• Title/Summary/Keyword: Beam width

Search Result 1,144, Processing Time 0.025 seconds

Array Antenna Design for Ku-Band Terminal of L.E.O Satellite Communication

  • Kang, Seo;Kang, JeongJin;Rothwell, Edward J.
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.41-46
    • /
    • 2022
  • This study is a Ku-band array antenna for the manufacture of low-orbit satellite communication terminals, designed to have miniaturization, high gain, and wide beam width. The transmission of low-orbit satellite communication has a right-rotating circularly polarized wave, and the reception has a left-rotating circularly polarized wave. The 4×8 array antenna was separated for transmission and reception, and it was combined with the RF circuit part of the transmitter and receiver, and was terminated in the form of a waveguide for RF signal impedance matching in the form of a transition from the microstrip line to the waveguide. The 30° beam width of the receiver maximum gain of 19 dBi and the 29° beam width of the transmitter maximum gain of 18 dBi are shown. Through this antenna configuration, the system was configured to suit the low-orbit satellite transmission/reception characteristics.

Practical theory and ocean survey application of side scan sonar (Side Scan Sonar 실무이론과 현장조사에 적용)

  • Kim, Seong-Ryul;Lee, Yong-Kuk;Jung, Baek-Hun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.201-204
    • /
    • 2006
  • In the side scan sonar method, use is made of the back-scattering, at low grazing angles of incidence to the seabed, of relatively high-frequency acoustic waves radiated in a fan-shaped beam from a transducer contained in a towed body. The fan beam is oriented so that the wider angle is in the vertical plane (scan range) and the narrower angle in the horizontal plane (beam width) with the axis of the beam normal to the ship track. The display of the returns is usually realized as a series of closely spaced intensity-modulated lines on a paper recorder or computer screen display. In this way a two-dimensional picture of the seabed is build up.

  • PDF

Three Dimensional Finite Element Analysis of Structures under Wind Loads (풍하중을 받는 구조물의 3차원 유한요소해석)

  • 김병완;김운학;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.26-33
    • /
    • 2001
  • This paper compares conventional beam analyses with exact three dimensional plate analyses through numerical examples with plates under wind loads in order to study the disadvantages of conventional simplified beam analyses of wind-loaded structures, Bending moments and principal stresses from beam analyses are good agreements with those from plate analyses but torsional moments are not. And it is possible to get result forces which are variant along width directions from plate analyses but not from beam analyses due to constant distributions of result forces along width directions. Therefore exact three dimensional plate analyses are required in the analyses of wind-loaded structures instead of conventional simplified beam analyses.

  • PDF

Detecting width-wise partial delamination in the composite beam using generalized fractal dimension

  • Kumar, S. Keshava;Ganguli, Ranjan;Harursampath, Dineshkumar
    • Smart Structures and Systems
    • /
    • v.19 no.1
    • /
    • pp.91-103
    • /
    • 2017
  • Generalized fractal dimension is used to detect the presence of partial delamination in a composite laminated beam. The effect of boundary conditions and location of delamination on the fractal dimension curve is studied. Appropriability of higher mode shape data for detection of delamination in the beam is evaluated. It is shown that fractal dimension measure can be used to detect the presence of partial delamination in composite beams. It is found that the torsional mode shape is well suited for delamination detection in beams. First natural frequency of delaminated beam is found to be higher than the healthy beam for certain small and partial width delaminations and some boundary conditions. An explanation towards this counter intuitive phenomenon is provided.

Width-to-length ratio comparison between ameloblastomas and odontogenic keratocysts in the body of the mandible: A preliminary study

  • Omami, Galal;Adel, Mohamed
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.319-322
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the utility of the width-to-length ratio for the differentiation of ameloblastomas and odontogenic keratocysts in the body of the mandible. Materials and Methods: This study retrospectively reviewed 9 patients with ameloblastomas and 9 patients with odontogenic keratocysts using cone-beam computed tomography. The width-to-length ratio was determined by measuring the ratio between the greatest buccolingual dimension and the greatest perpendicular anteroposterior dimension of the lesion on the axial view. One-way analysis of variance was used to examine the difference in the width-to-length ratio between the 2 types of lesions. Statistical significance was tested at P<0.05. Results: Ameloblastomas showed a mean width-to-length ratio of 0.64, whereas odontogenic keratocysts showed a mean width-to-length ratio of 0.41. The cut-off value with which the 2 types of lesions were differentiated was 0.5. The width-to-length ratios of ameloblastomas were significantly higher than those of odontogenic keratocysts (P<0.05). Conclusion: The width-to-length ratio might be used to differentiate between ameloblastomas and odontogenic keratocysts.

Effective Beam Width for Flat-Plate Systems Having Edge Beams under Lateral Loads (수평하중을 받는 테두리보가 있는 플랫플레이트 시스템의 유효보폭계수)

  • Han, Sang-Whan;Cho, Ja-Ock;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.213-219
    • /
    • 2008
  • The purpose of this study is to propose frame analysis method for flat plate slabs having edge beam under lateral loads. Flat plate system is defined as the system only with slab of uniform thickness and column. However, the slab system generally incorporate edge beams at exterior connection in actual design. ACI 318 (2005) allows three methods for conducting flat plate system analysis subjected to lateral loads. There are the finite element method (FEM), the equivalent frame method (EFM), and the effective beam width method (EBWM). Among methods, the EBWM enables us to analyze practically by substituting the actual slab to beam element. In this model, the beam element has a thickness equal to that of the slab, and effective beam width equal to some fraction of the slab transverse width. However, the established EBWM was generally proposed for variables of geometry or stiffness reduction factor and seldom proposed for the effect of edge beams. This study verifies that, in the case of flat plate system having edge beams at exterior connections, the lateral stiffness is considerably larger than without edge beams. Therefore it need to analysis method for considered the effect of edge beams. In this study, an analysis model is proposed for the flat plate system having edge beams under lateral loads by considering the effect of edge beams. To verify the accuracy of proposed model, this study compared results of the proposed EBWM with results of FEM of flat plate systems having edge beams under lateral loads. Also, the proposed approach is compared with experimental results of former research.

Laminar Natural Convection Heat Transfer from an Isothermal Rectangular Beam Attached to Horizontal and Vertical Adiabatic Plates (수직 및 수평 단열판에 부착된 등온 사각비임에서의 자연대류 열전달)

  • 박재림;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.95-103
    • /
    • 1992
  • Laminar natural convection heat transfer from an isothermal rectangular beam attached to horizontal and vertical adiabatic plates has been studied for various aspect ratios of the beam and Grashof numbers. The local Nusselt number was increased with decreasing H/B for the constant beam width, B, and with increasing H/B for the constant beam height, H. The total mean Nusselt number of the vertical type was higher than that of horizontal type in the range of H/B.leq.0.52, but reversed in the H/B>0.52 at constant beam width. The total mean Nusselt number of the horizontal type was generally higher than that of vertical type at constant beam height. The total mean Nusselt number of the vertical type was higher than that of horizontal type in the range of H/B.leq.0.43 at constant wetted perimeter, but reversed in the H/B$\leq$0.43.

Continuous variation characteristics of pulse width in short cavity dye laser (단공진기 색소레이저의 펄스폭 연속가변 특성)

  • 김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.512-517
    • /
    • 1999
  • Quenched dye laser (QDL), which operates with relaxation oscillation mode, is one of the most powerful source for ultra-short pulse light. In this paper, the output characteristics of QDL is theoretically analyzed by a computer simulation. The QDL is assumed that the laser dye is Rhodamine 6G which has the oscillation wavelength of 590 nrn and that the active length is 5 mm and that the pumping source is XeCllaser which has oscillation wavelength of 308 nm. It is revealed ilim the pulse width of short cavity dye laser reduced less than 1/100 than pumping pulse duration and has the linear relationship with spatial width of pumping beam approximately. In addition, it is revealed that the short cavity dye laser is a powerful candidate of pulse width variable light source, which is adjusted by spatial size of pumping beam_ beam_

  • PDF

Direct Synthesis of Width-tailored Graphene Nanoribbon on Insulating Substrate

  • Song, U-Seok;Kim, Su-Yeon;Kim, Yu-Seok;Kim, Seong-Hwan;Lee, Su-Il;Jeon, Cheol-Ho;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.564-564
    • /
    • 2012
  • Graphene has been emerged as a fascinating material for future nanoelectronic applications due to its extraordinally electronic properties. However, their zero-bandgap semimetallic nature is a major problem for applications in high performance field-effect transistors (FETs). Graphene nanoribbons (GNRs) with narrow widths (${\geq}10nm$) exhibit semiconducting behavior, which can be used to overcome this problem. In previous reports, GNRs were produced by several approaches, such as electron beam lithography patterning, chemically derived GNRs, longitudinal unzipping of carbon nanotubes, and inorganic nanowire template. Using these methods, however, the width distribution of GNRs was a quiet broad and substantial defects were inevitably occurred. Here, we report a novel approach for fabricating width-tailored GNRs by focused ion beam-assisted chemical vapor deposition (FIB-CVD). Width-tailored phenanthrene ($C_{14}H_{10}$) templates for direct growth of GNRs were prepared on $SiO_2$/Si substrate by FIB-CVD. The GNRs on the templates were synthesized at $900-1,050^{\circ}C$ with introducing $CH_4$ $(20sccm)/H_2$ (10 sccm) mixture gas for 10-300 min. Structural characterizations of the GNRs were carried out using Raman spectroscopy, scanning electron microscopy, and atomic force microscopy.

  • PDF

The Physical Penumbra of the 6MV X-ray (6MV 방사선의 물리학적 Penumbra)

  • Cho Moon-June;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.333-336
    • /
    • 1991
  • High energy Photon beam has a sharp beam margin due to a less side scatter and the other things. But there still remains a penumbra where the dose changes rapidly in the region near the edge of a radiation beam, although it is short in width. It is suggested that the width of the penumbra depends on the source size, distance from source to diaphragm, source to skin distance, and depth in tissue. However, it is also supposed that the other factors influence the penumbra width. In this paper, we investigate changes of the physical penumbra widths according to various field sizes and depths, by using the three dimensional dosimetry system. As a result, we found that as field size and depth increase, the physical penumbra width also increases.

  • PDF