• Title/Summary/Keyword: Beer-Lambert's law

Search Result 20, Processing Time 0.026 seconds

Calculation of Light Penetration Depth in Photobioreactors

  • Lee, Choul-Gyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.4 no.1
    • /
    • pp.78-81
    • /
    • 1999
  • Light penetration depth in high-density Chlorella cultures can be successfully estimated by Beer-Lambert's law. The efficiency of light energy absorption algal cultures was so high that algal cells near the illuminating surface shade the cells deep in the culture. To exploit the potential of high-density algal cultures, this mutual shading should be eliminated or minimized. However, providing more light energy will not ease the situation and it will simply drop the overall light utilization efficiency.

  • PDF

A Study on Structural-Thermal-Optical Performance through Laser Heat Source Profile Modeling Using Beer-Lambert's Law and Thermal Deformation Analysis of the Mirror for Laser Weapon System (Beer-Lambert 법칙을 적용한 레이저 열원 프로파일 모델링 및 레이저무기용 반사경의 열변형 해석을 통한 구조-열-광학 성능 연구)

  • Hong Dae Gi
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.4
    • /
    • pp.18-27
    • /
    • 2023
  • In this paper, the structural-thermal-optical performance analysis of the mirror was performed by setting the laser heat source as the boundary condition of the thermal analysis. For the laser heat source model, the Beer-Lambert model considering semi-transparent optical material based on Gaussian beam was selected as the boundary condition, and the mechanical part was not considered, to analyze the performance of only the mirror. As a result of the thermal analysis, thermal stress and thermal deformation data due to temperature change on the surface of the mirror were obtained. The displacement data of the surface due to thermal deformation was fitted to a Zernike polynomial to calculate the optical performance, through which the performance of the mirror when a high-energy laser was incident on the mirror could be predicted.

ETIR and Raman Spectroscopic Studies of Crystallization and Polymorphism of Syndiotactic Polystyrene (FTIR과 라만 분광 실험을 이용한 신디오탁틱 폴리스티렌의 구조 및 결정화 연구)

  • ;;;;;Kohji Tashiro
    • Polymer(Korea)
    • /
    • v.27 no.6
    • /
    • pp.603-608
    • /
    • 2003
  • Syndiotactic polystyrene (s-PS) presents a very complex polymorphic behavior depending on the sample preparation history and exhibits a solid-solid phase transition. Each different polymorphic structures of the s-PS sample were prepared by annealing the samples from room temperature to 220 $^{\circ}C$. The structural changes induced by annealing were investigated using FTIR and FT-Raman spectroscopy. Although the crystallization kinetics of s-PS are difficult to investigate with DSC due to its fast crystallization rate, it was possible to determine crystallinity changes in the s-PS sample using infrared characteristic peaks with Beer-Lambert's law.

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.

Study of Optical Tomography for Measurement of Spray Characteristics at High Ambient Pressure (고압 환경에서의 분무 특성 계측을 위한 광학 토모그래피 기법 연구)

  • Cho, Seong-Ho;Im, Ji-Hyuk;Choi, Ho-Yeon;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.4
    • /
    • pp.36-44
    • /
    • 2009
  • Spray cross-section was measured by the Optical Line Patternator (OLP) and Optical Tomography at high ambient pressure. The laser line beam passed through the spray region, then Mie scattered signal and transmitted light were captured. The measured signal was processed to obtain a distribution of attenuation coefficient in spray cross-section. Beer-Lambert's law and mathematical reconstruction methods were used to reconstruct the distribution of attenuation coefficient. Spray became dense at high pressure and attenuation of scattered signal occurred seriously. OLP method, which uses Mie scattered signal, showed limit in compensating attenuation problem in dense spray region. Optical tomography reconstructed spray cross-section well, from transmission rate of light penetrating spray region.

Determination of Microquantities of Nicotine (니코틴의 미량 정량법)

  • 김찬호;김신일
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.3 no.2
    • /
    • pp.77-81
    • /
    • 1981
  • A flew spectroscopic method was developed to determine microquantities of nicotine with cyanogen chloride and pyrazolon. Absorption maximum of tile derivative solution appeared at 520nm. The color formed in the proposed method was stable for at least 30 min. at pH 7.5, and followed the Lambert-Beer's law between tile limits of 1 and 5 micrograms of nicotine. The relative errors in burley and flue-cured tobacco leaves were $\pm5%$ in comparison with the Griffith method.

  • PDF

Algorithm for reduction of motion artifact generated in SpO2 measurement (산소포화도(SpO2) 측정시에 발생되는 motion artifact를 reduction하는 algorithm)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.860-863
    • /
    • 2003
  • Pulse oximetry has gained wide spread clinical acceptance in the latter part of the 21st century. The principle of pulse oximetry is based on the red and infrared light absorption features and uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow. There are two methods of sending light through the measuring site : transmission and reflectance. After the transmitted red and infrared signals pass through the measuring site and received at the photodetector, the red/infrared ratio is calculated. But, pulse of oximeters are so sensitive that they may detect pulses when pressure is too low to provide adequate tissue blood flow, that is, SpO2 may decrease due to O2 consumption by the finger of the pulsing but stagnant arterial blood at low pressure or with vasoconstriction. This project has the limitations of pulse oximetry. Therefore, this paper is focused on the resuction of motion artifact that caused by moving when someone measures with SpO2 system.

  • PDF

Isolative Determination of Ethinyl Estradiol and Norethindrone Acetate in the Mixed Preparations (혼합성분중(混合成分中) Ethinyl Estradiol과 Norethindrone Acetate의 분리정량(分離定量))

  • Lee, Jung-Hyun;Young, Jae-Ick
    • Journal of Pharmaceutical Investigation
    • /
    • v.1 no.1
    • /
    • pp.47-52
    • /
    • 1971
  • Application of the spectrophotometer to the analysis of 17 ${\alpha}-ethinyl$ estradiol and $17{\alpha}-ethinyl-19-nortestosterone$ acetate mixture in oral contraceptive has been accomplished. It is used Beckman Du Spectrophotometer as a apparatus. The petroleum ether extract of ethinyl estradiol is determined at $535\;m{\mu}$ and the chloroform extract of norethindrone acetate is determined at $380\;m{\mu}$ respectively. This analytical method is formed Lambert Beer's law. This method can be used to the analysis of ethinyl estradiol aid norethindrone acetate mixture in commercial dosage form of routine assay.

  • PDF

Steady-State and Transient Response Analysis of DSSC Based on Electron Diffusion Coefficient and Chemical Capacitance

  • J. C. Gallegos;J. Manriquez;R. Rodriguez;S. Vargas;D. Rangel
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.276-290
    • /
    • 2024
  • A study of the transition from transitory state to steady state in DSSCs based on natural dyes is presented; cochineal was used as dye and Li+, Na+, and K+ were the ions added to the electrolyte. The photocurrent profiles were obtained as a function of time. Several DSSCs were prepared with different cations and their role and the transitory-to-steady transition was determined. A novel hybrid charge carrier source model based on the Heaviside function H(t) and the Lambert-Beer law, was developed and applied to analysis of the transient response of the output photocurrent. Additionally, the maximum effective light absorption coefficient α and the electronic extraction rate κ for each ion were determined: ${\alpha}_{Li^+,Na^+,K^+}\,=\,(0.486,\,0.00085,\,0.1126)\,cm^{-1}$, and also the electronic extraction rate ${\kappa}^{Li^+,Na^+,K^+}_{ext.}\,=\,(1410,\,19.07,\,19.69)\,cm\,s^{-1}$. The impedance model using Fick's second law was developed for carrier recombination to characterize the photocurrent.

Electrical Characteristic and Optical Diagnosis for Atmospheric Direct Plasma Jet

  • Hong, Seong In;Ghimire, B.;Hong, Young Jun;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.155.1-155.1
    • /
    • 2015
  • Nowadays, Plasma has been used in biological, medical such as wound healing, plant grow, killing cancer. When plasma generated, UV light and ROS(Reactive oxygen species), RNS(Reactive nitrogen species) can generated and those things effect to biological material. So we made simple plasma device using needle type of electrode and generated plasma. We used three kinds of gas and measured applied voltage and current. Also we observed optical emission spectrum. Using deuterium ramp, we can observed absorption spectrum and calculated radical density by lambert-beer's law. It is around ~1016cm3. And we can see the time-resolved absorption spectrum from monochromator, PMT(photo multiply tube), IV-converter, oscilloscope.

  • PDF