DOI QR코드

DOI QR Code

Modeling Parameters for Column-Tree Type Steel Beam-Column Connections

컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안

  • An, Heetae (Department of Architecture Engineering, Hanyang University) ;
  • Kim, Taewan (Department of Architecture Engineering, Kangwon National University) ;
  • Yu, Eunjong (Department of Architecture Engineering, Hanyang University)
  • 안희태 (한양대학교 건축공학과) ;
  • 김태완 (강원대학교 건축공학과) ;
  • 유은종 (한양대학교 건축공학과)
  • Received : 2022.11.09
  • Accepted : 2022.11.17
  • Published : 2023.01.01

Abstract

The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

Keywords

Acknowledgement

본 논문은 국토교통부/국토교통과학기술진흥원의 지원으로 수행되었음(과제번호RS-2021-KA163162).

References

  1. ASCE/SEI, Seismic evaluation and retrofit of existing buildings (41-17). c2017.
  2. NIST, Guidelines for nonlinear structural analysis for design of buildings, part IIa steel moment frames, NIST GCR 17-917-46v2, prepared by the Applied Technology Council for the National Institute of Technology and Standards, Gaithersburg, MD. c2017.
  3. Lee CH, Park JW. Cyclic seismic testing of full-scale column-tree type steel moment connections. Journal of Korean Society of Steel Construction. 1998;10(4):629-639.
  4. Oh KY, So JH, Ha HJ, Lee KM. Seismic performance evaluation of Korean column-tree steel moment connections. International Journal of Steel Structures. 2016 Dec;16(4):1287-1298. https://doi.org/10.1007/s13296-016-0089-5
  5. Lee KK, Chae BS, Kim S. Rotation Capacity Evaluation of Column-Tree Type Steel Moment Connection with Bolt-Slip. Journal of the Korean Society of Hazard Mitigation. 2015 Feb;15(1):39-45. https://doi.org/10.9798/KOSHAM.2015.15.1.39
  6. KDS. Design criteria for steel structures in buildings (41-31-00). c2019. Available from: http://www.kcsc.re.kr
  7. Kim TW, Yu EJ. Seismic analysis of steel moment frames with column-tree connections. Journal of Constructional Steel Research. 2020 May;168:105871.
  8. ANSI/AISC 360, Specification for structural Steel Buildings, American Institute of Steel Construction, Chicago, IL. c2016.
  9. Krawinkler H. Shear in beam-column joints in seismic design of steel frames. Engineering Journal. 1978;15(3).
  10. H. Krawinkler, V.V. Bertero, E.P. Popov, Inelastic Behavior of Steel Beam-to-Column Subassemblages, Report No. EERC-71/7, Earthquake Engineering Research Center, University of California, Berkeley, CA. c1971.
  11. V.V. Bertero, H. Krawinkler, E.P. Popov, Further Studies on Seismic Behavior of Steel Beam-Column Sub-Assemblages, Report No. EERC-73/27, Earthquake Engineering Research Center, University of California, Berkeley, CA. c1973.
  12. OpenSees. open system for earthquake engineering simulation. Available from: http://opensees.berkeley.edu.