• 제목/요약/키워드: Balloon-Based

검색결과 96건 처리시간 0.021초

대기 고도에 따른 입자 포집용 관성 임팩터의 설계 및 포집효율 예측 (Numerical Simulation of Impactor Collection Efficiency according to Altitude)

  • 김규호;육세진;안강호
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, the collection efficiency of inertial impactors was numerically simulated by employing the statistical Lagrangian particle tracking(SLPT) model. The SLPT model was proven to be correct in predicting the impactor collection efficiency, when the numerically obtained collection efficiencies were compared with the experimental data of Marple et al.(1987) at normal pressure level and the experimental data of $Marjam{\ddot{a}}ki$ et al.(2000) at low pressure level. Based on the validation results, balloon-borne impactors with the cut-off sizes of $1{\mu}m$, $2.5{\mu}m$, and $10{\mu}m$ were designed. Then, the sampling flowrates of the inertial impactors, required to keep the cut-off sizes constant at different pressures and temperatures, were estimated according to the altitude.

백서의 내장 신경통 연구를 위한 Visceral Pain Model(VPM)의 소개 (Introduction of Visceral Pain Model to Test of Visceral Nociception in the Rats)

  • 이철우
    • The Korean Journal of Pain
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 1995
  • Anlgesic agents against visceral pain typically rely on a noxious chemical irritation of the peritoneum, e. g., acetic acid and phenylquinone writhing test. While useful, this type of assay depends upon an acute inflammation and the release of local alogens. Further, ethical and scientific constraints prevent repeated assessments in a single animal, thereby compounding the difficulty of assessing tolerance development to analgesic agents. To overcome these constraints, Colburn et al. developed a model for mechanical visceral pain model (VPM) based on a repeatable and reversible duodenal distention in the rat. A chronic indwelling intraduodenal balloon catheter is well tolerated and upon inflation produces a writhing response graded in proportion to distention. This response is inhibited by morphine in a dose dependent manner. We found that a model for visceral pain was thought to be a great value.

  • PDF

FALCON code-based analysis of PWR fuel rod behaviour during RIA transients versus new U.S.NRC and current Swiss failure limits

  • Khvostov, G.;Gorzel, A.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3741-3758
    • /
    • 2021
  • Outcomes of the FALCON code analysis-related part of the STARS-ENSI Service Project on Evaluation of the new U.S.NRC RIA Fuel Safety Criteria and Application to the Swiss Reactors are presented. Substantial conservatism of the updated safety limits for high-temperature and PCMI cladding failure, as proposed in the NRC Regulatory Guide RG 1.236, is confirmed. Applicability of the updated failure limits to fuel safety analysis in the Swiss PWRs, as applied to standard fuel designs using UO2 fuel pellets and SRA Zry-4 as cladding materials is discussed. Conducting of new integral RIA tests with irradiated samples using doped- and gadolinia fuel pellets to support appropriate fuel safety criteria for RIA events is recommended.

Optical Design, Test, and alignment of BITSE

  • Kim, Jihun;Choi, Seonghwan;Park, Jongyeob;Yang, Heesu;Baek, Ji-Hye;Kim, Jinhyun;Kim, Yeon-Han;Newmark, Jeffrey S.;Gong, Qian;Gopalswamy, Natchumuthuk
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.57.1-57.1
    • /
    • 2019
  • NASA and Korea Astronomy and Space Science Institute (KASI) have been collaborated to develop the Space solar coronagraph instrument to detect the solar wind speed and corona temperature. As an intermediate stage, BITSE is the Balloon-Borne instrument to prove our proposed technical method which uses a polarized light in 4 different bandwidth wavelengths. In the presentation, the optical design based on the requirements, tests and alignment process for integrating the system are discussed.

  • PDF

디스크 전지를 삼킨 소아에서 내시경적 이물 제거술의 비교 (Comparison of Endoscopic Removal of Disk Batteries in Children)

  • 김정옥;홍은희;최병호;조민현;서혜은;임해리;추미애;황수경;박선민;홍석진;심예지;최병호
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제10권2호
    • /
    • pp.147-156
    • /
    • 2007
  • 목 적: 소아에서 디스크 전지를 삼키는 사고가 증가하고 있다. 식도에 걸린 경우 식도 궤양, 천공, 누공, 종격동염 등 심각한 합병증을 유발할 수 있으므로 즉각 제거해야 한다. 본 연구에서는 디스크 전지의 내시경적 제거에 있어서 기구에 따른 제거 속도의 차이와 안전성을 비교해 봄으로써 가장 빠르고 효율적으로 제거할 수 있는 방법을 찾아보고자 하였다. 방 법: 1997년 7월부터 2007년 6월까지 디스크 전지를 삼키고 경북대학교병원 소아과에 내원하여 내시경적 적출술을 시도한 24명의 환아를 대상으로 하였다. 평균 나이는 1.5세였고 남아가 9명이었다. 내시경 보조기구로써 magnetic extractor와 풍선을 이용하거나 retrieval net을 사용한 경우를 별도로 비교하여 제거에 걸린 시간과 안전성에 차이가 있는지 검토하였다. 결 과: 전지의 직경과 두께가 $20{\times}2$ mm (또는 2 mm) 인 것이 5건이었고 이 중 3예(60%)에서 식도에 걸려 식도 점막 괴사 또는 궤양을 초래하였다. 직경 20 mm 디스크 전지는 직경 10 mm 전지에 비해 식도에 걸려 손상을 초래하는 경우가 유의하게 많았다(p<0.01). 내시경적 제거방법으로 retrieval net을 사용한 경우가 10명으로 평균 1.5분이 소요되었으며 magnetic extractor와 풍선(또는 condom)을 이용한 경우가 6명이었는데 평균 소요 시간이 3.3분 걸려 retrieval net을 사용할 경우 더욱 신속한 제거가 가능하였다(p<0.05). 결 론: 식도의 디스크 전지는 내시경적 응급 상황으로 즉시 내시경으로 신속하고 안전하게 제거할 수 있도록 조치하여야 한다. 저자 등의 경험에 의하면 retrieval net을 이용한 위장내 이물 제거가 더 효과적이었으나, 시술자의 숙련도와 선호도에 따라 magnetic extractor와 풍선을 이용한 방법 또는 retrieval net을 이용한 제거 등을 선택하여 사용할 수 있을 것이다.

  • PDF

뇌피질 이형성증의 자기공명영상소견: 병리적 등급 및 유형과의 연관성에 대하여 (MR Imaging Findings of Cortical Dysplasia of the Brain: Correlation with Pathologic Grades and Subtypes)

  • Bae Ju Kwon;Kee-Hyun Chang;Chun-Kee Chung;Moon Hee Han;Yoon La Choi;Je G. Chi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권1호
    • /
    • pp.47-55
    • /
    • 2003
  • 목적 : 뇌피질 이형성증의 다양한 자기공명영상소견을 유형별로 분류하고 병리적 등급 및 유형과의 연관성을 분석한다. 대상 및 방법 : 수술 후 병리적으로 뇌피질 이형성증이 확진된 97명을 대상으로 하였다. 수술 전 MR 영상을 후향적으로 분석하였으며, 이상 소견의 유무에 따라 MR 양성군과 MR 음성군으로 나누었다. MR 양성군에서는 뇌회와 인접지주막하 공간의 크기, 뇌피질 두께, 피질하백질의 신호 강도, 뇌피질과 백질 경계부의 명확성에 의하여 MR 이상 소견을 분류하였다. 병리적 소견 역시 영상 소견을 모르는 상태에서 후향적으로 분석하였으며, 경도, 중등도, 고도와 비풍선세포형, 풍선세포형으로 나누었다. MR 양성군과 음성군 사이에서 그리고 MR 양성군의 네 가지 유형 내에서 각각 병리적 등급 및 유형의 차이가 있는지 분석하였다. 결과: MR 양성군과 음성군은 각각 39 (40%) 명, 58 (60%) 명이었다. MR 양성군 중 위축형은 13 (33%)명, 피질띠형은 9 (23%)명, 내측 만곡형은 9 (23%)명, 그리고 비특이적 형태는 8 (21%)명이었다. MR 양성군과 음성군 사이에서 병리적 등급은 의미 있는 차이가 없었으나, MR음성군에 비하여 MR 양성군에서 고도의 병리적 등급의 빈도가 높은 경향을 보였으며 또한 풍선 세포형의 빈도 역시 유의하게 높았다. (5% Vs 2l%, p<0.05). 특히 MR 양성군 중에 내측 만곡형은 고도의 병리적 등급과 풍선세포형의 빈도가 각각 78% (7/9), 56% (5/9)인 반면에, 위축형은 경도의 등급과 비풍선세포형의 빈도가 각각 77% (10/13), 100%(13/13)이었다. 결론: 뇌피질이형성증 환자의 MR 영상에서 반 이하에서만 이상 소견을 발견할 수 있었고, 특히 내측 만곡형은 병리적으로 고도의 등급 및 풍선세포형, 그리고 위축형은 경도의 등급 및 비풍선세포형과 높은 연관성을 보여 주었다.

  • PDF

CAD Scheme To Detect Brain Tumour In MR Images using Active Contour Models and Tree Classifiers

  • Helen, R.;Kamaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.670-675
    • /
    • 2015
  • Medical imaging is one of the most powerful tools for gaining information about internal organs and tissues. It is a challenging task to develop sophisticated image analysis methods in order to improve the accuracy of diagnosis. The objective of this paper is to develop a Computer Aided Diagnostics (CAD) scheme for Brain Tumour detection from Magnetic Resonance Image (MRI) using active contour models and to investigate with several approaches for improving CAD performances. The problem in clinical medicine is the automatic detection of brain Tumours with maximum accuracy and in less time. This work involves the following steps: i) Segmentation performed by Fuzzy Clustering with Level Set Method (FCMLSM) and performance is compared with snake models based on Balloon force and Gradient Vector Force (GVF), Distance Regularized Level Set Method (DRLSE). ii) Feature extraction done by Shape and Texture based features. iii) Brain Tumour detection performed by various tree classifiers. Based on investigation FCMLSM is well suited segmentation method and Random Forest is the most optimum classifier for this problem. This method gives accuracy of 97% and with minimum classification error. The time taken to detect Tumour is approximately 2 mins for an examination (30 slices).

Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구 (A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted)

  • 박준기;김선영;김태윤;최계숙;염두석;강동윤;최승오;박지연
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.25-29
    • /
    • 2008
  • 목 적: Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 DIPS를 이용하여 전립선의 위치변화를 관찰하고, 전립선의 움직임에 따른 보정 및 양성자치료에 관한 연구를 하고자 한다. 대상 및 방법: 2008년 4월 이후로 본원에서 양성자치료를 받은 10명의 전립선암환자를 대상으로 하였다. 전립선의 위치변화를 관찰하기위해 치료 전에 전립선에 3개의 Fiducial Gold Marker를 삽입하였고, 전립선의 움직임을 최소화하기 위해 치료 전에 소변을 보고, 매일 정량의 물을 섭취하며, Rectal balloon을 함께 시행하였다. 환자의 처음 치료자세는 CT 모의치료 때와 같고, DIPS (Digital Image Positioning System)를 이용하여 AP, Lat 촬영을 하여 얻은 영상과 치료계획에서 얻은 PA, Lat 영상을 비교하여, Fiducial Gold Marker 위치변화(X, Y, Z) 관찰하였고, 이에 따른 보정 후에 양성자치료를 시행하였다. 결 과: 치료계획에서 얻은 영상과 DIPS를 이용하여 얻은 영상의 각각의 Fiducial Gold Marker의 위치변화 차이는 10명 환자에 있어서 치료 중심을 기준으로 평균 X축: $\pm$0.116 cm, Y축: $\pm$0.19 cm, Z축: $\pm$0.176 cm이었다. 10명의 환자 중 X축으로 최고 RT: 0.24 cm, 최저 RT: 0.04 cm의 위치변화 차이가 나타났고, Y축으로 최고 Sup: 0.42 cm, 최저 Inf: 0.03 cm 위치변화 차이가 나타났고, Z축으로 최고 Ant: 0.35 cm, 최저 Post: 0.05 cm의 위치변화 차이가 관찰되었다. 결 론: 전립선의 움직임을 최소화 하기위해 치료 전에 전처치로 소변을 보고, 매일 정량의 물을 섭취하며, Rectal balloon을 시행하였으나, 모든 환자의 경우에서 전립선에 삽입된 3개의 Fiducial Gold Marker의 매일 움직임을 관찰할 수 있었다. 위 자료를 바탕으로 보다 정확한 치료 중심 설정이 요구되는 양성자치료에서 Gold Marker Matching System의 필요성을 확인할 수 있었으며, 본 연구에서 사용된 DIPS를 이용하여 전립선의 위치변화에 따른 치료 중심을 보정함으로써 보다 정밀한 양성자치료 효과를 향상시킬 수 있을 것으로 사료된다.

  • PDF

Use of Drug-eluting Stents Versus Bare-metal Stents in Korea: A Cost-minimization Analysis Using Population Data

  • Suh, Hae Sun;Song, Hyun Jin;Jang, Eun Jin;Kim, Jung-Sun;Choi, Donghoon;Lee, Sang Moo
    • Journal of Preventive Medicine and Public Health
    • /
    • 제46권4호
    • /
    • pp.201-209
    • /
    • 2013
  • Objectives: The goal of this study was to perform an economic analysis of a primary stenting with drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients with acute myocardial infarction (AMI) admitted through an emergency room (ER) visit in Korea using population-based data. Methods: We employed a cost-minimization method using a decision analytic model with a two-year time period. Model probabilities and costs were obtained from a published systematic review and population-based data from which a retrospective database analysis of the national reimbursement database of Health Insurance Review and Assessment covering 2006 through 2010 was performed. Uncertainty was evaluated using one-way sensitivity analyses and probabilistic sensitivity analyses. Results: Among 513 979 cases with AMI during 2007 and 2008, 24 742 cases underwent stenting procedures and 20 320 patients admitted through an ER visit with primary stenting were identified in the base model. The transition probabilities of DES-to-DES, DES-to-BMS, DES-to-coronary artery bypass graft, and DES-to-balloon were 59.7%, 0.6%, 4.3%, and 35.3%, respectively, among these patients. The average two-year costs of DES and BMS in 2011 Korean won were 11 065 528 won/person and 9 647 647 won/person, respectively. DES resulted in higher costs than BMS by 1 417 882 won/person. The model was highly sensitive to the probability and costs of having no revascularization. Conclusions: Primary stenting with BMS for AMI with an ER visit was shown to be a cost-saving procedure compared with DES in Korea. Caution is needed when applying this finding to patients with a higher level of severity in health status.

전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가 (USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN)

  • 박도근;최병기;김진만;이동훈;송기원;박영환
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.127-135
    • /
    • 2014
  • 목 적 : 전립선 암의 방사선 치료 시 컴퓨터 단층촬영 영상만을 이용하여 타겟 및 정상장기의 체적을 정의하기에는 제약성이 따른다. 이러한 제약성을 보완해주기 위하여 연부조직 대조도가 우수한 자기공명영상 장치가 사용되고 있다. 그러나 부정확한 CT/MRI 영상의 융합은 정확한 타겟 설정에 불확실성이 따르게 되며 정상장기의 불필요한 선량이 입사되어 부작용을 초래 할 수 있다. 이러한 불확실성을 줄이기 위해 본원에서는 CT/MRI영상 융합 시 모의 치료 과정과 동일한 고정용구와 자세로 환자를 셋업하여 MRI(Planning MRI)영상을 획득하고 있으며, 본 연구에서는 진단용 MRI영상과 Planning MRI영상을 비교 분석하여 Planning MRI의 유용성을 평가하고자 한다. 대상 및 방법 : 본원에서 2011년 8월부터 2013년 7월까지 전립선 암으로 진단을 받고 Non-hormone, Definitive RT 70 Gy/28 fx을 처방받은 10명의 환자를 대상으로 하였다. 모의 치료 후 30분 뒤에 MRI영상을 획득하였으며, 획득 된 CT/MRI영상은 뼈를 중심으로 Philips pinnacle v9.2를 이용하여 융합하였다. 전립선 Balloon tube의 유무에 따른 전립선의 변화를 측정하기 위하여 Planning MRI, 진단용 MRI영상에서의 전립선 체적을 측정 비교하였으며, 각각의 영상에서 전립선의 모양의 변화를 측정하기 위해 전립선의 중심에서 상하, 앞뒤, 좌우방향에서의 직경을 측정 비교하였다. 결 과 : Planning MRI, 진단용 MRI영상에서의 전립선 체적을 비교한 결과 각각 평균 $25.01cm^3$(범위 $15.84-34.75cm^3$), $25.05cm^3$(범위 $15.28-35.88cm^3$)의 결과를 얻었다. Planning MRI 대비 진단용 MRI는 0.12 % 증가로 그 차이는 크지 않다는 것을 알 수가 있었다. 하지만 Planning MRI를 기준으로 Transition zone 방향으로 총 $7.46cm^3$(29 %) 체적의 증가가 있었으며, Peripheral zone 방향으로 $8.52cm^3$(34 %)의 체적 감소가 있었다. 전립선 중심의 2차원 영상에서의 상하, 앞뒤, 좌우방향의 직경을 측정한 결과 Planning MRI에서 평균 3.82cm, 2.38cm, 4.59cm의 값을 나타냈으며, 진단용 MRI에서는 평균 3.37cm, 2.76cm, 4.51cm의 값을 알 수 있었다. Planning MRI 기준으로 앞뒤 방향으로 0.38cm(13 %)감소하였으나 좌우 방향 0.08cm(1.6 %), 상하방향 0.45cm(13 %)가 증가되었다. 결 론 : 본 연구의 결과를 바탕으로 Planning MRI와 진단용 MRI에서의 전립선의 총 체적은 큰 차이를 보이지 않았지만 직장에 전립선 Balloon tube 삽입으로 인한 전립선의 모양 및 부분 체적의 변화를 알 수가 있었다. 따라서 CT/MRI 영상 융합 시 Planning MRI영상을 이용한다면 진단용 MRI영상과 비교하여 Transition zone에 증가하는 체적만큼 손실 없이 타겟을 CTV에 포함시킬 수 있으며, Balloon으로 인한 Peripheral zone 체적의 감소를 더 명확히 구분하여 직장에 전달되는 방사선량을 줄일 수 있을 것이다. 이에 본 저자는 전산화 치료 계획에서의 CT/MRI영상 융합 시 모의 치료 과정과 동일한 고정용구와 자세를 재현하여 MRI영상을 획득하는 것이 유용할 것이라 사료된다.