• Title/Summary/Keyword: Backup system

Search Result 314, Processing Time 0.023 seconds

A Study on the Optimal System Sizing of the Standalone Photovoltaic Power Generation System for Uninterruptible Power Supply (독립형 태양광 발전 시스템의 무정전 전력공급을 위한 시스템 용량 최적 선정에 관한 연구)

  • Kim, Ki-Young;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.77-85
    • /
    • 2018
  • Renewable energy has been increasingly used and widely acclaimed as one of the solutions to rampant environmental problems. Among numerous kinds of renewable sources, the penetration rate of the PV system is relatively higher than that of others due to ease of installation. However, one disadvantage of the PV system is its dependence on weather condition. The PV system is especially critical when it is used for standalone systems because it cannot operate when the power generated from a PV module is not enough. Therefore, PV systems are often used with an energy storage system, such as batteries, to store backup energy when the weather condition is insufficient to supply power to the system. Blackout time can be reduced by increasing the size of the energy storage system, but it is a trade-off with system cost. In this work, optimal sizing of a standalone PV system is proposed to supply power to the system without blackout. The sizing of PV modules and batteries is performed by a simulation based on actual irradiation data collected during the past five years. The Life cycle costing of each system is evaluated to determine an optimal set of PV modules and batteries among several different combinations. The standalone PV system designed by the proposed method can supply power to the system with no interruption as long as the weather condition is similar to those of the past five years.

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

Real-time monitoring of berthing/deberthing operations process for entering/leaving vessels using VTS system in Busan northern harbor, Korea (부산 북항에서 VTS 시스템에 의한 출입항 선박의 접이안 작업과정의 실시간 모니터링)

  • Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.3
    • /
    • pp.165-176
    • /
    • 2009
  • The process of berthing/deberthing operations for entering/leaving vessels in Busan northern harbor was analyzed and evaluated by using an integrated VTS(vessel traffic service) system installed in the ship training center of Pukyong National University, Busan, Korea. The integrated VTS system used in this study was consisted of ARPA radar, ECDIS(electronic chart display and information system), backup(recording) system, CCTV(closed-circuit television) camera system, gyro-compass, differential GPS receiver, anemometer, AIS(automatic identification system), VHF(very high frequency) communication system, etc. The network of these systems was designed to communicate with each other automatically and to exchange the critical information about the course, speed, position and intended routes of other traffic vessels in the navigational channel and Busan northern harbor. To evaluate quantitatively the overall dynamic situation such as maneuvering motions for target vessel and its tugboats while in transit to and from the berth structure inside a harbor, all traffic information in Busan northern harbor was automatically acquired, displayed, evaluated and recorded. The results obtained in this study suggest that the real-time tracking information of traffic vessels acquired by using an integrated VTS system can be used as a useful reference data in evaluating and analyzing exactly the dynamic situation such as the collision between ship and berth structure, in the process of berthing/deberthing operations for entering/leaving vessels in the confined waters and harbor.

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

A Real-Time Embedded Task Scheduler considering Fault-Tolerant (결함허용을 고려한 실시간 임베디드 태스크 스케줄러)

  • Jeon, Tae-Gun;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.7
    • /
    • pp.940-948
    • /
    • 2011
  • In this paper, we design and implement a task scheduler that considers real-time and fault tolerance in embedded system with a single processor. We propose a method how it can meet the deadlines of periodic tasks using RMS and complete the execution of aperiodic tasks by calculating surplus times from a periodic task set. And we describe a method how to recover of a transient fault task by managing backup time. We propose an important level of periodic tasks that can control the response time of periodic and aperiodic tasks. Finally, we analyse and evaluate the proposed methods by simulation.

DC Microgrid Operational Method for Enhanced Service Reliability Using DC Bus Signaling

  • Hwang, Pyeong-Ik;Jang, Gilsoo;Pyo, Gi-Chan;Han, Byung-Moon;Moon, Seung-Il;Ahn, Seon-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.452-464
    • /
    • 2015
  • This paper proposes a DC microgrid operational strategy and control method for improved service reliability. The objective is to supply power to as many non-critical loads as possible, while providing an uninterrupted power supply to critical loads. The DC bus signaling method, in which DC voltage is an information carrier, is employed to implement the operational strategy in a decentralized manner. During grid-connected operation, a grid-tied converter balances the power of the microgrid by controlling the DC voltage. All loads are connected to the microgrid, and operate normally. During islanded operation, distributed generators (DGs), a backup generator, or an energy storage system balances the power. However, some non-critical loads may be disconnected from the microgrid to ensure the uninterrupted power supply to critical loads. For enhanced service reliability, disconnected loads can be automatically reconnected if certain conditions are satisfied. Control rules are proposed for all devices, and detailed microgrid operational modes and transition conditions are then discussed. Additionally, methods to determine control parameter settings are proposed. PSCAD/EMTDC simulation results demonstrate the performance and effectiveness of the proposed operational strategy and control method.

Design and Development of a Medical Education System Using Information Technology: A Case Report from the Pusan National University School of Medicine (정보기술을 활용한 의학교육시스템의 설계와 개발: 부산대학교 의학전문대학원 사례)

  • Im, Sun Ju;Lee, Sang Yeoup;Baek, Sun Yong;Woo, Jae Seok;Kam, Beesung
    • Korean Medical Education Review
    • /
    • v.16 no.1
    • /
    • pp.16-24
    • /
    • 2014
  • The development of information technology (IT) has led to changes in medical education. IT has been used for e-learning and e-teaching, e-assessment, e-logistics, and e-administration. Pusan National University School of Medicine has developed its own educational information system using IT to support students' learning and assessment and to manage curricular activities. Based on our experience, we propose six suggestions for designing new software, specifically regarding simplifying the design for users, communication with the programmer, a rapid cycle from design to implementation, orientation support for users, backup and security support, and obtaining patents. Collaborating with the Department of Medical Informatics within the School of Medicine has advantages, and an alliance among medical schools can simplify the development of software. In any case, curricular innovation should precede the introduction of technology because all technologies should support curricular goals.

A Design and Implementation of Image Maintenance Using Base on Grid of the Decentralized Storage System (GRID 기반의 분산형 의료영상 저장시스템 설계 및 구현)

  • Kim, Sun-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Modern hospitals have been greatly facilitated with information technology (IT) such as hospital information system (HIS). One of the most prominent achievements is medical imaging and image data management so-called Picture Archiving and Communication Systems (PACS). Due to inevitable use of diagnostic images (such as X-ray, CT, MRI), PACS made tremendous impact not only on radiology department but also nearly all clinical departments for exchange and sharing image related clinical information. There is no doubt that better use of PACS leads to highly efficient clinical administration and hospital management. However, due to rapid and widespread acceptance of PACS storage and management of digitized image data in hospital introduces overhead and bottleneck when transferring images among clinical departments within and/or across hospitals. Despite numerous technical difficulties, financing for installing PACS is a major hindrance to overcome. In addition, a mirroring or a clustering backup can be used to maximize security and efficiency, which may not be considered as cost-effective approach because of extra hardware expenses. In this study therefore we have developed a new based on grid of distributed PACS in order to balance between the cost and network performance among multiple hospitals.

  • PDF

Improvement and Evaluation of Portable Electrical Ventilator (전기 구동 이동형 인공호흡기의 개선 및 평가)

  • Ko, S.H.;Choi, N.B.;Kim, D.W.;Lee, S.H.;Oh, Y.S.;Lee, K.H.;Lee, S.H.;Lee, T.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.149-150
    • /
    • 1998
  • We have developed electrically driven portable ventilator and evaluated through in-vitro and in-vivo test. Ventilator is consists of DC servo motor(Kollmorgen), piston and ball screw, sensing system, power system with backup battery and micro controller. For the precise and stable volume control, the dynamic brake and the PI speed control loop is employed. The main functions are as followers; control, control+sigh, control/assist, control/assist+sigh and SIMV. The animal experiment showed stable performance when it is operated in control mode.

  • PDF

Design of Asynchronous Non-Volatile Memory Module Using NAND Flash Memory and PSRAM (낸드 플래시 메모리와 PSRAM을 이용한 비동기용 불휘발성 메모리 모듈 설계)

  • Kim, Tae Hyun;Yang, Oh;Yeon, Jun Sang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.3
    • /
    • pp.118-123
    • /
    • 2020
  • In this paper, the design method of asynchronous nonvolatile memory module that can efficiently process and store large amounts of data without loss when the power turned off is proposed and implemented. PSRAM, which takes advantage of DRAM and SRAM, was used for data processing, and NAND flash memory was used for data storage and backup. The problem of a lot of signal interference due to the characteristics of memory devices was solved through PCB design using high-density integration technology. In addition, a boost circuit using the super capacitor of 0.47F was designed to supply sufficient power to the system during the time to back up data when the power is off. As a result, an asynchronous nonvolatile memory module was designed and implemented that guarantees reliability and stability and can semi-permanently store data for about 10 years. The proposed method solved the problem of frequent data loss in industrial sites and presented the possibility of commercialization by providing convenience to users and managers.