• Title/Summary/Keyword: Bare Tube

Search Result 68, Processing Time 0.027 seconds

Stimulation Effect of a Soft Ferrite Ceramic Powder on Growth in Plant Cell and Tissue Cultures (연자성 세라믹 분말에 의한 식물세포 및 조직의 생장촉진 효과)

  • Ahn, Jun-Cheul;Kim, Yu-Jung;Park, Chan-Young;Hwang, Baik
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.530-534
    • /
    • 1998
  • The addition of the ceramic powder as state of bare in culture medium has stimulated the growth of Achyranthes japonica in both the disorganized cell and the plantlet. The grwoth rate of Hyoscyamus niger adventitious root and Pylatycodon grandiflorum hairy root was enhanced up to 100 and 250%, respectively, even though Scopolia parviflora hairy root and Hyoscyamus albus adventitious root were not. The ceramic powder has enhanced the growth of H. niger adventitious root even in a test tube immersed into its culture medium to irradiate alone without any direct contact. The ceramic powder seems to have a significant role on both the growth and the physiological action of some plants.

  • PDF

Study on Vacuum Packaging of Field Emission Display (Field Emission Display의 고진공 실장에 관한 연구)

  • Lee, Duck-Jung;Ju, Byeong-Kwon;Jang, Jin;Oh, Myong-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.103-106
    • /
    • 1999
  • In this paper, we suggest the FED packaging technology that have 4mm thickness, using sodalime glass-to-sodalime glass electrostatic bonding. It based on conventional silicon-glass bonding. The silicon film was deposited an around the exhausting hole on FED backside panel. And then, the silicon film of panel was successfully bonded with capping(bare) glass in vacuum environment and the FED panel was vacuum-sealed. In this method, we could achieve more 153 times increased conductance and 200 times increased vacuum efficiency than conventional tube packaging method. The vacuum level in panel, by SRG test, was maintained about low 10$_{-4}$ Torr during above two months And, the light emission was observed to 0.7-inch tubeless packaged FED. Then anode current was 34 $\mu$ A. Emission stability was constantly measured for 10 days.

  • PDF

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Ultimate moment capacity of foamed and lightweight aggregate concrete-filled steel tubes

  • Assi, Issam M.;Qudeimat, Eyad M.;Hunaiti, Yasser M.
    • Steel and Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.199-212
    • /
    • 2003
  • An experimental investigation of lightweight aggregate and foamed concrete contribution to the ultimate strength capacity of square and rectangular steel tube sections is presented in this study. Thirty-four simply supported beam specimens, 1000-mm long, filled with lightweight aggregate and foamed concretes were tested in pure flexural bending to calculate the ultimate moment capacity. Normal concrete-filled steel tubular and bare steel sections of identical dimensions were also tested and compared to the filled steel sections. Theoretical values of ultimate moment capacity of the beam specimens were also calculated in this study for comparison purposes. The test results showed that lightweight aggregate and foamed concrete significantly enhance the load carrying capacity of steel tubular sections. Furthermore, it can be concluded from this study that lightweight aggregate and foamed concretes can be used in composite construction to increase the flexural capacity of the steel tubular sections.

A Study of Cleaning Technology for Zirconium Scrap Recycling in the Nuclear Industry (원자력산업에서 지르코늄 스크랩 재활용을 위한 세정기술에 관한 연구)

  • Lee, Ji-Eun;Cho, Nam-Chan;An, Chang-Mo;Noh, Jae-Soo;Moon, Jong-Han
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.264-271
    • /
    • 2013
  • In this study, we optimized the removal condition of contaminants attached on the scrap surface to recycle the scrap generated from the Zr alloy tube manufacturing process back to the nuclear grade. The main contaminant is remnant of watersoluble cooling lubricant that is used in the pilgering manufacture during the tube production, and it is assumed to be compressed and carbonized on the surface of tube. Zirlo alloy tube of ${\phi}9.50mm$, which has high occurrence frequency of scrap, was selected as the object to be cleaned, and cleaning abilities of reagents were evaluated by measuring the characteristics of contaminants remained and by analyzing the surface of the tube after cleaning process. For evaluation of each cleaning agent, we selected two types of sodium hydroxide series and three types of potassium hydroxide series. Furthermore, to confirm dependence on tempe-rature and ultrasonic intensities, cleaning at the room temperature, $40^{\circ}C$, and $60^{\circ}C$ was conducted, and results showed that higher the cleaning temperature and higher the ultrasonic intensity, better the cleaning effect. As a result of the bare-eye inspection, while the use of sodium hydroxide provided satisfactory condition on the tube surface, the use of potassium hydroxide series provided satisfactory condition on the tube surface only when the ultrasonic intensity was over 120 W. In the cleaning effect analysis using the gravimetric method, cleaning efficiency of sodium hydroxide series was as high as 97.6% ($60^{\circ}C$, 120 W), but since the tube surface condition was poor after the use of potassium hydroxide, the gravimetric method was not appropriate. In the analytical result of surface contaminants on the tube surface, C, O, Ca, and Zr were detected, and mainly C and O dominated the proportion of contaminants. It was also found that the degree of cleaning on the tube affected the componential ratio of C and O; if the degree of cleaning is high, or if cleaning is well-conducted, the proportion of C is decreased, and the proportion of O is increased. Based on these results, optimal cleaning for application in the industry can be expected by categorizing cleaning process into three steps of Alkali cleaning, Rinsing, and Drying and by adjusting cleaning parameters in each step.

Design of Shielded Encircling Send-Receive Type Pulsed Eddy Current Probe Using Numerical Analysis Method

  • Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.505-510
    • /
    • 2013
  • An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in aluminum tube inspection. When bare receive coils located away from the exciter were used, the peak time of the signal did not change although the distance from the exciter increased. This is because the magnetic flux from the exciter coil directly affects the receive coil signal. Therefore, in this work, both the exciter and the sensor coils were shielded in order to reduce the influence of direct flux from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe showed the corresponding increase of the peak time as the sensor distance increased. Ferrite and carbon steel shields were compared and results of the ferrite shielding showed a slightly stronger peak value and a quicker peak time than those of the carbon steel shielding. Simulation results showed that the peak value increased as the defect size (such as depth and length) increased regardless of the sensor location. To decide a proper sensor location, the sensitivity of the peak value to defect size variation was investigated and found that the normalized peak value was more sensitive to defect size variation when the sensor was located closer to the exciter.

Performance Evaluation of CT Using Visible Scintillation Light

  • Kodama, Kiyoyuki;Hashimoto, Masatoshi;Hanada, Takashi;Suzuki, Tamotsu;Ide, Tatsuya;Maruyama, Koichi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.464-467
    • /
    • 2002
  • We propose the use of visible scintillation light for monitoring the X-ray CT in the gantry of a diagnostic CT for its performance test and maintenance works. We placed a disk of bare plastic scintillator disk in the gantry opening area of a helical X-ray CT. When we operated the CT, we could observe the emission of blue scintillation light from the scintillator in a dark room. Visible light was identified under all scanning conditions of diagnostic uses. As a result, we observed the direction and the spread of the incident X-ray in the scintillator. We also observed the change of the part of the scintillator where visible light was generated, and the move that took place associating with the rotation of the X-ray tube during one CT scan. On the basis of the observation, we examined the usefulness of the visible scintillation light as a convenient performance-evaluating tool as well as a maintenance tool of the CT.

  • PDF

Numerical Study on the change of Absorption Characteristics by Change of Flow pattern in the Vertical Falling Film Absorber (수직 액막 흡수관의 유동변화에 따른 흡수성능 변화에 관한 해석적 연구)

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.90-96
    • /
    • 2003
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of LiBr solution. In the present study, the behavior of laminar-wavy falling film in the vertical absorber was studied analytically and experimentally. The change of absorption performance on mean film thickness, wave amplitude, wave celerity was analysed. The heat and mass transfer equations are solved simultaneously to give the temperature and concentration variations at the LiBr solution/refrigeration vapor interface and at the wall. Effects of uniform film, wavy film and film Reynolds number on the heat and mass transfer coefficients have been estimated. The analytical results of the uniform and wavy falling film in the bare tube was higher than experimental result for $Rd_{t}<100$. The absorption performance showed the maximum at the wavy film by the insert device(spring).

  • PDF

Construction of a Low Magnetic Field Standard System Using a Precision Solenoid (정밀솔레노이드를 사용한 저자장 표준시스템 제작)

  • 박포규;손대락;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.150-155
    • /
    • 1992
  • The low magnetic field standard below 1 mT with resolution of 100 nT has been established for the calibration and testing of low field magnetometers. A precision single layered solenoid, which is made of quartz tube and bare copper wire, was constructed in order to generate a precise magnetic field. To improve the field homogeneity in the solenoid, three-current method was employed. The injected current and injection points on the solenoid were optimized by computer simulation. The magnetic field uncertainty in the solenoid was 0.1 % and 0.01 % in the range of ${\pm}5\;cm$ from the center for a single and three-current methods respectively. We also constructed a testing system for the dynamic properties of low field magnetometers.

  • PDF

Relation between brucellosis and husbandry practices in goats in Bangladesh

  • Uddin, Muhammad Jasim;Rahman, Md Siddiqur;Hossain, Mohammad Arif;Akter, Sayeda Hasina;Majumder, S.;Park, Jin-Ho;Song, Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.2
    • /
    • pp.259-267
    • /
    • 2007
  • A study on the relation between some husbandry practices and brucellosis in goats in Bangladesh was conducted at selected areas of Mymensingh and Dhaka district, Bangladesh, from March 2005 to May 2006. Sera from 300 goats were tested by Rose bengal test (RBT), plate agglutination test (PAT), tube agglutination test (TAT) and mercaptoethanol test (MET). Out of the 300 goats, 1.670% (n=5) were positive to RBT and PAT respectively, and 2.0% (n=6) were positive to TAT and 2.33% (n=7) were positive to MET. The prevalence of brucellosis was bigger in goats reared collectively (n=2, 4%) than reared individually (n=5, 2%), and bigger in goats housed with concrete floor (n=2, 4%) than that of bare floor (n=5, 2%). The rate of brucellosis was higher in goats keep separately (n=6, 2.61%) than that of kept with other animals (n=1, 1.43%) especially with cattle. Out of 290 goats from free grazing, 7 were positive but no positive reactor(n=10) was found in non grazing goats. In conclusion, however, seroprevalence of brucellosis had no statistically significant association with rearing type, housing type and grazing or not.