Micromachining Using Laser Beam Machining and Electrochemical Etching (레이저 빔 가공과 전해 에칭을 이용한 미세 가공)

  • Kim, Jang-Woo;Kwon, Min-Ho;Chung, Do-Kwan;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1089-1095
    • /
    • 2012
  • Laser beam machining (LBM) using nanosecond pulsed laser is widely known to be rapid and non-wear process for micromachining. However, the quality itself cannot meet the precision standard due to the recast layer and heat affected zone. In this paper, a fabrication method for machining micro features in stainless steel using a hybrid process of LBM using nanosecond pulsed laser and electrochemical etching (ECE) is reported. ECE uses non-contacting method for precise surface machining and selectively removes the recast layer and heat affected zone produced by laser beam in an effective way. Compared to the single LBM process, the hybrid process of LBM and ECE enhanced the quality of the micro features.

Characterization of a Neutron Beam Following Reconfiguration of the Neutron Radiography Reactor (NRAD) Core and Addition of New Fuel Elements

  • Craft, Aaron E.;Hilton, Bruce A.;Papaioannou, Glen C.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.200-210
    • /
    • 2016
  • The neutron radiography reactor (NRAD) is a 250 kW Mark-II Training, Research, Isotopes, General Atomics (TRIGA) reactor at Idaho National Laboratory, Idaho Falls, ID, USA. The East Radiography Station (ERS) is one of two neutron beams at the NRAD used for neutron radiography, which sits beneath a large hot cell and is primarily used for neutron radiography of highly radioactive objects. Additional fuel elements were added to the NRAD core in 2013 to increase the excess reactivity of the reactor, and may have changed some characteristics of the neutron beamline. This report discusses characterization of the neutron beamline following the addition of fuel to the NRAD. This work includes determination of the facility category according to the American Society for Testing and Materials (ASTM) standards, and also uses an array of gold foils to determine the neutron beam flux and evaluate the neutron beam profile. The NRAD ERS neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. Gold foil activation experiments show that the average neutron flux with length-to-diameter ratio (L/D) = 125 is $5.96{\times}10^6n/cm^2/s$ with a $2{\sigma}$ standard error of $2.90{\times}10^5n/cm^2/s$. The neutron beam profile can be considered flat for qualitative neutron radiographic evaluation purposes. However, the neutron beam profile should be taken into account for quantitative evaluation.

Evaluating Laser Beam Parameters for Ground-to-space Propagation through Atmospheric Turbulence at the Geochang SLR Observatory

  • Ji Hyun Pak;Ji Yong Joo;Jun Ho Lee;Ji In Kim;Soo Hyung Cho;Ki Soo Park;Eui Seung Son
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.382-390
    • /
    • 2024
  • Laser propagation through atmospheric disturbances is vital for applications such as laser optical communication, satellite laser ranging (SLR), laser guide stars (LGS) for adaptive optics (AO), and laser energy transmission systems. Beam degradation, including energy loss and pointing errors caused by atmospheric turbulence, requires thorough numerical analysis. This paper investigates the impact of laser beam parameters on ground-to-space laser propagation up to an altitude of 100 km using vertical atmospheric disturbance profiles from the Geochang SLR Observatory in South Korea. The analysis is confined to 100 km since sodium LGS forms at this altitude, and beyond this point, beam propagation can be considered free space due to the absence of optical disturbances. Focusing on a 100-watt class laser, this study examines parameters such as laser wavelengths, beam size (diameter), beam jitter, and beam quality (M2). Findings reveal that jitter, with an influence exceeding 70%, is the most critical parameter for long-exposure radius and pointing error. Conversely, M2, with an influence over 45%, is most significant for short-exposure radius and scintillation.

Microbiological, Physicochemical, and Sensory Characteristics of Myungran Jeotgal Treated by Electron Beam Irradiation (전자선 조사 명란젓갈의 미생물학적, 이화학적 및 관능적 품질특성)

  • Jung, Samooel;Choe, Jun-Ho;Kim, Bin-Na;Yun, Hye-Jeong;Kim, Yun-Ji;Jo, Cheorun
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.198-203
    • /
    • 2009
  • We examined the effects of electron-beam irradiation(0.5, 1, 2, or 5 kGy) on microbiological, physicochemical, and sensory quality characteristics of Myungran Jeotgal, Korean fermented seafood, during subsequent storage at $4^{\circ}C$ for 2 weeks. Viable counts of total aerobic bacteria, yeasts and molds, and total coliforms fell, after irradiation, to below detection limits($10^1CFU/g$). The pH of irradiated Myungran Jeotgal was maintained during storage but that of the non-irradiated control decreased. Sensory quality was not affected by electron-beam irradiation, except that color scores in samples irradiated with 2 and 5 kGy were lower than that of the control. Lipid oxidation tended to rise with increased irradiation dose and longer storage periods. The results suggest that electron-beam irradiation can be used to extend the shelf-life of Myungran Jeotgal without apparent quality attribute deterioration. However, means of preventing lipid oxidation resulting from electron-beam irradiation need consideration if irradiation is to find further applications in the food industry.

Image Based Quality Assurance of Range Compensator for Proton Beam Therapy (양성자치료용 보상체의 영상기반 정도 관리 기반 프로그램 개발)

  • Kim, Jin-Sung;Yoon, Myong-Geun;Kim, Dong-Wook;Lim, Young-Kyung;Kwak, Jung-Won;Park, So-Ah;Shin, Dong-Ho;Shin, Jung-Wook;Lee, Se-Byeong;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • The main benefit of proton therapy over photon beam radiotherapy is the absence of exit dose, which offers the opportunity for highly conformal dose distributions to target volume while simultaneously irradiating less normal tissue. For proton beam therapy two patient specific beam modifying devices are used. The aperture is used to shape the transverse extension of the proton beam to the shape of the tumor target and a patient-specific compensator attached to the block aperture when required and used to modify the beam range as required by the treatment plan for the patient. A block of range shifting material, shaped on one face in such a way that the distal end of the proton field in the patient takes the shape of the distal end of the target volume. The mechanical quality assurance of range compensator is an essential procedure to confirm the 3 dimensional patient-specific dose distributions. We proposed a new quality assurance method for range compensator based on image processing using X-ray tube of proton therapy treatment room. The depth information, boundaries of each depth of plan compensatorfile and x-ray image of compensator were analyzed and presented over 80% matching results with proposed QA program.

  • PDF

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.

Effect of Electron Beam Irradiation on Microbial Growth and Qualities in Astragalus membranaceus

  • Jin, You-Young;Shin, Hee-Young;Ku, Kyoing-Ju;Song, Kyung-Bin
    • Journal of Applied Biological Chemistry
    • /
    • v.49 no.4
    • /
    • pp.176-179
    • /
    • 2006
  • Electron beam irradiation was applied to examine the microbial growth and qualities of vacuum-packaged Astragalus membranaceus, a Korean medicinal herb. Samples were irradiated at dose of 2, 4, 8, 12, and 16 kGy, respectively. Microbiological data on A. membranaceus showed that populations of total bacteria, yeast and mold, total coliforms were significantly reduced with increase of irradiation dose. Populations of microorganisms in A. membranaceus were decreased by 2-3 log cycles at 8 kGy irradiation. Color measurements showed that electron beam treatment caused negligible changes in Hunter color L, a, and b values of A. membranaceus. Sensory evaluations showed that there were no significant changes among the samples. These results suggest that electron beam irradiated A. membranaceus have better microbial safety and qualities, compared with the non-irradiated control.

Influence of Image Sticking on Electra-Optical Characteristics in Alternating-Current Plasma Display Panels

  • Choi, J.H.;Jung, Y.;Jung, K.B.;Kim, S.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.760-763
    • /
    • 2003
  • We have investigated the electro-optical characteristics of image sticking in AC PDP. Although Image sticking is one of major factors to determine display quality in AC PDP, so far, it has not being reported why it is occurred and how we can prevent it. In this experiment, we have analyzed the effect of MgO protective layer and phosphor on the image sticking and we have measured the difference of firing voltage, brightness and discharge current between sticking image and normal image in AC PDP. As a result, Phosphor degradation is a more major factor than MgO protective layer and the firing voltage of gas discharge in sticking image is higher than that of normal discharge.

  • PDF

Design of compact klystron amplifier using Field-emitter-arrays (FEA)-based cathode

  • Jin, Jeong-Gu;Ha, Hyun-Jun;Park, Gun-Sik
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.59-65
    • /
    • 1999
  • There has been an interest to develop an efficient, compact microwave device using field-emitter-arrays (FEA)-based cathode. Toe valuate the optimum device-efficiency in a compact size, the propagation properties of the premodulated electron beam for the FEA-based cathode is studied in detail by the computer simulation using a PIC code, MAGIC. For the premodulated electron beam whose phase of the energy leads the phase of the current by $\pi$/2, the amplitude of the downstream current modulation can be kept as high as the initial modulation level. Using the beam parameters with the beam voltage of 6kV and the current of 2.0A, 30% of efficiency is predicted when the quality factor of 800 is chosen. the device length is reduced about twice compared with that of the conventional device. The design of practical planar cathode is carried out to meet the minimum diameter of the electron beam as 0.5 mm.

  • PDF

A Circular Bimorph Deformable Mirror for Circular/Annulus/Square Laser Beam Compensation

  • Lee J.H.;Lee Y.C.;Cheon H.J.
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • We are studying the application of an adaptive optics system to upgrade the beam quality of a laser. The adaptive optics (AO) system consists of a bimorph deformable mirror, a Shack-Hartmann sensor and a control system. In most AO applications, the beam aperture is considered to be circular. However, in some cases such as laser beams from unstable resonators, the beam apertures are annulus or a holed-rectangle. In this paper, we investigate how well a bimorph deformable mirror of ${\Phi}120\;mm$ clear aperture can compensate phase distortions for three different beam configurations; 1) ${\Phi}120\;mm$ circular aperture, 2) ${\Phi}100\;mm$ annulus aperture with a ${\Phi}20\;mm$ hole and 3) $70\;mm{\times}70\;mm$ square aperture with a hole of $30\;mm{\times}30\;mm$. This study concludes that the bimorph mirror, which might be considered as a modal controller, can compensate tilt, defocus, coma and astigmatism, and spherical aberration for all three beams.