• Title/Summary/Keyword: Bed Pressure

Search Result 540, Processing Time 0.032 seconds

Open Heart Surgery of Congenital Heart Diseases -Report of Four Cases- (선천성심질환(先天性心疾患)의 심폐기(心肺器) 개심수술(開心手術) - 4례(例) 보고(報告) -)

  • Kim, Kun Ho;Park, Young Kwan;Jee, Heng Ok;Kim, Young Tae;Rhee, Chong Bae;Chung, Yun Chae;Oh, Chull Soo
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • The present. study reports four cases of congenital heart diseases, who received open heart surgery by the Sarn's Heart-Lung-Machine in the department of Thoracic Surgery, Hanyang University Hospital during the period between July 1975 and May 1976. The Heart-Lung-Machine consisted of the Sarn's five head roller pump motor system (model 5000), heat exchanger, bubble trap, the Rygg-Kyvsgaard oxygenator, and monitors. The priming of pump oxygenator was carried out by the hemodilution method using Hartman's solution and whole blood. Of the four cases of the heart diseases, three whose body weight were below 30kg, received the partial hemodilution priming and the remaining one whose body weight was 52kg received the total hemodilution priming with Hartman's solution alone. The rate of hemodilution was in the average of 60.5ml/kg. Extracorporeal circulation was performed at the perfusion flow rate of the average 94.0ml/kg/min, and at the moderate hypothermia between 35'5"C and 30'5"C of the rectal temperature. In the total cardiopulmonary bypass, arterial blood pressure was anged between 30 mmHg and 85 mmHg, generally maintaining over 60 mmHg and venous pressure was measured between 4 and $23cmH_2O$, generally maintaining below $10cmH_2O$. The first case: The patient, a nine year old girl having the symptoms and physical signs typical to cardiac anomaly was definitely diagnosed as isolated pulmonary stenosis through the cardiac catheterization. There was, however, no cyanosis, no pathological finding by X-ray and E.C.G. tracings. The valvulotomy was performed through the arteriotomy of pulmouary artery under the total cardiopulmonary bypass. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The second case: A 12 year old boy with congenital heart anomaly was positively identified as having ventricular septal defect through the cardiac catheterization. As in the case with the first case, the patient exhibited the symptoms and physical signs typical to cardiac anomaly, but no pathological abnormality by X-ray and E.C.G. tracings. The septal defect was localized on atrioventricular canal and was 2 by 10 mm in size. The septal defect was closed by direct simple sutures under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle and pulmonary artery were decreased satisfactory. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The third case: The patient, a 19 year old girl had been experienced the clinical symptoms typical to cardiac anomaly for 16 years. The pink tetralogy of Fallot was definitey diagnosed through the cardiac catheterization. The patient was placed on an ablolute bed rest prior to the operation because of severe exertional dyspnea, fatigability, and frequent syncopal attacks. However, she exhibited very slight cyanosis. Positive findings were noted on E.C.G. tracings and blood picture, but no evidence of pathological abnormality on X-ray was observed. All of the four surgical approaches such as Teflon patch closure (3 by 4cm in size) of ventricular septal defect, myocardial resection of right ventricular outflow tract, valvulotomy of pulmonary valvular stenosis, and pericardial patch closing of ventriculotomy wound were performed in 95 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The fourth case: The patient, a 7 1/4 year old girl had the symptoms of cardiac anomaly for only three years prior to the operation. She was positively identified as having acyanotic tetralogy of Fallot by open heart surgery. The patient showed positive findings by X-ray and E.C.G. tracings, but exhibited no cyanosis and normal blood picture. All of the three surgical approaches, such a myocardial resection of hypertrophic sight ventricular outflow tract, direct suture closing of ventricular septal defect and pericardial patch closing of ventriculotomy wound were carried out in 110 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and the symptoms disappeared.

  • PDF

A study on the engineering optimization for the commercial scale coal gasification plant (상용급 석탄가스화플랜트 최적설계에 관한 연구)

  • Kim, Byeong-Hyeon;Min, Jong-Sun;Kim, Jae-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.131.1-131.1
    • /
    • 2010
  • This study was conducted for engineering optimization for the gasification process which is the key factor for success of Taean IGCC gasification plant which has been driven forward under the government support in order to expand to supply new and renewable energy and diminish the burden of the responsibility for the reduction of the green house gas emission. The gasification process consists of coal milling and drying, pressurization and feeding, gasification, quenching and HP syngas cooling, slag removal system, dry flyash removal system, wet scrubbing system, and primary water treatment system. The configuration optimization is essential for the high efficiency and the cost saving. For this purpose, it was designed to have syngas cooler to recover the sensible heat as much as possible from the hot syngas produced from the gasifier which is the dry-feeding and entrained bed slagging type and also applied with the oxygen combustion and the first stage cylindrical upward gas flow. The pressure condition inside of the gasifier is around 40~45Mpg and the temperature condition is up to $1500{\sim}1700^{\circ}C$. It was designed for about 70% out of fly ash to be drained out throughout the quenching water in the bottom part of the gasifier as a type of molten slag flowing down on the membrane wall and finally become a byproduct over the slag removal system. The flyash removal system to capture solid particulates is applied with HPHT ceramic candle filter to stand up against the high pressure and temperature. When it comes to the residual tiny particles after the flyash removal system, wet scurbbing system is applied to finally clean up the solids. The washed-up syngas through the wet scrubber will keep around $130{\sim}135^{\circ}C$, 40~42Mpg and 250 ppmv of hydrochloric acid(HCl) and hydrofluoric acid(HF) at maximum and it is turned over to the gas treatment system for removing toxic gases out of the syngas to comply with the conditions requested from the gas turbine. The result of this study will be utilized to the detailed engineering, procurement and manufacturing of equipments, and construction for the Taean IGCC plant and furthermore it is the baseline technology applicable for the poly-generation such as coal gasification(SNG) and liquefaction(CTL) to reinforce national energy security and create new business models.

  • PDF

Effects of Operating Variables on Sorption Capacity of CO2 Absorbents for SEWGS Process (SEWGS 공정용 CO2 흡수제들의 흡수능력에 미치는 조업변수들의 영향)

  • Ryu, Ho-Jung;Kim, Hyo-Sung;Lee, Seung-Yong;Lee, Dong-Ho;Kim, Jae-Chang
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.994-1001
    • /
    • 2012
  • The Effects of operating variables on reactivity of two $CO_2$ absorbents (PKM1-SU and P4-600) for SEWGS process were investigated in a pressurized fluidized bed reactor. For both $CO_2$ absorbents, $CO_2$ sorption capacity decreased as the number of absorption-regeneration cycles increased. PKM1-SU absorbent represented higher $CO_2$ sorption capacity than that of P4-600 absorbent. However, P4-600 absorbent represented better performance than PKM1-SU absorbent from the view points of regeneration temperature and regeneration rate. For PKM1-SU absorbent, $CO_2$ sorption capacity increased as the steam concentration increased. However, $CO_2$ sorption capacity increased initially as the steam concentration increased from 5% to 10%, but maintained thereafter for P4-600 absorbent. For both $CO_2$ absorbents, $CO_2$ sorption capacity increased as the final regeneration temperature increased. For PKM1-SU absorbent, $CO_2$ sorption capacity increased as the pressure increased and the increment tendency was drastic at higher pressure than 15 bar.

Acceleration of Integra Incorporation in Reconstruction of Burn Scar Contracture with The Vacuum-Assisted Closure(VAC) (Integra®를 이용한 화상 반흔 구축 재건에 있어 Vacuum-Assisted Closure(VAC)의 유용성)

  • Oh, Suk Joon;Jeon, Man Kyung;Ko, Sung Hoon
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.432-436
    • /
    • 2009
  • Purpose: Negative pressure therapy has been used in various conditions to promote wound healing. It has also been used to secure a skin graft by improving microcirculation and improving tight adhesion between the graft and the recipient bed. To reduce post burn scar contracture and improve aesthetical result, many types of dermal substitutes have been invented and used widely. The goal of this study was evaluate usefulness of the VAC (Kinetic concepts Inc., San Antonio, TX) in improving the take rate and time to incorporation of Integra$^{(R)}$ in reconstruction of burn scar contracture. Methods: A retrospective study was performed from October, 2006 to December, 2008. The VAC was utilized for 11 patients. The average patient's age was 19.7 years (range 5 - 27) and average surface area was $785cm^2$ (range 24 - 1600). The burn scars were excised deep into normal subcutaneous tissue to achieve complete release of the scar, Integra$^{(R)}$ was sutured in place with skin staple와 Steri - strip$^{(R)}$. Then slit incisions were made on silicone sheet only with No.11 blade for effective drainage. The VAC was used as a bolster dressing over Integra$^{(R)}$. Negative - Pressure ranging from 100 to 125 mm Hg was applied to black polyurethane foam sponge trimmed to the appropriate wound size. An occlusive seal over the black polyurethane foam sponge was maintained by a combination of the occlusive dressing, OP - site$^{(R)}$. The VAC dressing changes were performed every 3 or 4 days until adequate incorporation was obtained. The neodermis appeared slightly yellow to orange color. When the Integra$^{(R)}$ deemed clinically incorporated, The VAC was removed and take was estimated with visual inspection. Very thin STSG(0.006 ~ 0.008 inches) was performed after silicone sheet removal. Result: The mean time for clinically assessed incorporation of Integra$^{(R)}$ was 10.00 days (range 9 - 12). The mean dressing change was 3.5 times until take was obtained. In All patients, Integra$^{(R)}$ had successful incorporation in tissue without serious complications. Conclusion: Integra$^{(R)}$ in combination with Vacuum - Assisted Closure(VAC) may be incorporated earlier than conventional dressing method.

A Study on the Buckling Stability due to Lateral Impact of Gas Pipe Installed on the Sea-bed (해저면에 설치된 가스관의 외부충격에 의한 좌굴 안전성 검토)

  • Park, Joo-Shin;Yi, Myung-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.414-421
    • /
    • 2022
  • Subsea oil and gas exploration is increasingly moving into deeper water depths, and typically, subsea pipelines operate under high pressure and temperature conditions. Owing to the difference in these components, the axial force in the pipe is accumulated. When a pipeline is operated at a high internal pressure and temperature, it will attempt to expand and contract for differential temperature changes. Typically, the line is not free to move because of the plane strain constraints in the longitudinal direction and soil friction effects. For a positive differential temperature, it will be subjected to an axial compressive load, and when this load reaches a certain critical value, the pipe may experience vertical (upheaval buckling) or lateral (snaking buckling) movements that can jeopardize the structural integrity of the pipeline. In these circumstances, the pipeline behavior should be evaluated to ensure the pipeline structural integrity during operation in those demanding loading conditions. Performing this analysis, the correct mitigation measures for thermal buckling can be considered either by accepting bar buckling but preventing the development of excessive bending moment or by preventing any occurrence of bending.

Effect of Supplementary or Heating Lamps on the Yield, Vase Life, and Leaf Color of Cut Rose (보광등과 난방등이 절화장미 수확량, 절화수명, 엽색에 미치는 영향)

  • Jeong, Kyeong Jin;Yun, Jae Gill;Chon, Young Shin;Shin, Hyun Suk;Lee, Sang Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.2
    • /
    • pp.158-165
    • /
    • 2018
  • The effects of different kinds of supplementary lighting or heating lamps on the yield, cut flower life, and leaf color of cut rose were compared and analyzed. For this purpose, light emitting diode lamp (LED), metal halide lamps (MH), and high-pressure sodium lamps (HPS) as the supplementary lamps, and carbon fiber infrared lamp (NCFI) were installed on hydroponic cultivation bed in a cut rose farm. The yield of cut flower rose and the number of marketable flowers were greatly increased in spring and autumn by HPS treatment, but not in winter. The length of flower stalk was longer than that of control in the spring but decreased in winter. It seemed likely that the shorter flower stalk in winter was due to the shortened period of vegetative growth compared to the control because flowering was promoted by supplementary lighting. Vase life was not different among treatments in the autumn when the lighting time was short, but in winter, it was prolonged to 3 more days by only HPS, compared with the control. Leaf color was significantly affected by light treatment in winter rather than autumn. Leaf color was darkened in all supplementary lamps (LED, MH, HPS) treatment, whereas NCFI was similar to the control in leaf color. In conclusion, HPS is considered to be a very good supplementary lamp because it increases the length of flower stalk and the yield and prolongs vase life in cut roses. Even though NCFI could function as a heating lamp radiating a lot of heat, it was considered that the role as a supplementary light is unsatisfactory because the number of marketable flowers decreases and the quality index of cut rose deteriorates by NCFI.

A Study on Nursing Service of Chronic Diseases by the First Step and Third Step Medical Treatment (1차 및 3차 진료기관 이용 만성질환자의 간호서비스에 관한 연구)

  • Cho Chong Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.103-118
    • /
    • 1996
  • It is to be growing up the interest of community health affairs through visiting nursing care. The health medical treatment of Korea has been changed largely on the period. The juvenile population has decreased. This means that is has took the population consensus of advanced national organization to be increased by the old age. The transition of disease has changed from the contagious disease importance to the chronicity disease omportance because the domestic district population has experienced the sudden urbanization circumstance district population has experienced the sudden urbanization circumstance to be growing up $70\%$ of the whole population. When the nursing service has common function to be delivering from all direction to home, this study is getting the great important phase velocity in order to manage the kernel questional adult chronicity disease of health medical institution at the present age. (1) community over system or with people particularity (2) the first of third step medical treatments. The variety of medical treatments organization has quantity of the delivery manpower and specially between consumers and rdlated person. A qualitative difference is showed at the purpose to be seizing. That research related person is use at district health center in Seoul, by foundation on nurse registration book of H collage hospital and public health registration book. According the chronicity disease. age. and sex. nature agree-able standard 54 people took the content analysis on nurse registration book of total 108 people. The results of the study were as follows: 1. General background factors are houses or kind of medical facilities and number of patients in family. The first medical treatment is more patients than third medical treatment organization. The first medical treatment of economic environment os appering to be worse. 2. The chronicity disease frequency have been different speciality according to medical treatment organization. On case of the first medical treatment. Diabetes and High Blood Pressure were good but Cerebrum Vascular Accident(CVA) showed many for bed case. In addition. the number of family is comparative large exception of CVA on according for moving condition and health more than the first medical treatment. However. family condition. whole family percentage is decreasing preferably through the potential resource is increasing by the number of and the construction of family. The ability of real resource is considered to be low. 3. The average percentage of nurse service has appered to be differed two groups by the first step medical treatment(33.72 times) and third step medical treatment(45.70 times). However, the difference (the first step medical treatment and third step medical treatment) is to be limited to issue the medicine at the service. The condition of nurse care was the indirect nursing care. Supportiong area was to be related to volunteer service and administration support. 4. The various nursing care average percentage of the chronicity disease was increased by orders of Diabetes. High Blood Pressure. and CVA in examination result and the medical treatment. The indirect nursing care was also same. At third step medical treatment, orders of chronicity disease were same. The case of other area on service conditions were increased by order of Diabetes. High Blood Pressure, and CVA. However. it is never appearing the difference at bottleneck affairs nursing care. 5. When the visiting nursing care demand particularly. the average percentage of nursing care from the first step medical treatment that the time under a person is many more than the time over two people. However, there was no difference in statistic. Third step medical treatment is $49.81\%$ at the time under a person. The average nursing care service is appeared by more many when the visiting nursing care demand is a few by 12.83 at the time over two people. 6. By visiting nursing care percentage to be frequency that nursing care averaghe percentage and inter-relation are large. The related factor of the first medical treatment is 0.96. However, the related factor of third medical treatment has shown the decreased 0.49 for the condition of relation more than that. Therefore. the nursing care average percentage is related to the visiting times of a nurse. This result is be showing the obvious fact that the first step medical treatment is few more than third step medical treatment.

  • PDF

Comparison of Awareness of Symptoms and Illness Between Patients with Obstructive Sleep Apnea and Simple Snoring (수면무호흡증과 단순 코골이 환자의 증상과 질환 인식도 비교)

  • Lee, Seyoung;Kang, Jae Myeong;Cho, Yoon-Soo;Yoon, Hyun Jin;Kim, Ji-Eun;Shin, Seung-Heon;Park, Kee Hyung;Kim, Seon Tae;Kang, Seung-Gul
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.1
    • /
    • pp.16-24
    • /
    • 2016
  • Background and Objectives: Obstructive sleep apnea (OSA) is often undiagnosed but is an important risk factor affecting the health of an individual. The level of awareness of the illness among patients with OSA is low and is not correlated with severity of the illness. This study was conducted to compare awareness of OSA symptoms and illness between patients with OSA and simple snorers. Materials and Methods: Two hundred eighty-two patients who were suspected of having OSA participated in this study. All subjects underwent overnight polysomnography. Those with an apnea-hypopnea index (AHI) ${\geq}5$ were classified as the OSA group, while those with an AHI < 5 were classified as the simple snoring group. A sleep questionnaire, which included items on awareness of the illness, OSA, and sleep symptoms, was administered to all subjects and their bed-partners. Results: Simple snorers were much more aware of their symptoms such as snoring, irregular breathing, and apnea than were patients with OSA. Bed-partners of simple snorers were also more aware of the participants' sleep symptoms than were partners of patients with OSA. However, the duration of OSA symptoms was longer in the OSA group. In the correlation analysis, the level of awareness of OSA symptoms was negatively correlated with AHI, age, body mass index, and Epworth Sleepiness Scale score. Among the sleep questionnaire and polysomnography results, only Pittsburgh Sleep Quality Index was positively correlated with level of awareness of OSA symptoms. The minority of the respondents had heard about the treatment methods of continuous positive airway pressure and oral appliance and preferred them as treatment options. Conclusion: This study suggests that simple snorers are more aware of their symptoms than are patients with OSA. A higher severity of OSA, represented by a higher AHI, is correlated with lower awareness of one's OSA symptoms.

Development of the Advanced Manganese-Based Sorbent for Hot Coal Gas Desulfurization (고온 석탄 가스 탈황을 위한 개선된 망간계 탈황제 개발)

  • Shon, Byung-Hyun;Choi, Eun-Hwa;Cho, Ki-Chul;Jeon, Dae-Young;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.291-302
    • /
    • 2000
  • This experiments have been made to develop of manganese-based sorbent for the removal of hydrogen sulfide from hot coal gases. Manganese-based sorbent were tested in an ambient-pressure fixed-bed reactor to determine steady state $H_2S$ concentrations, breakthrough times and feasibility of the sorbent when subjected to cycle sulfidation and regeneration testing. Effects of particle size of sorbent, temperature of sulfidation, regeneration temperature and regeneration characteristics on the $H_2S$ removal efficiency were investigated. Experimental results showed that the $H_2S$ removal efficiency was optimal when the temperature was about $800^{\circ}C$ and the smaller particle size, the better $H_2S$ removal efficiency but in the range of 0.214~0.631mm didn't influence it much. The equilibrium constant(K) is represented as a log(K)=3.396/T-1.1105 and the utilization efficiency of sorbents was about 92% at $800^{\circ}C$. Regeneration in air produced $SO_2$ concentration as high as 8.5% at $800^{\circ}C$, 8.4% at $850^{\circ}C$, and 8.8% at $900^{\circ}C$ and may be used in sulfuric acid production.

  • PDF

A Study on the Removal of Aromatic Compounds from Soil and Zeolite Using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 토양과 제올라이트중의 방향족 화합물 제거에 관한 연구)

  • Bae, Won;Shin, Bohyun;Kang, Hoseok;Kim, Hwayong
    • Clean Technology
    • /
    • v.9 no.4
    • /
    • pp.197-206
    • /
    • 2003
  • We performed removal of aromatic compounds, benzene and toluene, from soil and zeolite using supercritical carbon dioxide. Extraction was performed at $50^{\circ}C$ and 27.7 MPa with changing the extent of pollutant concentration and the results were compared and analyzed. Experiments were carried out using flow method and high pressure extractor of 1.27 cm in diameter and 25cm in length was used. The pollutants were sampled every ten minutes and their concentrations were analyzed with GC/FID. As a result, highly contaminated sample followed solubility/elution model and slightly contaminated sample followed desorption/kinetics model. At the same condition benzene was extracted faster than toluene. In the case of zeolite, more time is required to extract pollutants than soil. This phenomena was due to high adsorption capacity of zeolite. In the case of highly contaminated soil, we could correlate experimental data using simple Brady's fixed bed extractor model. But in the case of slightly contaminated soil, that was governed with desorption/kinetics model, there was some errors.

  • PDF