• Title/Summary/Keyword: Bandwidth measurement

Search Result 578, Processing Time 0.033 seconds

QoS Resource management scheme for supporting VoIP Services in All IP Networks (All IP망에서 VoIP서비스를 위한 QoS Resource Management 제공 방안)

  • 윤재구;이병호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.97-100
    • /
    • 2002
  • In this paper, we analyze All IP network architecture and VoIP Service procedure using U Multimedia domain. And, we propose QoS Resource management scheme using with statistical measurement based admission control 8l rate based borrow bandwidth to improve real-time traffic QoS guarantee.

  • PDF

A wide bandwidth sensor for measurement of high-voltage and electric field (광대역 고전압 및 전계 측정용 센서)

  • 백용현;이복희;전덕규
    • Electrical & Electronic Materials
    • /
    • v.5 no.1
    • /
    • pp.89-98
    • /
    • 1992
  • 가스절연개폐장치에서 단로기의 조작시에 발생하는 과도과전압의 측정은 최적절연설계, 신뢰성 향상, 고장탐지 등에 있어 대단히 중요하다. 본 논문은 과도과전압과 시변전계의 정확한 측정이 가능한 용량성 전계센서에 관한 것으로 측정이론, 설계, 교정기술과 실규모 GIS실험장치에서의 과도과전압의 측정에 관한 모의 실험에 대하여 기술하였다. 시제작된 센서의 변환특성은 응답매개변수에 의하여 지배되어지며 센서와 측정계의 주파수대역폭은 수 Hz~ 약 200MHz정도이었다. 실규모 GIS실험장치에 적용하여 과도과전압을 측정한 결과 센서의 우수한 응답특성이 확인되었다.

  • PDF

Development of the Sensor for Measuring the Electric Fields (전계 측정용 센서의 개발)

  • 백용현;이복희;안창환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.630-637
    • /
    • 1991
  • For the measurement of time-varying electric fields and related quantities, a field sensor should be sensitive to the field to be measured, and also designed having an accurate transfer function. In this paper, a theoretical model which adequately describes the operation principle and design of the sensor is presented. A calibration and/or correction technique of the sensor is also studied which enables a precise determination of the response of the sensor to an electric field. As a result, the developed electric field sensor and measuring system are known to be accurate within a bandwidth from a few Hz to 200 MHz. It is found that the sensor can be used directly in the measurement of very fast transient voltages and time-varying electric fields occurring during disconnector operations in a gas-insulated substation. It may be useful also for the study on the electromagnetic environmental parameters.

Equivalent Circuit Model for Four Port Connector System (4포트 커넥터 시스템의 등가회로 변환에 관한 연구)

  • Shim, Min-Kyu;Kim, Jong-Min;Nah, Wan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.

A study on the Observer Design of the Levitation System using Kalman Filter (칼만필터를 이용한 부상시스템 관측기 설계에 관한 연구)

  • Jo, Jeong-Min;Han, Y.J.;Lee, C.Y.;Lee, H.W.;Kang, B.B.;Lee, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1191_1192
    • /
    • 2009
  • The objective of levitation control design is to stabilize a levitation system, or obtain certain transient response, bandwidth, and steady state error. An air gap signal from the each corner is important parameter to design levitation controller. A levitation controller using gap signals with measurement delay time can not make a expected performance. In this paper, a new air gap estimator to improve the performance of levitation controller is proposed. The estimated gap signal which has little measurement delay time is used as a feedback value in the levitation controller.

  • PDF

Investigation of the Polarization Cross-Coupling in Fiber Coils Using White Light Michelson Interferometer (백색광 마이켈슨 간섭계를 이용한 광섬유 고리의 편광 교차결합 측정)

  • Jo, Min-Sik;Do, Jae-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.109-115
    • /
    • 2006
  • The investigation of the polarization cross-coupling in fiber coils was made using white light Michelson interferometer. The white light interferometer has a light source of about 13nm spectral bandwidth and measurement resolution of less than -80dB. The measurement found that the 200m fiber coil has a polarization cross-coupling of about -64dB in average and -46dB in maximum.

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

Neutron Signal Denoising using Edge Preserving Kernel Regression Filter (끝점 신호 보존을 위한 적응 커널 필터를 이용한 중성자 신호 잡음 제거)

  • Park, Moon-Ghu;Shin, Ho-Cheol;Lee, Yong-Kwan;You, Skin
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.439-441
    • /
    • 2005
  • A kernel regression filter with adaptive bandwidth is developed and successfully applied to digital reactivity meter for neutron signal measurement in nuclear reactors. The purpose of this work is not only reduction of the measurement noise but also the edge preservation of the reactivity signal. The performance of the filtering algorithm is demonstrated comparing with well known smoothing methods of conventional low-pass and bilateral filters. The developed method gives satisfactory filtering performance and edge preservation capability.

  • PDF

Study on the High Speed WIM(Weigh-in-Motion) Measurement with Optical Fiber Sensor System (광섬유센서를 이용한 고속주행 트럭의 축중 측정에 관한 연구)

  • 조성규;김기수;배병우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.451-460
    • /
    • 2003
  • In this paper, high speed fiber optic sensor weigh-in motion (WIM) system is proposed. Bragg gratings which have several advantages such as good reproducibility and good multiplicity compare to other optical fiber sensors are used for the system. Fabry-Perot filter for the signal process, which cannot be used in the high speed measurement because of the limitation in fast operation of PZT, is excluded. A new signal processing system which employs bandwidth filter is proposed and bridge type new sensor package design is also proposed. Design of the mold supporter is modified to round shape and then supporting points do not change. The data from the fiber sensors show identical and linear behavior to the axle weight. The proposed fiber optic WIM system is tested in the laboratory and experimented with actual trucks. The new concept of calibration is introduced and calculated by the experiments. The calibrated weight data show good approximations to real axial weights regardless the velocities of the truck.

  • PDF