• Title/Summary/Keyword: Baseline 3

Search Result 2,752, Processing Time 0.031 seconds

Design of a Cascade Adaptive Filter for the Performance sn Detection of Segment (ST세그먼트 검출성능향상을 종속 적응필터의 세계)

  • 박광리;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.517-524
    • /
    • 1995
  • This paper is a study on the design of the cascade adaptive filter (CAF) for baseline wandering elimination in order to enhance the performance of the detection of ST segments in ECG. The CAF using Least Mean Square (LMS) algorithm consists of two filters. The primary adaptive filter which has the cutoff frequency of 0.3Hz eliminates the baseline wandering in raw ECG The secondary adaptive filter removes the remnant baseline wandering which is not eliminated by the primary adaptive filter. The performance of the CAF was compared with the standard filter, the recursive filter, and the adaptive impulse correlated filter (AICF). As a result, the CAF showed a lower signal distortion than the standard filter and the AICF. Also, the CAF showed a better perf'ormance in noise elimination than the standard filter and the recursive filter. In conclusion, considering the characteristics of the noise elimination and the signal distortion, the CAF shows a better performance in the removal of the baseline wandering than the other three Otters and suggests the high performance in the detection of ST segment.

  • PDF

The Effect of Surface Meteorological Measurements on High-precision GPS Positing Determination

  • Wang, Chuan-Sheng;Liou, Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.625-627
    • /
    • 2003
  • In this study, the Global Positioning System (GPS) data collected by the GPS receivers that were established as continuously operating reference stations by Central Weather Bureau and Industrial Technology Research Institute of Taiwan are utilized to investigate the impact of atmospheric water vapor on GPS positioning determination. The surface meteorological measurements that were concurrently acquired by instruments co-located with the GPS receivers include temperature, pressure and humidity data. To obtain the influence of the baseline length on the proposed impact study, four baselines are considered according to the locations of the permanent GPS sites. The length of the shorter baseline is about 66km, while the longer is about 118 km. The results from the studies associated with different baseline lengths and ellipsoid height were compared for the cases with and without a priori knowledge of surface meteorological measurements. The finding based on 66 days measurements is that the surface meteorological measurements have a significant impact on the positioning determination for the longer baseline case. The associated daily maximum differences are 1.1 cm and 1.4 cm for the baseline and ellipsoid height respectively. The corresponding biases are -8.1 mm in length and -7.3 mm in el lipsoid height.

  • PDF

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

A Clinical Study of the Effect of Periodontitis-Medical Gel on Human Gingivitis and Periodontitis (수용성 Periodontitis-Medical Gel이 치은염, 치주염에 미치는 영향)

  • Chai, Jung-Kiu;Choi, Jae-Seong;Park, Ji-Sook;Suh, Jong-Gin;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.1
    • /
    • pp.11-27
    • /
    • 2000
  • The purpose of this study was to evaluate the clinical effects of Dipotassium glycyrrhizinate, Allantoin, Hinokitiol, Cetylpyridinium chloride containing gel($Dentheth^{(R)}$) on periodontitis. 41 patients with sites having pocket depth of 4-6mm were selected for the study. We classified 2 groups which consisted of 21 patients in the test group(exp.) and 20 patients in the control(placebo) respectively. Following a baseline examination, plaque and calculus were removed and then the experimental gel were handed out to the patients and topical application regimens were initiated. During the 4-week experimental period, pocket depth, bleeding on probing, gingival index, plaque index as a clinical parameters were measured in the baseline, 2 weeks, 4 weeks respectively. A questionnaire was delivered to each patients in 2 weeks, 4 weeks respectively. The results were as follows : 1. Probing pocket depth showed a significant difference in the Exp. group compared with the control group in the changes from baseline to 2 weeks(p<0.05), but there was no significant difference between the groups in the changes from baseline to 4 weeks, from 2 weeks to 4 weeks(p<0.05). 2. The Exp. group showed a significant difference compared with the control group in the changes from baseline to 2 weeks, from baseline to 4 weeks, from 2 weeks to 4 weeks in bleeding on probing(p<0.05). 3. The gingival index showed a significant difference compared with the control group in the changes from baseline to 2 weeks, from baseline to 4 weeks, from 2 weeks to 4 weeks after 4 weeks use of a gel(p<0.05). 4. The plaque index showed a significant difference in the Exp. group compared with the control group in the changes from baseline to 2 weeks(p<0.05), but there was no significant difference between the groups in the changes from baseline to 4 weeks, from 2 weeks to 4 weeks(p<0.05). 5. A questionnaire was consisted of 5 kinds as to bleeding, pus discharge, pain, burning sensation, patient's satisfaction and all of the questions showed a significant difference compared with the control group in the changes from 2 weeks to 4 weeks(p<0.05). 6. During the 4-week experimental period, important side-effects were not finded out, but each groups had one patient appealed nausea or discomfort respectively. These results indicate that application of periodontitis medical gel was useful as an additional aid of mechanical treatment.

  • PDF

Leveling the Gamma-ray Spectrometric Data using Baseline Survey (Baseline 탐사를 이용한 항공 방사능 탐사 자료 맞추기)

  • Park, Yeong-Sue;Rim, Hyoungrea;Lim, Mutaek;Shin, Young Hong
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.97-104
    • /
    • 2015
  • KIGAM has surveyed most of the Korean territory since 1982 using airborne gamma-ray spectrometry, and complete the nationwide scale map in the near future. However, since the duration of survey is too long and the conditions of survey is not consistent, the data does not have physical consistency. In addition, the window counts (count/sec) were recorded instead of potassium, uranium and thorium radioelement concentrations. Thus, the data could not be registered to the International Atomic Energy Agency (IAEA) radioelement datum. This limits the usefulness of the data and it is not possible to easily combine surveys into regional compilations or make quantitative interpretations between different survey areas. To solve these problems, we undertook a test baseline survey over Jincheon-Eumseong area, to level the different two sets of data and to map radioelement concentrations. This survey confirms to IAEA radioelement baseline. The method and procedures of data leveling prepared by this study improve the usefulness and usability of the radiometric data, and make it enable to compile the nationwide scale radioelement concentration maps.

A Study on Benefit Sides of Demand Response Customer Baseline with Outdoor Temperature Variable about Load Aggregator (수요관리사업자에 대한 외부온도 변화에 따른 수요반응 CBL의 편익에 관한 연구)

  • Kim, Seong-Cheol;Song, Ha-Na
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.44-50
    • /
    • 2014
  • This paper describes reasonable methods by considering change of outdoor temperature into Customer Baseline Load(CBL) of Demand Resources in Smart Demand Resource Market, which controls peak power demand and maintains reliability of power system. The Smart Demand Resouce Market, which KPX(Korea Power Exchange) implement, is explained and then effects for CBL calculated by considering temperature correction factor are established. Finally, four methods for calculation of CBL are proposed and those results are compared and analyzed.

Success Rate Analysis in GPS Attitude Determination Using a Unscented Kalman Filter (GPS반송파를 이용한 자세결정에서 UKF적용을 통한 성공률 변화 분석)

  • Kwon, Chul-Bum;Chun, Se-Bum;Lee, Eun-Sung;Kang, Tae-Sam;Jee, Gyu-In;Lee, Young-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.3
    • /
    • pp.222-227
    • /
    • 2005
  • Resolving the integer ambiguity of GPS carrier phase measurements is the most important routine in precise positioning. In this paper, success rate is analyzed when using baseline information in the process of determining attitude. The result is verified through the simulation. Determining the initial position for the ambiguity resolution is estimated by using code measurement and baseline constraint. Success rate is estimated using covariance of the formed initial position. UKF has been used to overcome the nonlinear baseline condition during the process so that the higher success rate has been obtained compared with the general attitude determination.

Acoustic theory application in ultra short baseline system for tracking AUV

  • Ji, Daxiong;Liu, Jian;Zheng, Rong
    • Ocean Systems Engineering
    • /
    • v.3 no.1
    • /
    • pp.71-77
    • /
    • 2013
  • The effective tracking area of ultra short baseline (USBL) systems strongly relates to the safety of autonomous underwater vehicles (AUVs). This problem has not been studied previously. A method for determining the effective tracking area using acoustic theory is proposed. Ray acoustic equations are used to draw rays which ascertain the effective space. The sonar equation is established in order to discover the available range of the USBL system and the background noise level using sonar characteristics. The available range defines a hemisphere like enclosure. The overlap of the effective space with the hemisphere is the effective area for USBL systems tracking AUVs. Lake and sea trials show the proposed method's validity.

Damage Detection in Complex Structures using Pattern Recognition of Modal Sensitivity (모드민감도 패턴인식에 의한 복잡한 구조물의 손상발견)

  • 김정태;류연선;노리스스텁스
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.97-105
    • /
    • 1997
  • A methodology to identify a baseline modal model of a complicated 3-D structure using limited structural and modal information is experimentally examined. In the first part, a system's identification theory for the methodology to identify, baseline modal responses of the structure is outlined. Next, an algorithm is designed to build a generic finite element model of the baseline structure and to calibrate the model by using only a set of post-damage modal parameters. In the second part, the feasibility of the methodology is examined experimentally using a field-tested truss bridge far which only post-damaged modal responses were measured for a few vibration modes. For the complex 3-D bridge with many members, we analyzed to identify unknown stiffness parameters of the structure by using modal parameters of the initial two modes of vibration.

  • PDF

Sirius: The KASI-SNU Optical Intensity Interferometer

  • Oh, Junghwan;Trippe, Sascha;Wagner, Jan;Byun, Do-young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.58.3-58.3
    • /
    • 2019
  • Optical intensity interferometry, developed in the 1950s, is a simple and inexpensive method for achieving angular resolutions on microarcsecond scales. Its low sensitivity has limited intensity interferometric observations to bright stars so far. Substantial improvements are possible by using avalanche photodiodes (APDs) as light detectors. We present here the results of laboratory measurements with a prototype astronomical intensity interferometer using APDs in continuous ("linear") detection mode - arguably, the first of its kind. We used two interferometer configurations, one with zero baseline and one with variable baseline. Using a superluminous diode as light source, we unambiguously detected Hanbury Brown-Twiss photon-photon correlations at very high significance. From measuring the correlation as function of baseline, we measured the angular diameter of the light source, in analogy to the measurement of the angular diameter of a star. Our results demonstrate the possibility to construct large astronomical intensity interferometers that can address a multitude of astrophysical science cases.

  • PDF