• Title/Summary/Keyword: Beat frequency

Search Result 171, Processing Time 0.025 seconds

Integrated Transceiver Module development at Ka-Band (Ka-Band의 집적화된 송수신 모듈 개발)

  • Kim, Wan-Sik;Jung, Yun-Man;Kim, Gye-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.5 s.43
    • /
    • pp.267-272
    • /
    • 2006
  • In this paper, an integrated and small Ka-band transceiver module has been developed for measuring distance at the radar systems. Oscillator of cavity type, The MMIC such as VCO, power amplifier, LNA, and mixer, and passive components are integrated on carriers and these are assembled in the transceiver module directly. The test result shows the output power of 21dBm and the noise figure of 5dB using developed transceiver module. Using developed FMCW transceiver module. We can measure the 60m range target by detecting the beat frequency and distinguish both earth and sky using radiometer signal. So we defined that the integrated module using MMIC had a good performance for the radar and radiometer at Ka-band.

  • PDF

Basic Study for Stress Analysis Using an Unconstrained BCG Monitoring System (무구속 심탄도 모니터링 시스템을 이용한 스트레스 분석 기초연구)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.118-123
    • /
    • 2011
  • Heart related diseases mainly caused by heavy work load and increasing stress in human daily life. Therefore, researches on mobile healthcare monitoring for daily life has been carried out. Notably, wearable healthcare monitoring system which has least restriction has been tried to provide an emergency alert of abnormal heart rate. In this study, we developed chair type unconstrained BCG measurement system which able to perform continuous heart status monitoring at the office and daily life in the unconstrained way. Furthermore, adaptive threshold is used to detect the heart rate from BCG signals. The HRV(heart rate variability) is calculated from heart rate interval. ECG signal measured using conventional method and BCG signal measured using unconstraint system are carried out simultaneously for the purpose of performance evaluation. From the comparison result, BCG signal shows a similar heart beat characteristic as ECG signal. This proves the possibility of practical implementation of unconstraint healthcare monitoring system. In addition, medical examination like valsalva maneuver is performed to observe the changes in HRV due to stress. By performing valsalva maneuver, heart is said to be placed under an artificial physical stress condition. Under this artificial physical stress condition, the time and frequency domain of HRV parameters are evaluated.

Analysis of Windowing Effects in the Estimation of Beat Frequencies (비트 주파수 추정에서의 윈도잉 효과 분석)

  • Lee, Jong-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.668-670
    • /
    • 2010
  • It is necessary to estimate the range and Doppler shifted spectrum for the extraction of useful information from the return echoes in the frequency modulated continuous wave radar systems used for the remote sending purpose such as detection of moving targets. However, the spectrum estimation using the FFT method causes the very large sidolobes of clutter masking the essential signal information if the acquisition time of an echo signal is pretty short. Therefore, in this paper, the efficient data windowing method is investigated to suppress the strong sidelobe levels of the clutter and results are analyzed.

  • PDF

The fourth-order interference between entangled state photon pairs with different frequencies (진동수가 서로 다른 얽힘상태 광자쌍의 4차 간섭)

  • Kim, Heon-Oh;Ko, Jeong-Hoon;Kim, Tae-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.308-313
    • /
    • 2002
  • One of the nonclassical effects in two-photon interference experiments, spatial quantum beating, is observed in fourth-order interference with pairs of photons produced by a spontaneous parametric down-conversion process. When photon pairs in different frequencies $\omega1$ and $\omega2$ are mixed together, and directed to two detectors, the coincidence counts exhibit a cosine modulation with difference frequency | $\omega1$- $\omega2$|. The measured coincidence counts turned out to have an interference pattern with periodicity of 10.45 ㎛ in position or 34.82fs in time delay, which corresponds to the period 2$\pi$/| $\omega1$- $\omega2$| for the beat frequency of 0.29${\times}10^{14}$Hz.

Implementation of Signal Processing Algorithms for an FMCW Radar Altimeter (FMCW 전파고도계의 신호처리 알고리즘 구현)

  • Choi, Jae-Hyun;Jang, Jong-Hun;Lee, Jae-Hwan;Roh, Jin-Eep
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.6
    • /
    • pp.555-563
    • /
    • 2015
  • This paper presents signal processing algorithms of a frequency-modulated continuous-wave(FMCW) radar altimeter and provides a practical assessment technique. The radar altimeter is initially operated in search mode, when the radar altimeter detects a valid altitude, search mode is switched to track mode and a altitude being tracked is displayed. The sweep bandwidth in each mode is a function of altitude to narrow the beat frequency bandwidth. In addition, transmit power and receiver gain in each mode are controlled to compensate for the dynamic range of wide altitude range. To assess more realistic operation, the radar altimeter was tested using the crane setup. The crane test demonstrated that signal processing algorithms described in this paper resulted in a reduced measurement error rate.

Effect of in-Plane Magnetic Field on Rashba Spin-Orbit Interaction

  • Choi, Won Young;Kwon, Jae Hyun;Chang, Joonyeon;Han, Suk Hee;Koo, Hyun Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.394-394
    • /
    • 2013
  • The spin-orbit interaction has received great attention in the field of spintronics, because of its property and applicability. For instance, the spin-orbit interaction induces spin precession which is the key element of spin transistor proposed by Datta and Das, since frequency of precession can be controlled by electric field. The spin-orbit interaction is classified according to its origin, Dresselhaus and Rashba spin-orbit interaction. In particular, the Rashba spin-orbit interaction is induced by inversion asymmetry of quantum well structure and the slope of conduction band represents the strength of Rashba spin-orbit interaction. The strength of spin-orbit interaction is experimentally obtained from the Shubnikov de Hass (SdH) oscillation. The SdH oscillation is resistance change of channel for perpendicular magnetic field as a result of Zeeman spin splitting of Landau level, quantization of cyclotron motion by applied magnetic field. The frequency of oscillation is different for spin up and down due to the Rashba spin-orbit interaction. Consequently, the SdH oscillation shows the beat patterns. In many research studies, the spin-orbit interaction was treated as a tool for electrical manipulation of spin. On the other hands, it can be considered that the Rashba field, effective magnetic field induced by Rashba effect, may interact with external magnetic field. In order to investigate this issue, we utilized InAs quantum well layer, sandwiched by InGaAs/InAlAs as cladding layer. Then, the SdH oscillation was observed with tilted magnetic field in y-z plane. The y-component (longitudinal term) of applied magnetic field will interact with the Rashba field and the z-component (perpendicular term) will induce the Zeeman effect. As a result, the strength of spin-orbit interaction was increased (decreased), when applied magnetic field is parallel (anti-parallel) to the Rashba field. We found a possibility to control the spin precession with magnetic field.

  • PDF

An analysis of correlation between EEG signal and HRV during attentional status with children under 15 years (15세 미만 아동을 대상으로 한 집중상태에서 EEG 신호와 HRV의 상관관계 분석)

  • Choi, Woo-Jin;Lee, Chug-Ki;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.269-278
    • /
    • 2011
  • This paper illustrates the inter-relationship between the theta/alpha ratio of the EEG signal and multiple HRV related parameters associated with the cardiovascular system response during event-related stimuli. Both EEG and PPG signals were simultaneously recorded in 21 healthy subjects. All subjects had their attention focused on the CNT program for nine minutes. Time-frequency analysis was applied to the EEG and PPG signals. The theta/alpha ratio was extracted from the EEG results, and the HRV features, including beat interval(1), SDNN(2), RMSSD(3), NN50(4), LF(5), HF(6), and LFIHF(7), were extracted from the PPG. Through multiple linear regression, the relationship ($R^2$) between the multiple combined features and the theta/alpha rhythm was identified. As a result, the combinations of $R^2$($R^2=0.253$; seven dimensions) and the theta/alpha ratio indicated a higher inter-relationship value than those of other combinations. The combinations of features that were greater than three dimensions, based on {SDNN(2), HF(6)}, generally showed higher $R^2$ value. We demonstrate that the high dimensional combinations had a higher correlation than did the low dimensional combinations.

  • PDF

EFFECT OF PATIENT'S BREATHING PATTERN ON THE STRESS CHANGES IN THIRD MOLAR EXTRACTION (제 3 대구치 발치시 환자의 호흡 패턴이 스트레스 변화 양상에 미치는 영향)

  • Rhee, Sang-Myung;Kim, Hyung-Wook;Park, Yang-Ho;Kim, Jin-Cheol;Park, Jun-Woo;Rhee, Sung-Jun;Nyamdorj, Selenge;Ahn, Jae-Mok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.485-493
    • /
    • 2007
  • Purpose: Heart rate variability(HRV) is the clinical consequence of various influences of the autonomic nervous system(ANS) on heart beat. HRV can estimate the potential physiologic rhythm from the interval between consecutive beats(RR interval or HRV data). It is known as RSA which represents respiration-related HR rhythmic oscillation. Previous studies demonstrated a specific breathing pattern(0.1Hz, 6breaths/min) to improve a physiological body condition related to the stress. In this paper, the level of stress would be evaluated in terms of three phases of the dental treatment, combined with 6breaths/min. Methods: These phases include before, during and after tooth extraction or anesthesia or something.36 patients' stresses were assessed using HRV stress analyzer in each phase in Kangdong Sacred Heart Hospital, and Chuncheon Sacred Heart Hospital, Hallym University Medical Center from Jun. to Sept. of 2007. HRV 5-min data collected were analyzed in time-domain and frequency-domain to evaluate the activity of autonomic nervous system(ANS) which represents the level of stress. Results: All HRV parameters including HF(high frequency), LF(low frequency) and LF/HF ratio showned a significant change affecting the ANS balance. There was a 6.4% difference between R(LF/HF)s on general breathing pattern for balance of Autonomic nervous system, but on controlled breathing pattern, 0.1Hz, was made narrow till 1.4%. The activity of ANS has increased by 1.4% on general breathing pattern, and by 2.9% on controlled breathing pattern, 0.1Hz. Conclusion: After analysis of preoperative stress changes and effect of breathing pattern of 0.1 Hz on the stress in 36 patients who have undergone third molar extraction, following was concluded. In the preoperative stage, the sympathetic change was the greatest?after the?anesthetic injection, and stress was relieved by controlling the breathing pattern to a frequency of 0.1Hz.

Ameliorating Effect of Selenium against Arsenic Induced Male Reproductive Toxicity in Rats

  • Jalaludeen, Abdulkadhar Mohamed;Lee, Ran;Lee, Won Young;Kim, Dong Hoon;Song, Hyuk
    • Reproductive and Developmental Biology
    • /
    • v.38 no.3
    • /
    • pp.107-114
    • /
    • 2014
  • Oral exposure of humans by excess amounts of arsenic may cause disturbances of the reproductive system. In the present study, such exposure was modelled in rats, with the support of sperm principal parameters and histopathological observations. Male Sprague-Dawley rats were randomly divided into three groups where the group I was served as a normal control, group II was received sodium meta-arsenite as arsenic (10 mg/kg b.w/day) and a combination of sodium meta-arsenite and sodium selenite (3 mg/kg b.w/day) in group III. After 6 weeks, there was no significant change in testis weight and in total motility of all the three experimental groups, whereas, rapid moving spermatozoa, moderately moving spermatozoa and slow moving spermatozoa were significantly decreased in arsenic treated rats as compared to control rats. The other sperm principal parameters like progressiveness, average path velocity, straightness linear velocity (VSL), curvilinear velocity (VCL), straightness, linearity sperm head elongation ratio, area, linearity amplitude of lateral head department (ALH) and beat cross frequency (BCF) were found to be reduced in arsenic intoxicated rats. These results are not correlated with the histological studies. On oral administration of selenium ameliorated the adverse effects of arsenic as compared to arsenic alone treated rats. Our findings clearly demonstrate that administration of selenium could prevent some of the deleterious effects of arsenic in the testis.

Double Demodulation of a Ring Laser Dither Signal for Reducing the Dynamic Error of an Inertial Navigation System (관성항법장치의 동적오차 개선을 위한 링레이저 각진동 신호의 이중 복조방법)

  • Shim, Kyu-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.82-89
    • /
    • 2014
  • This paper discusses the methods for reducing the sampling time quantization errors of the body dither type ring laser gyroscope. A ring laser gyroscope has the angle quantization error which is generated by the frequency counting method of the laser beat signal and sampling time quantization error which is generated by the demodulation method for eliminating the body dithering in which the sampling periods are fitted to the dither periods. Generally, because the dither periods are longer than the calculation periods of the inertial navigation system, vehicle navigation errors are produced by long time attitude update missing during the vehicle move with a high dynamical motion. In this paper, the double demodulation method is proposed for reducing the sampling time quantization error and its effects under the dynamic situation are confirmed by simulation.