• 제목/요약/키워드: Beam-to-Column Connections

검색결과 484건 처리시간 0.025초

Strain penetration of high-strength steel bars anchored in reinforced concrete beam-column connections

  • Li, Ling;Zheng, Wenzhong;Wang, Ying
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.367-382
    • /
    • 2019
  • This paper presents experimental and analytical investigations on additional fixed-end rotations resulting from the strain penetration of high-strength reinforcement in reinforced concrete (RC) beam-column connections under monotonic loading. The experimental part included the test of 18 interior beam-column connections with straight long steel bars and 24 exterior beam-column connections with hooked and headed steel bars. Rebar strains along the anchorage length were recorded at the yielding and ultimate states. Furthermore, a numerical program was developed to study the effect of strain penetration in beam-column connections. The numerical results showed good agreement with the test results. Finally, 87 simulated specimens were designed with various parameters based on the test specimens. The effect of concrete compressive strength ($f_c$), yield strength ($f_y$), diameter ($d_b$), and anchorage length ($l_{ah}$) of the reinforcement in the beam-column connection was examined through a parametric study. The results indicated that additional fixed-end rotations increased with a decrease in $f_c$ and an increase in $f_y$, $d_b$ and $l_{ah}$. Moreover, the growth rate of additional fixed-end rotations at the yielding state was faster than that at the ultimate state when high-strength steel bars were used.

복합모멘트접합을 갖는 콘크리트 충전 보-기둥 합성접합부의 반복하중 실험 (Cyclic Loading Tests of Concrete-Filled Composite Beam-Column Connections with Hybrid Moment Connections)

  • 임종진;김동관;이상현;이창남;엄태성
    • 한국강구조학회 논문집
    • /
    • 제28권5호
    • /
    • pp.345-354
    • /
    • 2016
  • 최근 합성 보-기둥 접합부를 위한 복합모멘트접합(hybrid moment connection)상세가 개발되었다. 기둥으로 팔각형태의 콘크리트 충전강관이 사용되었고, 보에는 U단면 콘크리트 충전강관이 사용되었다. 보-기둥 모멘트접합을 위해 보 강관은 기둥 강판에 직접 용접되었다. 하지만 보 하부 플랜지는 응력집중을 피하기 위하여 기둥 강판에 용접되지 않았고, 대신 보 플랜지의 인장력을 전달하기 위해 기둥 관통철근이 사용되었다. 기존 외다이어프램 보강상세 및 복합모멘트접합 상세를 갖는 총 4개의 실험체를 제작하고, 반복하중실험을 수행하였다. 실험결과 복합모멘트접합 상세는 보 플랜지의 인장력이 기둥 내부로 효과적으로 전달되었다. 또한, 하중재하능력 및 변형능력이 기존 외다이어프램 상세와 거의 동일한 수준으로 나타났다. 하지만, 최종 접합부 파괴모드는 복합모멘트접합 상세에 따라 영향을 받았다.

철근콘크리트 보-기둥 접합부의 비탄성 회전 능력에 대한 성능 평가 (Performance Evaluation of Inelastic Rotation Capacity of Reinforced Concrete Beam-Column Connections)

  • 이기학;우성우
    • 한국지진공학회논문집
    • /
    • 제11권5호
    • /
    • pp.1-9
    • /
    • 2007
  • 본 논문에서는 철근콘크리트 모멘트 골조의 보-기둥 접합부에 대한 비탄성 회전 능력의 성능을 조사한 연구 결과를 하고 있다. 총 91개의 보-기둥 접합부 실험체에 대해 상세히 조사되었으며, 그 중 28개의 실험체는 ACI 318-02의 상세 요구에 기초하여 특수 모멘트 골조 접합부로서 분류되었다. AISC-97 내진 기준에서 철골 모멘트 골조 접합부를 위해 정의된 허용기준이 분류된 철근콘크리트 모멘트 골조의 접합부에 대해 평가하기 위해서 사용되었다. 특수 모멘트 골조 접합부에 대한 설계 상세를 만족하는 28개의 실험체 중 27개의 특수 모멘트 골조 접합부가 충분한 강도를 가지고 있었으며, 급격한 강도 감소 없이 0.03 rad.의 소성 회전에 대해 연성 거동을 발휘할 수 있음을 보여 주었다. 접합부의 전단 강도, 기둥과 보에 대한 휨 강도 비율, 접합부내에서의 횡방향 철근비 등에 대한 제한이 보-기둥 접합부의 만족스런 내진 성능을 보여주는데 중요한 역할을 하였다.

컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안 (Modeling Parameters for Column-Tree Type Steel Beam-Column Connections)

  • 안희태;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2023
  • The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

Experimental study on two types of new beam-to-column connections

  • Ma, Hongwei;Jiang, Weishan;Cho, Chongdu
    • Steel and Composite Structures
    • /
    • 제11권4호
    • /
    • pp.291-305
    • /
    • 2011
  • The new structure consisting of continuous compound spiral hoop reinforced concrete (CCSHRC)column and steel concrete composite (SCC) beam has both the advantages of steel structures and concrete structures. Two types of beam-to-column connections applied in this structural system are presented in this paper. The connection details are as follows: the main bars in beam concrete pass through the core zone for both types of connections. For connecting bar connection, the steel I-beam webs are connected by bolts to a steel plate passing through the joint while the top and bottom flanges of the beams are connected by four straight and two X-shaped bars. For bolted end-plate connection, the steel I-beam webs are connected by stiffened extended end-plates and eight long shank bolts passing through the core zone. In order to study the seismic behaviour and failure mechanisms of the connections, quasi-static tests were conducted on both types of full-scale connection subassemblies and core zone specimens. The load-drift hysteresis loops show a plateau for the connecting bar connection while they are excellent plump for bolted end-plate connection. The shear capacity formulas of both types of connections are presented and the values calculated by the formula agree well with the test results.

Seismic behavior of beam-to-column connections with elliptic slit dampers

  • Shahri, Saeed Farahi;Mousavi, Seyed Roohollah
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.289-301
    • /
    • 2018
  • The rigid steel connections were suffered severe damage because of low rotational capacity during earthquakes. Hence, many investigations have been conducted on the connections of steel structures. As a solution, steel slit dampers were employed at the connections to prevent brittle failure of connections and damage of main structural members. Slit damper is a plate or a standard section with a number of slits in the web. The objective of this paper is to improve the seismic performance of steel slit dampers in the beam-to-column connection using finite element modeling. With reviewing the previous investigations, it is observed that slit dampers were commonly fractured in the end parts of the struts. This may be due to the low participation of struts middle parts in the energy dissipation. Thus, in the present study slit damper with elliptic slits is proposed in such a way that end parts of struts have more energy absorption area than struts middle parts. A parametric study is conducted to investigate the effects of geometric parameters of elliptic slit damper such as strut width, strut height and plate thickness on the seismic performance of the beam-to-column connection. The stress distribution is improved along the struts in the proposed slit damper with elliptic slits and the stress concentration is decreased in the end parts of struts. The average contributions of elliptic slit dampers, beam and other sections to the energy dissipation are about 97.19%, 2.12% and 0.69%, respectively.

종리브로 보강한 콘크리트충전원형강관기둥-H형강보 접합부의 구조적 거동에 관한 연구 (The Structural Behavior of CFCT Column to H-Beam Connections With Longitudinal Rib of Column at Joint)

  • 강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제10권2호통권35호
    • /
    • pp.291-301
    • /
    • 1998
  • 종리브로 보강된 충전형 원형강관에 H형강보를 사용한 접합부 모델실험 결과와 항복선이론 및 수치해석을 이용하여 접합부 국부내력의 추정을 위한 기초 자료를 제시하고 궁극적으로는 원형강관 접합부의 보강법을 연구하여 다이아프램이 없는 콘크리트 충전강관 기둥-H형강보 접합부의 개발을 위한 기초자료를 제시하고자 한다.

  • PDF

Central angle effect on connection behavior of steel box beam-to-circular column

  • Hwang, Won-Sup;Kim, Young-Pil;Yoon, Tae-Yang
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.531-547
    • /
    • 2009
  • This paper presents the experimental results on the strength behavior and failure modes of box beam-to-circular column connections in steel piers. Previous research introduced parameters such as joint central angles, extension of horizontal stiffeners, and use of equivalent web depth, which ignored strength behavior and failure modes of box beam-to-circular column connections. The use of equivalent web depth $d_2$ is not reasonable when central angle ${\alpha}$ is closer to $90^{\circ}$; therefore, a monotonic loading test has been performed for eight connection specimens. From the test, it is identified that the connection with the circular column is stronger than the connection with the box-sectioned substitution column. Also, the strength of the beam-to-column connections with horizontal stiffeners is higher than the one of the no column stiffeners. The concrete-filled effect of box beam-to-circular column connection is also investigated, and the experimental yield strength of the connection is compared with the theoretical one. Also, more a reasonable equivalent web depth is suggested. The failure modes of connection are clearly defined.

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.