CHARACTERISTICS EVALUATION AND GROWTH OF $BI_4GE_3O_{12}$ SINGLE CRYSTAL BY CZOCHRALSKI METHOD

  • Cho, Yun-Ho;Kim, Yong-Kyun;Lee, Woo-Gyo;Kang, Byoung-Hwi;Kim, Jong-Kyung;Lee, Dong-Hoon;Park, Jae-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.83-86
    • /
    • 2009
  • The single crystal scintillator of bismuth germinate ($Bi_4Ge_3O_{12}$:BGO) was successfully grown by the conventional Czochraski technique. The characteristics of the grown BGO were evaluated and presented on the excitation, emission responses and energy spectra of the $\gamma$-rays from $^{241}Am$, $^{133}Ba$, $^{57}Co$, $^{22}Na$, $^{137}Cs$ and $^{54}Mn$ radio-isotopes. The energy resolution of grown BGO, $\Delta$E/E, was estimated to be 12.1% at 662 keV of $\gamma$-ray for $^{137}Cs$ nuclide. Compared to the commercial BGO crystal, we confirmed that the grown BGO has a good performance and is comparable to reference one.

Growth of ${\gamma}-6Bi_2O_3{\cdot}GeO_2$ Single Crystals by EFG Method (EFG법에 의한 ${\gamma}-6Bi_2O_3{\cdot}GeO_2$)

  • ;;Kei-Miyamoto
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.1 no.2
    • /
    • pp.34-45
    • /
    • 1991
  • The fundamental conditions for growing $r-6Bi_2O_3{\cdot}GeO_2$ (BGO) single crystal plates by EFG (Edge -defined Film-fed Growth) method, were investigated and the characterization, quality test were carried out for obtained BGO single crystal plates. The optimum growing conditions determined in this study were as follows: ${\cdot}$ temperature gradient: 22^{\circ}C/cm

  • PDF

Growth of Optical Quality $Bi_{12}GeO_{20}$ Crystals and Preparation of SAW-Filter ($Bi_{12}GeO_{20}$단결정 육성 및 표면탄성파 소자 제조)

  • 이태근;정수진
    • Korean Journal of Crystallography
    • /
    • v.2 no.2
    • /
    • pp.32-40
    • /
    • 1991
  • The effects of compositional variation, rotation speel and pulling rate on the growth of optical quality Bi120e02(1 crystals were examined. It was found to flatten the shape of crystal-melt interface for yowing a single crystals less than about 30mm in diameter at the rotation speed of 50rpm. Diameter of crystals with flat interface was increased as the pulling rate. The precipitation of Bi40e3012 phase set limits to pulling rate of BGO crystals. Precipitate-free BGO crystals were grown under pulling rate of 2mm l hr which released the stress resulted from too hi어 Pulling rate, and from 6. IBi203·GeO2 batch composition obtained by addition of 0.1 mole Bi203 into Bi-deficient melts to fill up the deficiency resulted from gradual volatilization of Bi2O). The pale-yellow colored crystals had good quality in that dislocation density was less than 103pits/cm, and it also exhibited transmittance of 70% and optical activity of 23°/mm. and SAW velosity was measured 1700m/sec on 111 cut 110 propagating BGO crystals. The SAW filter with electrode thickness of 9.8um was fabricated by using the electron beam and dry etching technique, it makes Bi12GeO20 devices intersting for color TV IF with half device size.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.