal treatment. The weft stretchability of 2-way stretch fabric was about 10% higher than the 1-way stretch fabric. The compressibility of the stretch fabrics was 1.5 times higher than regular fabrics. The compressibility of stretch fabrics treated with CPB and rope type wet thermal machine showed higher values than other types of wet thermal machines. The bending rigidity of 2-way stretch fabric was lower than 1-way stretch fabric. Shear rigidity of 2-way stretch fabric was higher than 1-way and regular fabrics. Garment formability of 2-way stretch fabric was higher than regular and one-way stretch fabrics. Garment formability of 2-way stretch fabrics treated with wet thermal conditions under low tension showed the highest values.

Mechanical behavior and simplified models for the post-tensioned prestressed concrete lining

  • Fan Yang;Kang Liu;Yan-qiao Wang;Ming Huang
    • Structural Engineering and Mechanics
    • /
    • v.86 no.1
    • /
    • pp.17-27
    • /
    • 2023
  • To investigate the mechanical behavior of the post-tensioned prestressed concrete lining (PPCL), the desilting tunnel of the Xiaolangdi Hydro Project in China is adopted as a case, and a detailed three-dimensional continuum model verified by the observation results is established for the PPCL. The radial stresses, longitudinal stresses, axial forces and bending moments of the PPCL under the completed cable tension condition (CCTC) and design water pressure condition (DWPC) are analyzed, respectively. The numerical results reveal that the PPCL concrete is significantly compressed in the circumferential direction by the prestress, while the prestress has a negligible influence on the radial stresses of the PPCL concrete. It should be noted that the concrete near the anchor slots has a complex and adverse stress state with stress concentration, longitudinal tensioning and large bending moment. In addition, a simplified shell model and a further simplified beam model which can take the influences of the prestress loss and the anchor slot into consideration are proposed for the PPCL. The results of the simplified models are in a good agreement with these of the three-dimensional continuum model, and they can be used as efficient approaches for the structural design and analysis of the PPCL.

Effect of the GFRP wrapping on the shear and bending Behavior of RC beams with GFRP encasement

  • Ozkilic, Yasin Onuralp;Gemi, Lokman;Madenci, Emrah;Aksoylu, Ceyhun;Kalkan, İlker
    • Steel and Composite Structures
    • /
    • v.45 no.2
    • /
    • pp.193-204
    • /
    • 2022
  • The need for establishing the contribution of pultruded FRP encasements and additional FRP wraps around these encasements to the shear strength and load-deflection behavior of reinforced concrete beams is the main motivation of the present study. This paper primarily focuses on the effect of additional wrapping around the composite beam on the flexural and shear behavior of the pultruded GFRP (Glass Fiber Reinforced Polymer) beams infilled with reinforced concrete, taking into account different types of failure according to av/H ratio (arch action, shear-tension, shear-compression and pure bending). For this purpose, nine hybrid beams with variable shear span-to-depth ratio (av/H) were tested. Hybrid beams with 500 mm, 1000 mm, and 1500 mm lengths and cross-sections of 150x100 mm and 100x100 mm were tested under three-point and four-point loading. Based on the testing load-displacement relationship, ductility ratio, energy dissipation capacity of the beams were evaluated with comprehensive macro damage analysis on pultruded GFRP profile and GFRP wrapping. The GFRP wraps were established to have a major contribution to the composite beam ductility (90-125%) and strength (40-75%) in all ranges of beam behavior (shear-dominated or dominated by the coupling of shear and flexure). The composite beams with wraps were showns to reach ductilities and strength values of their counterparts with much greater beam depth.

Anlysis and Design of Wale in Innovative Prestressed Support(IPS) System (혁신적 프리스트레스트 가시설(IPS)공법에 적용되는 띠장의 설계 및 해석)

  • Kim, Sung-Bo;Han, Man-Yop;Kim, Moon-Young;Kim, Nak-Kyung;Ji, Tea-Sug
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.1
    • /
    • pp.79-91
    • /
    • 2005
  • The behaviors and design procedures of wale in innovative prestressed support(IPS) system are presented in this paper. Using the theory of the beam on elastic foundation, the member forces of the wale under initial pretension are evaluated. Choosing cable tensions as redundant forces, member forces subjected to earth pressure are calculated by the statically indeterminate analysis. The computer analysis model under uniform and non-uniform earth pressure is constructed using beam element for the IPS wale, tension-only element for cable, and compression-only element for soil. Axial forces and bending moments of IPS wale under initial pretension and design earth pressure are calculated. The combined stresses due to these axial force and bending moment are estimated to satisfy the design formula.

Strain distribution between CFRP strip and concrete at strengthened RC beam against shear

  • Anil, Ozgur;Bulut, Nalan;Ayhan, Murat
    • Structural Engineering and Mechanics
    • /
    • v.41 no.4
    • /
    • pp.509-525
    • /
    • 2012
  • In recent years, CFRP material usage in strengthening applications gradually became widespread. Especially, the studies on the strengthening of shear deficient reinforced concrete beams with CFRP strips are chosen as a subject to numerous experimental studies and research on this subject are increased rapidly. The most important variable, that is affected on the failure mode of CFRP strips and that is needed for determining the shear capacity of the strengthened reinforced concrete beams, is the strain distribution between CFRP strips and concrete. Numerous experimental studies are encountered in the literature about the determination of strain distribution between CFRP strips and concrete. However, these studies mainly focused on the CFRP strips under axial tension. There are very limited numbers of experimental and analytic studies examining the strain distribution between concrete and CFRP strips, which are under combined stresses due to the effects of shear force and bending moment. For this reason, existing experimental study in the literature is used as model for ANSYS finite element software. Nonlinear finite element analysis of RC beams strengthened against shear with CFRP strips under reverse cyclic loading is performed. The strain distributions between CFRP strips and concrete that is obtained from finite element analysis are compared with the results of experimental measurements. It is seen that the experimental results are consisted with the results derived from the finite element analysis and important findings on the strain distribution profile are reached by obtaining strain values of many points using finite element method.