For the treatment of superficial tumors like squamous cell carcinoma of the head and neck, 6 MV photon beam is not appropriate and a spoiler is widely used to increase dose in the buildup region, while preserving the skin sparing effect. However, commercially available treatment planning systems assume a normal unspoiled beam, thereby cannot predict the buildup dose with spoiler accurately. We aimed to implement a Monte Carlo (MC) based planning system to apply it to the radiation treatment of head and neck. Lucite with thickness of 10-mm was used for the beam spoiler with Siemens Primus 6 MV photon beam. BEAM/DOSXYZ MC system was employed to model the linac and the spoiler. To verify the calculation accuracy of MC simulations, the percent depth doses (PDDs) and profiles with and without spoiler were measured using a parallel-plate chamber. For the MC based planning, we adopted a hybrid interface system between Pinnacle (Philips, USA) and BEAM/DOSXYZ to support treatment parameters of Siemens linac and the spoiler. The measurements of PDDs and profiles agreed with the corresponding MC simulations within 2% (lSD), which demonstrate the reliability of our MC simulations. The spoiler generated electrons make a contribution to the absorbed dose up to depth of 2cm, which shows that the dominant source of increased dose from spoiler system is the contaminating electrons created by the spoiler. The whole procedures necessary for MC based treatment planning were performed seamlessly between Pinnacle and BEAM/DOSXYZ system. This ability helps to increase the clinical efficiency of the spoiler technique. In conclusion, we implemented a MC based treatment planning system for a 6 MV photon beam with a spoiler. We demonstrate sophisticated MC technique makes it possible to predict dose distributions around buildup region accurately.
목 적: 10 MV X-선의 선형가속기를 이용하여 두경부종양 및 임파선 전이 환자를 치료할 시 피부표면 종양에 균일한 선량을 부여하기 위하여 조직 등가물질로 산란판을 제작하였으며 팬톰을 이용한 피부선량을 측정하여 그 효과를 평가하였다. 대상 및 방법: 조직 등가 물질인 lucite로 산란판을 제작하여 가속기의 콜리메이터와 피부사이에 부착하였으며 조사면적의 크기($5{\times}5{\sim}30{\times}30cm^2$)와 산란판 두께 및 피부와 산란판 간의 거리에 따른 피부 및 체표 0.4 cm에서의 선량 변화를 측정하였다. 또한 자체 제작한 산란 판의 체표 선량 증강 효과를 평가하기위해 볼루스를 이용한 체표 선량을 측정하여 그 효과를 비교하였다. 결 과: 10 MV X-선 선형가속기와 피부 사이에 산란판을 설치하여 피부선량이 증가 되었으며 산란판의 위치에 따라 피부선량이 변화되었고, 0.4 cm 깊이의 선량과 최대선량지점이 피부표면쪽으로 이동하였다. 산란판이 일정할 경우 조사면적이 커질수록 표면선량이 증가하고 최대 선량점은 피부표면 방향으로 이동하였다. 또한 산란판의 두께가 두꺼울수록 표면선량이 증가하고 최대 선량점은 피부표면 방향으로 이동하였다. 결 론: 10 MV X-선을 이용하여 두경부 종양 및 임파선 전이 암을 치료할 경우 산란판을 이용하여 이차산란 전자를 피부표면 앞에서 발생시킴으로써 표면근접부의 선량을 증가시켜 종양부위에 균일한 선량을 조사할 수 있었다. 본 연구에서는 조사면적에 따라 적정 산란판 조건을 찾아 임상에서 유용하게 사용하고자 하였으며, 1.2 cm, 1.8 cm 두께의 산란판을 피부로부터 7 cm에 위치 시켰을때 $10{\times}10cm^2$ 조사면적의 표면선량이 각각 60%, 64%로 측정되었고, 0.4 cm 깊이의 선량이 94%, 94%로 가장 이상적으로 관찰되었다.
목 적: 골수 또는 주변 줄기세포 이식을 목적으로 시행하는 전신방사선 조사시, 표면선량의 증가를 위하여 사용되어지는 산란판(beam spoiler)과 환자간의 거리에 따른 표면선량 변화를 측정하여 적정거리를 찾고자 한다. 대상 및 방법: 본 연구를 위해 6 MV X선을 사용하였으며, 조직등가고체팬텀($30{\times}30{\times}30cm^3$)과 평형평판형 전리함 및 전위계를 사용하였다. 선원에서 기준이 되는 팬텀 중심까지의 거리를 400 cm로 위치시키고 조사야 $40{\times}40cm^2$에서 얻은 측정치를 기준값으로 하였다. 또한 평형평판형 전리함을 고체팬텀의 선원 쪽 표면과 선원 반대쪽 표면에 각각 위치시켜 입사지점 선량과 출구지점 선량을 측정하였다. 산란판과 환자와의 적정 거리를 연구하기 위하여 조직 등가 고체 팬텀과 산란판 간의 거리를 $1{\sim}200cm$ 까지 변화시켜 가며 표면 선량을 측정하였다. 이때 조직등가 고체 팬텀은 고정시키고 산란판을 선원방향으로 일정한 간격으로 변화시켜 입사지점 선량과 출구지점 선량을 측정하였으며 이 값을 기측정된 팬텀 중심부 선량으로 나누어 백분율로 분석하였다. 각각의 경우에 대해 MU는 300씩 조사하였다. 결 과: 기준이 되는 체내 중심 선량을 처방 선량으로 간주하였고 산란판의 유무에 관계없이 체내 중심 선량과 출구 선량은 각각 10.7 cGy, 6.7 cGy로 측정되었다. 조직 등가 고체 팬텀과 산란판 사이의 간격이 $50{\sim}60cm$일 때 입사지점 선량 값은 $14.58{\sim}14.92cGy$로 측정되어 기준점 대비 $99.4{\sim}101%$ 범위를 보임에 따라 표면 선량값이 처방선량에 가장 근접한 값으로 측정되었다. 결 론: 본 실험 결과 전신방사선조사시, 조직등가 고체팬텀과 산란판 사이의 간격이 $50{\sim}60cm$일 때 표면선량을 처방선량에 가장 근접하게 조사할 수 있다는 것을 확인 할 수 있었다. 산란판과 환자와의 거리를 $50{\sim}60cm$에 위치시켜 표면선량의 over dose나 under dose의 발생 방지를 위한 주의가 반드시 필요하겠다.
본 연구는 두경부 방사선치료에서 산란판(beam spoiler)과 볼루스(bolus)를 사용함에 따라 깊이가 다른 원발종양과 림프절 전이성 종양의 선량 변화를 이온함과 광자극발광선량계(optically stimulated luminescence detectors. OSLDs)를 이용하여 치료계획검증 방법으로 교차 비교하였다. 치료계획검증은 치료계획시스템에서 얻은 동일 조사 조건을 검출기가 삽입 가능한 고체 팬텀에 모사하는 방법으로 산란판과 0.5, 1 cm 볼루스를 비교하였으며 두 선량계의 교차비교는 측정 오차가 ${\pm}$2% 미만일 때 신뢰성이 있다고 판단하였다. 연구 결과 0.5 cm 두께의 산란판과 피부간 거리가 10 cm 일 때 최적의 선량분포를 얻을 수 있었으며 볼루스에 비하여 피부선량이 작고 중심부 원발종양 선량의 감소가 작았다. 또한 두 선량계의 교차 비교는 ${\pm}$1% 이내로 유의한 결과를 보였다. 두경부 종양의 방사선치료시 산란판을 사용함으로써 피부 부작용을 줄이면서 종양에 최적의 선량분포를 달성할 수 있다고 판단되었으며 향후 임상에 적용하기 위한 연구가 시행되어야 할 것이다.
This study examined the properties of photons and the dose distribution in a human body via a simulation where the total body irradiation(TBI) is performed on a pediatric anthropomorphic phantom and a child size water phantom. Based on this, we tried to find the optimal photon beam energy and material for beam spoiler. In this study, MCNPX (Ver. 2.5.0), a simulation program based on the Monte Carlo method, was used for the photon beam analysis and TBI simulation. Several different beam spoiler materials (plexiglass, copper, lead, aluminium) were used, and three different electron beam energies were used in the simulated accelerator to produce photon beams (6, 10, and 15 MeV). Moreover, both a water phantom for calculating the depth-dependent dosage and a pediatric anthropomorphic phantom for calculating the organ dosage were used. The homogeneity of photon beam was examined in different depths for the water phantom, which shows the 20%-40% difference for each material. Next, the org an doses on pediatric anthropomorphic phantom were examined, and the results showed that the average dose for each part of the body was skin 17.7 Gy, sexual gland 15.2 Gy, digestion 13.8 Gy, liver 11.8 Gy, kidney 9.2 Gy, lungs 6.2 Gy, and brain 4.6 Gy. Moreover, as for the organ doses according to materials, the highest dose was observed in lead while the lowest was observed in plexiglass. Plexiglass in current use is considered the most suitable material, and a 6 or 10 MV photon energy plan tailored to the patient condition is considered more suitable than a higher energy plan.
방사선을 이용한 백혈병의 전신방사선 치료는 환자의 골수에 건강한 골수세포를 이식하는 골수이식(bone marrow transplantation) 시행 전, 골수의 재구성을 위한 준비단계로 전신에 외부 방사선을 조사(external beam therapy)하여 유해한 세포를 죽이거나 면역체계의 억제를 목적으로 시행된다. 전신방사선 치료를 시행할 경우 환자의 표면선량을 증가하기 위해 사용되는 산란판(spoiler)을 사용하게 되는데 산란판을 사용할 때의 표면선량은 환자와의 거리에 따라 달라지고, 두께에 따라 달라지게 된다. 이에 본 논문에서는 산란판의 두께에 따른 표면선량의 변화를 알아보았다. 아크릴로 된 산란판을 0.5 cm부터 3.0 cm 까지 0.5 cm 간격으로 제작하여 각각 측정한 결과 2.0 cm를 기준으로 두께에 따라 약 0.5% 정도의 표면선량의 증가를 관찰 할 수 있었다. 이를 토대로 임상에 직접 적용하기에는 제한적일 수 있으나 임상실험과 치료받은 환자의 예후 등을 조사하여 임상에 적용한다면 각기 다른 표면선량을 요구하는 환자들에게 산란판의 두께변화 만으로도 적절한 표면선량을 부여하는 방법이 될 것으로 생각된다.
연구목적 : 전남대학교병원 치료방사선과에서 가동중인 10MV X-ray를 이용하여 전신 방사선 조사에 필요한 기본적인 선량측정자료를 얻고자 하였다. 대상 및 방법 : 환자 전신이 포함될 수 있는 대형조사면을 얻기 위하여 collimator를 완전히 개방하여 조사방향이 수평이 되게 gantry각을 맞추었다. 방사선 선원에서 환자 중심축까지의 거리가 360cm일 때 최대 기하학적 조사면은 $144cm{\times}144cm$이었다. Polystyrene팬텀과 평행평판형 전리함을 이용하여 깊이선량율과 principal 및 diagonal axis에서 측방선량분포를 측정하였다. 또한 1cm두께의 아크릴판을 팬텀의 전면에서 20cm 떨어진 위치에 놓고 표면 선량의 증가와 최대선량점($d_{max}$)의 변화를 측정하였다. SAD 360cm에서 팬텀의 중심에 측정기 위치를 고정시키고 팬텀의 두께를 12cm에서 30cm까지 변화시키면서 MU당 선량율을 측정하였다. 결과 : SSD 345cm, 조사면 크기 $144cm{\times}144cm$의 조건에서 깊이선량율은 10cm 깊이에서 $78.4{\%}$였고, dmax정은 1.8cm이었다. 1cm두께의 아크릴판을 spoiler로 팬텀에서 20cm 띄우고 사용했을 때 dmax점은 1.8cm에서 0.8cm으로 이동하였고, 표면선량은 $61\%$에서 $94\%$로 증가하였다. 평행 2문 조사시 30cm두께의 팬텀에서 선축상 선량분포의 차이는 $7\%$이내였다. $100\%$ 선량점의 선축이탈거리는 principal axis에서 67cm. diagonal axis에서 80cm이었다. 팬텀의 중심에서 측정된 출력계수로 MU당 선량은, (Dose/MU)=$-0.00178{\times}(T/2)+0.08676$ (T:팬텀 두께(Cm))로 표현되는 직선의 관계식을 나타내었다. 결론 : 1)좌우 대향 2문조사 방법으로 30cm두께의 팬텀에 10MV X-ray를 조사하였을 때 선량분포의 차이는 $7\%$이내로 만족스러운 결과를 보였다. 2) 고에너지 광자선으로 전신방사선 조사시 표면선량 증가를 위하여 beam spotter의 사용이 필요할 것으로 사료된다 3) 측방선량분포곡선에서 principal 및 diagonal axis에 따른 선량분포의 차이가 있어 환자 치료시 고려되어야 할 것으로 생각된다 4) 전신방사선조사시 선량분포는 여러 가지 요인에의하여 달라질 수 있기 때문에 직접적인 방법에 의해 측정된 MU당 선량은 깊이와 직선의 관계식을 보여 실제 치료에 적용될 수 있을 것으로 생각된다. 본 연구에서 얻어진 전신 방사선조사에 관한 기본적 선량측정자료는 AAPM보고서 No. 17에서 권장된 범주에 들었으며 향후 임상에 이용될 수 있을 것으로 생각된다.
The using of compensator is required to adjust the irregular dose distribution due to irregular thickness of the body in Total Body Irradiation. Aluminuim, copper or lead is generally used as compensator. In our study, we would like to introduce a result of the attenuation and compensation effect of radiation use compensator made by duralumin and its clinical use. The thickness of compensator was calculated by the attenustion of radiation, which was measured by polystyrene phantom and ionization chamber(farmer). The compensation effect of radiation was measured by diode detector. All of conditions were set as in real treatment, and the distanc from source to detector was 446 cm. We also made fixation of device to easily attach the compensator to LINAC. Beam spoiler was menufactured and placed on the patient to irradiate sufficient dose to the skin. diode detector were placed on head, neck, chest, umbilicus. pelvis and knee with each their entranced exit points, and datas of dose distribution were evaluated and compared in each points for eleven patients(Feb. 96-Feb. 97). The attenuation rate of irradiation by duralumin compensator was measured as $1.4\%$ in 2mm thickness. The mean attenuation rate was $1.3\%$ per 2mm as increasing the thickness gradually to 50 mm. By using duralunim compensator, dose distribution in each points of body was measured with ${\pm}2.8\%$ by diode detectior. We could easily calculate the thickness of compensator by measuring the attenuation rate of radiation, remarkably reduce the irragularity of dose distribution duo to the thickness of body and magnify the effect of radiation therapy.
전신방사선조사(total body irradiation)는 크게 두 가지가 있는데 첫 번째는 전후 이문대향조사방법(anterior-posterlor total body irradiation)이고 두 번째는 좌우 이문대향조사방법(lateral total body irradiation)이다. 본 병원에서 시행 중인 방법은 환자의 좌우 이문대향조사방법으로서 환자의 측면에서 방사선이 조사되기 때문에 인체의 윤곽에 따른 방사선의 분포가 각 부분에 대해서 다르게 나타나게 된다. 전신 방사선 치료에서 보상체(Compensator)를 사용하여 몸 전체에 균일한 방사선 분포를 만들어내게 한다. 하지만 이런 보상체의 제작은 인체의 모든 부위에서의 수치, 각 부분의 깊이와 길이가 필요한데 특히 머리 부위와 다리 부위 수치에 대한 세밀한 고려가 중요시 되며 또한 조사되는 방사선량의 정확성이 요구된다. 본 연구에서는 기존에 수작업으로 각 부분을 계산하는 방법에서 방사선데이터 및 환자의 각 부분을 데이터화하여 윈도우 환경에서 사용이 용이한 전신방사선조사 계산 프로그램을 개발하였다. 개발된 프로그램은 보상체의 제작 및 방사선량을 계산할 수 있도록 하였다. 본 연구에서는 프로그램 개발을 위하여 IDL 6.0 (Intersys, USA)과 Visual C++ (Microsoft, USA)를 사용하였다. 전신방사선치료시 사용하는 각 에너지별 최대조직선량비(Tissue Maximum Ratio, TMR), 출력인수(output factor), 거 리 역제곱법 칙(Inverse square law), 빔 스포일 러(beam speller), 조사면(field size) 등의 인수를 데 이 터 베이스화함으로써 환자별 보상체의 자동화 제작 및 방사선량 계산을 할 수 있도록 하여 수작업으로 인해 발생할 수 있는 오차와 시간을 줄일 수 있었다. 개발된 전신방사선조사 프로그램을 활용하여 수작업으로 인한 오차를 줄이고 정확한 수치 및 데이터의 적용으로 전신방사선조사에 대한 치료계획을 최적화한다.
방사선 전신조사는 일반적인 방사선 치료와는 달리 환자의 몸 전체를 포함할 수 있는 큰 조사야와 확장된 SAD가 요구되어지기 때문에 치료실이 충분히 커야 하고 전신에 균등한 선량을 주기 위해서는 환자 체표면 윤곽의 불규칙성과 조직 불균질성을 보완해 줄 수 있는 보상체가 필요하며 피부선량을 높여주기 위해서는 적절한 두께의 방사선 산란체를 사용하여야 한다. 또한 치료장치 및 사용 에너지, 총선량, 선량률, 선량분할, 환자의 자세, 정상적인 조직과 장기의 차폐 등도 방사선 전신조사를 위한 중요한 인자들로 알려져 있다. 그리고 방사선 전신조사 치료방법은 환자치료를 위한 준비시간과 실제 치료시간이 길기 때문에 일상 치료환자 일정에 지장을 초래할 수도 있으며 연속되는 치료기간 동안 치료조사야의 정확한 재현이 무엇보다 중요한 것으로 사료된다. 본원에서는 환자의 자세를 굴곡좌위로 함으로써 짧은 거리에서도 환자를 조사야내에 충분히 포함시켰고, 납 보상체를 제작하여 조직결손 부위를 보상하여 전신에 균등한 선량을 줄 수 있었으며 폐 차폐물을 제작하여 폐의 선량을 조절하였다. 치료계획시 환자의 음영을 치료실 벽면에 그려넣음으로써 조사야 재현시 도움이 되도록 하였으며 치료시간을 단축할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.